Design of microfission chamber for ITER operations

被引:15
作者
Ishikawa, Masao [1 ]
Kondoh, Takashi [1 ]
Nishitani, Takeo [1 ]
Kusama, Yoshinori [1 ]
机构
[1] Japan Atom Energy Agcy, Fus Res & Dev Directorate, Naka, Ibaraki 3110193, Japan
关键词
fusion reactor design; fusion reactor operation; Monte Carlo methods; neutron transport theory; plasma diagnostics; Tokamak devices;
D O I
10.1063/1.2969286
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Microfission chambers (MFCs) are one of the most important diagnostics for measuring neutron source strength in ITER. Using MFCs for high-power operations (fusion power of 100 kW-1 GW) and for low-power operations (< 100 kW) in combination is one way to fulfill the target measurement requirements of ITER. The MFCs for high-power operations will be installed behind blanket modules in both the upper and lower outboard regions of the vacuum vessel so as to be insensitive to changes in the position of the plasma. For low-power operations, one possible location of MFCs is inside the equatorial (EQ) port. The effect of streaming neutrons and of changes in the position of the plasma on the responses of MFCs is estimated based on a neutron Monte Carlo calculation using the MCNP Version 5 code. Results suggest that the effect of streaming neutrons should be taken into account if the MFCs for high-power operations are installed closer than 20 cm to the gap between blanket modules. It has also been found for MFCs of low-power operations that the averaged output of the MFCs installed at the top and bottom of the EQ port is sensitive to horizontal plasma shifts but not to vertical shifts. This finding suggests that corrections based on the position of the plasma center will be needed for the absolute measurement of neutron source strength.
引用
收藏
页数:4
相关论文
共 6 条
[1]  
[Anonymous], LAUR031987 LOS AL NA
[2]   Chapter 7: Diagnostics [J].
FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein, Netherlands ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 .
Nucl Fusion, 2007, 6 (S337-S384) :S337-S384
[3]   A COUNTING-CAMPBELLING NEUTRON MEASUREMENT SYSTEM AND ITS EXPERIMENTAL RESULTS BY TEST REACTOR [J].
ENDO, Y ;
ITO, T ;
SEKI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :714-717
[4]  
FORREST B, 2004, INDCNDC451
[5]   Neutron monitor using microfission chambers for the international Thermonuclear Experimental Reactor [J].
Nishitani, T ;
Kasai, S ;
Johnson, LC ;
Ebisawa, K ;
Walker, C ;
Ando, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1141-1144
[6]   Development of in-vessel neutron monitor using micro-fission chambers for ITER [J].
Yamauchi, M ;
Nishitani, T ;
Ochiai, K ;
Morimoto, Y ;
Hori, J ;
Ebisawa, K ;
Kasai, S ;
Walker, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03) :1730-1734