Effects of radiation and their consequences for the performance of the forward calorimeters in the CMS experiment

被引:6
作者
Akchurin, N
Ayan, AS
Bencze, GL
Dumanoglu, I
Eskut, E
Fenyvesi, A
Ferrando, A
Gavrilov, V
Hajdu, C
Josa, MI
Kayis, A
Kolosov, V
Kuleshov, S
Kuzucu-Polatoz, A
Litvintsev, D
Lobban, O
Merlo, JP
Molnár, J
Onel, Y
Önengüt, G
Osborne, D
Özdes-Koca, N
Stolin, V
Sulak, L
Ulyanov, A
Uzunian, S
Vesztergombi, G
Wigmans, R [1 ]
Winn, D
Yumashev, A
Zalan, P
Zeyrek, M
机构
[1] Texas Tech Univ, Lubbock, TX 79409 USA
[2] Univ Iowa, Iowa City, IA USA
[3] RMKI, KFKI, Budapest, Hungary
[4] Cukurova Univ, Adana, Turkey
[5] ATOMKI, Debrecen, Hungary
[6] CIEMAT, E-28040 Madrid, Spain
[7] ITEP, Moscow, Russia
[8] Boston Univ, Boston, MA 02215 USA
[9] Fairfield Univ, Fairfield, CT 06430 USA
[10] Middle E Tech Univ, TR-06531 Ankara, Turkey
基金
匈牙利科学研究基金会;
关键词
Colliding beam accelerators - Photons - Radiation detectors - Radiation effects;
D O I
10.1016/S0168-583X(01)00852-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The experiments at the Large Hadron Collider (LHC) will have to deal with unprecedented radiation levels. In the large-rapidity regions, close to the beam pipe, these levels reach megagrays per year. The detectors to be installed in these regions, the HF Calorimeters, are designed to operate under these conditions, In this paper, we describe the results of studies in which a prototype calorimeter was exposed to radiation of the type and intensity expected at the LHC. These studies made it possible to estimate the effects of this radiation on the response and the resolution of the calorimeter as a function of time during LHC operation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:66 / 78
页数:13
相关论文
共 10 条
[1]   EFFECTS OF RADIATION-DAMAGE ON SCINTILLATING FIBER CALORIMETRY [J].
ACOSTA, D ;
DESALVO, R ;
HARTJES, FG ;
HENRIQUES, A ;
LINSSEN, L ;
MAIO, A ;
ONG, B ;
PAAR, HP ;
PEREIRA, M ;
SCHEEL, CV ;
SIVERTZ, M ;
SONDEREGGER, P ;
WIGMANS, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :116-132
[2]   Electromagnetic shower profile measurements in iron with 500 MeV electrons [J].
Akchurin, N ;
Ayan, AS ;
Conan, N ;
Dumanoglu, I ;
Fontaine, A ;
Merlo, JP ;
Muller, A ;
Rinolfi, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (03) :303-313
[3]   On the differences between high-energy proton and pion showers and their signals in a non-compensating calorimeter [J].
Akchurin, N ;
Ayan, S ;
Bencze, GL ;
Chikin, K ;
Cohn, H ;
Doulas, S ;
Dumanoglu, I ;
Eskut, E ;
Fenyvesi, A ;
Ferrando, A ;
Fouz, MC ;
Ganel, O ;
Gavrilov, V ;
Gershtein, Y ;
Hajdu, C ;
Iosifidis, J ;
Josa, MI ;
Kayis, A ;
Khan, A ;
Kim, SB ;
Kolosov, V ;
Kuleshov, S ;
Kuzucu-Polatoz, A ;
Langland, J ;
Litvintsev, D ;
Merlo, JP ;
Molnar, J ;
Nikitin, A ;
Onel, Y ;
Onengut, G ;
Osborne, D ;
Ozdes-Koca, N ;
Ozturk, H ;
Penzo, A ;
Pesen, E ;
Podrasky, V ;
Rosowsky, A ;
Salicio, JM ;
Sanzeni, C ;
Sever, R ;
Silvestri, H ;
Stolin, V ;
Sulak, L ;
Sullivan, J ;
Ulyanov, A ;
Uzunian, S ;
Vesztergombi, G ;
Wigmans, R ;
Winn, D ;
Winsor, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 408 (2-3) :380-396
[4]   Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection [J].
Akchurin, N ;
Ayan, S ;
Bencze, GL ;
Chikin, K ;
Cohn, H ;
Doulas, S ;
Dumanoglu, I ;
Eskut, E ;
Fenyvesi, A ;
Ferrando, A ;
Fouz, MC ;
Ganel, O ;
Gavrilov, V ;
Gershtein, Y ;
Hajdu, C ;
Iosifidis, J ;
Josa, MI ;
Khan, A ;
Kim, SB ;
Kolosov, V ;
Kuleshov, S ;
Langland, J ;
Litvintsev, D ;
Merlo, JP ;
Molnar, J ;
Nikitin, A ;
Onel, Y ;
Onengut, G ;
Osborne, D ;
OzdesKoca, N ;
Penzo, A ;
Pesen, E ;
Podrasky, V ;
Rosowsky, A ;
Salico, JM ;
Sanzeni, C ;
Sever, R ;
Silvestri, H ;
Stolin, V ;
Sulak, L ;
Sullivan, J ;
Ulyanov, A ;
Uzunian, S ;
Vesztergombi, G ;
Wigmans, R ;
Winn, D ;
Winsor, R ;
Yumashev, A ;
Zalan, P ;
Zeyrek, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3) :202-226
[5]  
*CMS COLL, 1997, 9731 CERNLHCC CMS CO
[6]  
DUMANOGLU I, 2001, 200120 CMS CERN
[7]   VERY HARD RADIATION RESISTANT AND ULTRA-FAST CALORIMETRY [J].
GORODETZKY, P ;
GROSDIDIER, B ;
LAZIC, D .
RADIATION PHYSICS AND CHEMISTRY, 1993, 41 (1-2) :253-261
[8]   RADIATION-INDUCED DEFECTS IN GLASSES - ORIGIN OF POWER-LAW DEPENDENCE OF CONCENTRATION ON DOSE [J].
GRISCOM, DL ;
GINGERICH, ME ;
FRIEBELE, EJ .
PHYSICAL REVIEW LETTERS, 1993, 71 (07) :1019-1022
[9]   RADIATION STABILITY OF PLASTIC SCINTILLATORS AND WAVELENGTH SHIFTERS [J].
HOLM, U ;
WICK, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :579-583
[10]  
NELSON WR, 1978, EGS, V4