Experimental investigation on model predictive control of radiant floor cooling combined with underfloor ventilation system

被引:35
|
作者
Zhang, Dongliang [1 ]
Cai, Ning [1 ]
Cui, Xiaobo [1 ]
Xia, Xueying [2 ]
Shi, Jianzhong [1 ]
Huang, Xiaoqing [1 ]
机构
[1] Nanjing Inst Technol, Sch Energy & Power Engn, Nanjing 211167, Jiangsu, Peoples R China
[2] Nanjing Normal Univ, Sch Energy & Mech Engn, Nanjing 210042, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Radiant floor cooling; Underfloor ventilation; Model predictive control; Proportion-integral-derivative control; Control performance; HEAT-TRANSFER COEFFICIENTS; PERFORMANCE; MANAGEMENT;
D O I
10.1016/j.energy.2019.03.102
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy saving potential of radiant floor cooling combined with underfloor ventilation (RFCUV) system has been restricted by its control problems. Existing conventional control methods of radiant cooling system have several disadvantages, such as control lag, poor control performance, and low economy, etc. The objectives of this study were to: (i) build a dynamic simplified model and validate its precision experimentally; (ii) implement advanced model predictive control (MPC) on RFCUV system; and (iii) demonstrate MPC control performance by comparing with existing conventional proportional-integral-derivative (PID) experimentally. Experimental results indicated that under experimental step setpoint variations, the adjusting time of indoor air temperature or operative temperature was only 12 min with MPC controller, and was 30 min with PID controller; it took only 1 min to reach recommended thermal comfort range with MPC controller, and 17 min with PID controller. During 9:00 to 17:00 in typical design day of Nanjing city, compared with PID controller, MPC controller yielded 17.5% energy saving when maintaining equal or better indoor comfort. Thus, compared with PID, MPC demonstrated the advantages of rapid responses, good stability and excellent energy saving effect in RFCUV system. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 50 条
  • [1] Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System
    Xia, Xue-ying
    Zhang, Xu
    LOW-CARBON CITY AND NEW-TYPE URBANIZATION, 2015, : 307 - 315
  • [2] An Experimental Study on Operating Characteristic of Radiant Floor Cooling Integrated with Underfloor Ventilation System
    Cai, Ning
    Zhang, Dongliang
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1207 - 1212
  • [3] Experimental Study on Performance Comparison Between Heavy and Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation Air Conditioning System
    Zhang, Dongliang
    Cai, Ning
    Rui, Yingxiang
    Tang, Hu
    Liu, Minghui
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 475 - 483
  • [4] Experimental study on control performance comparison between model predictive control and proportion-integral-derivative control for radiant ceiling cooling integrated with underfloor ventilation system
    Zhang, Dongliang
    Huang, Xiaoqing
    Gao, Dongyan
    Cui, Xiaobo
    Cai, Ning
    APPLIED THERMAL ENGINEERING, 2018, 143 : 130 - 136
  • [5] A dynamic simplified model of radiant ceiling cooling integrated with underfloor ventilation system
    Zhang, Dongliang
    Xia, Xueying
    Cai, Ning
    APPLIED THERMAL ENGINEERING, 2016, 106 : 415 - 422
  • [6] Developing a collaborative control strategy of a combined radiant floor cooling and ventilation system: A PMV-based model
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Miao, Jikui
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [7] Analysis of feasibility of floor radiant cooling system combined with displacement ventilation
    Li, DY
    Ren, YL
    Wang, ZJ
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 634 - 637
  • [8] Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation
    Jiying Liu
    Daniel Alejandro Dalgo
    Shengwei Zhu
    Hui Li
    Linhua Zhang
    Jelena Srebric
    Building Simulation, 2019, 12 : 905 - 919
  • [9] Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation
    Liu, Jiying
    Dalgo, Daniel Alejandro
    Zhu, Shengwei
    Li, Hui
    Zhang, Linhua
    Srebric, Jelena
    BUILDING SIMULATION, 2019, 12 (05) : 905 - 919
  • [10] A comparative experimental investigation on radiant floor heating system and stratum ventilation
    Li, Han
    Xi, Chang
    Kong, Xiangfei
    Lin, Zhang
    Wang, Lu
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52