Study on photocatalytic oxidation for determination of the low chemical oxygen demand using a nano-TiO2-Ce(SO4)2 coexisted system

被引:25
作者
Chai, YH [1 ]
Ding, HC [1 ]
Zhang, ZH [1 ]
Xian, YZ [1 ]
Pan, ZS [1 ]
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
chemical oxygen demand (COD); photocatalytic oxidation; TiO2; Ce(IV); synergistic reaction; ultraviolet spectrophotometry;
D O I
10.1016/j.talanta.2005.04.074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new photocatalytic system, nano-TiO2-Ce(SO4)(2) coexisted system, which can be used to determine the low chemical oxygen demand (COD) is described. Nano-TiO2 powders is used as photocatalyst in this system. The measuring method is based on direct determination of the concentration change of Ce(IV) resulting from photocatalytic oxidation of organic compounds. The mechanism of the photocatalytic oxidation for COD determination was discussed and the optimum experimental conditions were investigated. Under the Optimum conditions, a good calibration graph for COD values between 1.0 and 12 mg l(-1) was obtained and the LOD value was achieved as low as 0.4 mg l(-1). When determining the real samples, the results were in good agreement with those from the conventional methods. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:610 / 615
页数:6
相关论文
共 34 条
[1]   Alternative method for determination of the chemical oxygen demand for colloidal polymeric wastewater [J].
Abuzaid, NS ;
AlMalack, MH ;
ElMubarak, AH .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1997, 59 (04) :626-630
[2]   Biodegradability enhancement of textile dyes and textile wastewater by VUV photolysis [J].
Al-Momani, F ;
Touraud, E ;
Degorce-Dumas, JR ;
Roussy, J ;
Thomas, O .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2002, 153 (1-3) :191-197
[3]  
APPLETON JMH, 1986, ANAL CHIM ACTA, V179, P269, DOI 10.1016/S0003-2670(00)84471-2
[4]   CHEMICAL OXYGEN-DEMAND DETERMINATION IN WELL AND RIVER WATERS BY FLOW-INJECTION ANALYSIS USING A MICROWAVE-OVEN DURING THE OXIDATION STEP [J].
BALCONI, ML ;
BORGARELLO, M ;
FERRAROLI, R ;
REALINI, F .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :295-299
[5]  
Bilanovic D, 1997, WATER SA, V23, P301
[6]   Rapid determination of chemical oxygen demand (COD) using focused microwave digestion followed by a titrimetric method [J].
Chen, SC ;
Tzeng, JH ;
Tien, Y ;
Wu, LF .
ANALYTICAL SCIENCES, 2001, 17 (04) :551-553
[7]  
FOX MA, 1992, CHEMTECH, V22, P680
[8]   MONITORING OF ENVIRONMENTAL WATER USING CONTINUOUS-FLOW [J].
GOTO, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1983, 2 (04) :92-94
[9]  
Greenberg A., 1992, Standard methods for the examination of water and wastewater
[10]   IONIC SPECIES IN CERIC PERCHLORATE SOLUTIONS [J].
HARDWICK, TJ ;
ROBERTSON, E .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1951, 29 (10) :818-827