Quantitative myocardial CT perfusion: a pictorial review and the current state of technology development

被引:33
|
作者
So, Aaron [1 ]
Lee, Ting-Yim [1 ]
机构
[1] Robarts Res Inst, Imaging Program, Lawson Hlth Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
关键词
Myocardial CT perfusion; Quantitative; Tracer kinetic modeling; Beam hardening correction; Dual-energy CT; Radiation dose reduction; Iterative reconstruction; CORONARY-ARTERY STENOSIS; COMPUTED-TOMOGRAPHY; BLOOD-FLOW; MODEL; QUANTIFICATION; ANGIOGRAPHY; BRAIN; TIME; REDUCTION; TRANSPORT;
D O I
10.1016/j.jcct.2011.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality, and is associated with substantial and increasing resource burden. A combined physiologic and anatomic assessment may improve identification of patients with CAD who would benefit from revascularization and reduce unnecessary diagnostic and interventional procedures. Cardiovascular computed tomography (CT) has the potential to provide a comprehensive evaluation of CAD in a single setting. Although coronary CT angiography has been widely implemented for clinical use, the application of myocardial CT perfusion (CTP) has been relatively restricted because of a few limitations, such as beam hardening and the high radiation dose delivered. In this article, we first review the fundamental basis of the qualitative, semiquantitative, and quantitative techniques for myocardial CTP and discussed the strength and weakness of each approach. Beam-hardening correction for myocardial CTP with image-based method and dual-energy CT are then discussed with example cases demonstrating the effectiveness of each method. Initial experiences suggest both techniques can reduce beam-hardening artifact to a satisfactory extent. An overview on dose reduction technologies, such as prospective ECG triggering and iterative reconstruction for myocardial CTP, is also provided. Preclinical studies suggest it is feasible to perform low-dose quantitative myocardial CTP without affecting perfusion measurement. Finally, the impact of scan length on myocardial CTP is addressed. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:467 / 481
页数:15
相关论文
共 50 条
  • [31] Relation between quantitative coronary CTA and myocardial ischemia by adenosine stress myocardial CT perfusion
    Alexander R. van Rosendael
    Lucia J. Kroft
    Alexander Broersen
    Jouke Dijkstra
    Inge J. van den Hoogen
    Erik W. van Zwet
    Jeroen J. Bax
    Michiel A. de Graaf
    Arthur J. Scholte
    Journal of Nuclear Cardiology, 2017, 24 : 1253 - 1262
  • [32] Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model
    Scherer, Kai
    Hammel, Johannes
    Sellerer, Thorsten
    Mechlem, Korbinian
    Renger, Bernhard
    Baehr, Andrea
    Kupatt, Christian
    Hinkel, Rabea
    Herzen, Julia
    Pfeiffer, Franz
    Rummeny, Ernst
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [33] Quantitative myocardial perfusion 82Rb-PET assessed by hybrid PET/coronary-CT: Normal values and diagnostic performance
    Freitag, Martin T.
    Bremerich, Jens
    Wild, Damian
    Haaf, Philip
    Zellweger, Michael J.
    Caobelli, Federico
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 464 - 473
  • [34] Technical development in cardiac CT: current standards and future improvements-a narrative review
    Toia, Patrizia
    La Grutta, Ludovico
    Sollami, Giulia
    Clemente, Alberto
    Gagliardo, Cesare
    Galia, Massimo
    Maffei, Erica
    Midiri, Massimo
    Cademartiri, Filippo
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (06) : 2018 - 2035
  • [35] From Inception to 2020: a Review of Dynamic Myocardial CT Perfusion Imaging
    Sujana Balla
    Koen Nieman
    Current Cardiovascular Imaging Reports, 2021, 14
  • [36] Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging
    So, Aaron
    Imai, Yasuhiro
    Nett, Brian
    Jackson, John
    Nett, Liz
    Hsieh, Jiang
    Wisenberg, Gerald
    Teefy, Patrick
    Yadegari, Andrew
    Islam, Ali
    Lee, Ting-Yim
    MEDICAL PHYSICS, 2016, 43 (08) : 4821 - 4832
  • [37] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Bucher, Andreas M.
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Wolla, Christopher D.
    Canstein, Christian
    McQuiston, Andrew D.
    Krazinski, Aleksander W.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3215 - 3222
  • [38] The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT
    Kennedy, John A.
    Brodov, Yafim
    Weinstein, Adam L.
    Israel, Ora
    Frenkel, Alex
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 236 - 245
  • [39] Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT
    Isola, A. A.
    Schmitt, H.
    van Stevendaal, U.
    Begemann, P. G.
    Coulon, P.
    Boussel, L.
    Grass, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18) : 5925 - 5947
  • [40] Promote quantitative ischemia imaging via myocardial perfusion CT iterative reconstruction with tensor total generalized variation regularization
    Gu, Chengwei
    Zeng, Dong
    Lin, Jiahui
    Li, Sui
    He, Ji
    Zhang, Hao
    Bian, Zhaoying
    Niu, Shanzhou
    Zhang, Zhang
    Huang, Jing
    Chen, Bo
    Zhao, Dazhe
    Chen, Wufan
    Ma, Jianhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12)