Left Ventricular Functional Analysis With 16-and 64-Row Multidetector Computed Tomography: Comparison With Gated Single-Photon Emission Computed Tomography

被引:3
作者
Agarwal, Prachi P. [1 ]
Patel, Smita [1 ]
Corbett, James [1 ]
Jung, Jung Im [2 ]
Barber, Karen [1 ]
Schipper, Matthew [1 ]
Kazerooni, Ella A. [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Catholic Univ Korea, St Marys Hosp, Coll Med, Dept Radiol, Seoul, South Korea
关键词
multidetector CT; SPECT; left ventricular function; CONGESTIVE-HEART-FAILURE; MULTISLICE SPIRAL CT; MAGNETIC-RESONANCE; EJECTION FRACTION; WALL-MOTION; ROW CT; RECONSTRUCTION ALGORITHM; MYOCARDIAL-INFARCTION; CARDIAC-FUNCTION; SPECT;
D O I
10.1097/RCT.0b013e3181624ad0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the left ventricular (LV) ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) from electrocardiogram-gated computed tomography (CT) to gated single-photon emission computed tomography (SPECT). Methods: Fifty-seven patients underwent electrocardiogram-gated multidetector CT and SPECT examinations within a 3-month period, without interim cardiac events. The LV EF, EDV, and ESV were compared. Results: There was an excellent correlation between LV EF obtained from CT (60.25% +/- 12.93%) and SPECT (61.90% +/- 14.93%) (r = 0.81), with no significant difference (P = 0.17). Computed tomography-derived EDV and ESV correlated well with SPECT (r = 0.88 and 0.94, respectively). The EDV from SPECT (132.21 +/- 67.10 mL) was significantly lower than that from CT (147.53 +/- 55.03 mL; P = 0.0007); there was a trend for ESV from SPECT (58.39 +/- 61.20 mL) to be lower than that from CT (63.79 +/- 53.58 mL; P = 0.055). The EF, EDV, and ESV correlation of SPECT with the 64-row multidetector CT was better (r = 0.87, 0.89, and 0.96, respectively) than that with the 16-row CT (r = 0.36, 0.66, and 0.49, respectively). Conclusions: There is a good correlation between LV EF, EDV, and ESV from gated SPECT and CT (particularly the 64-row CT). The LV volumes are lower on SPECT than on CT.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 37 条
  • [1] Antonini-Canterin F, 2000, Ital Heart J Suppl, V1, P1261
  • [2] Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values
    Bavelaar-Croon, CDL
    Kayser, HWM
    van der Wall, EE
    de Roos, A
    Dibbets-Schneider, P
    Pauwels, EKJ
    Germano, G
    Atsma, DE
    [J]. RADIOLOGY, 2000, 217 (02) : 572 - 575
  • [3] Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy
    Bax, JJ
    Lamb, H
    Dibbets, P
    Pelikan, H
    Boersma, E
    Viergever, EP
    Germano, G
    Vliegen, HW
    de Roos, A
    Pauwels, EKJ
    Van der Wall, EE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (12) : 1299 - 1305
  • [4] Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT
    Boehm, T
    Alkadhi, H
    Roffi, M
    Willmann, JK
    Desbiolles, LM
    Marincek, B
    Wildermuth, S
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 529 - 537
  • [5] EARLS J, 2007, 9 ANN INT S MULT ROW
  • [6] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [7] Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods
    Faber, TL
    Vansant, JP
    Pettigrew, RI
    Galt, JR
    Blais, M
    Chatzimavroudis, G
    Cooke, CD
    Folks, RD
    Waldrop, SM
    Gurtler-Krawczynska, E
    Wittry, MD
    Garcia, EV
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) : 645 - 651
  • [8] GERBER TC, AM J CARDIOL
  • [9] TIME-COURSE OF IMPROVEMENT IN LEFT-VENTRICULAR FUNCTION, MASS AND GEOMETRY IN PATIENTS WITH CONGESTIVE-HEART-FAILURE TREATED WITH BETA-ADRENERGIC-BLOCKADE
    HALL, SA
    CIGARROA, CG
    MARCOUX, L
    RISSER, RC
    GRAYBURN, PA
    EICHHORN, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (05) : 1154 - 1161
  • [10] VARIABLES PREDICTIVE OF SURVIVAL IN PATIENTS WITH CORONARY-DISEASE - SELECTION BY UNIVARIATE AND MULTIVARIATE ANALYSES FROM THE CLINICAL, ELECTROCARDIOGRAPHIC, EXERCISE, ARTERIOGRAPHIC, AND QUANTITATIVE ANGIOGRAPHIC EVALUATIONS
    HAMMERMEISTER, KE
    DEROUEN, TA
    DODGE, HT
    [J]. CIRCULATION, 1979, 59 (03) : 421 - 430