Orthogonal-rotating tetrahedral scanning for cone-beam CT

被引:0
作者
Ye, Ivan B. [1 ]
Wang, Ge [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII | 2012年 / 8506卷
关键词
X-ray CT; cone-beam CT; CT scanning; tetrahedron; polyhedron; region of reconstruction; FILTERED BACKPROJECTION ALGORITHM; POSITRON EMISSION TOMOGRAPH; IMAGE-RECONSTRUCTION; ELECTRON-EMISSION;
D O I
10.1117/12.929179
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this article, a cone-beam CT scanning mode is designed assuming four x-ray sources and a spherical sample. The x-ray sources are mounted at the vertices of a regular tetrahedron. On the circumsphere of the tetrahedron, four detection panels are mounted opposite to each vertex. To avoid x-ray interference, the largest half angle of each x-ray cone beam is 27 degrees 22', while the radius of the largest ball fully covered by all the cone beams is 0.460, when the radius of the circumsphere is 1. Several scanning schemes are proposed which consist of two rotations about orthogonal axes, such that each quarter turn provides sufficient data for theoretically exact and stable reconstruction. This design can be used in biomedical or industrial settings, such as when a sequence of reconstructions of an object is desired. Similar scanning schemes based on other regular or irregular polyhedra and various rotation speeds are also discussed.
引用
收藏
页数:11
相关论文
共 31 条
[1]   SPHERICAL POSITRON EMISSION TOMOGRAPH (S-PET) I - PERFORMANCE ANALYSIS [J].
CHO, ZH ;
HONG, KS ;
HILAL, SK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (02) :422-438
[2]  
Danielsson P.E., 1997, P 1997 INT M FULLY 3, P141
[3]  
Ficke DC, 1996, J NUCL MED, V37, P1219
[4]   A triboelectric x-ray source [J].
Hird, J. R. ;
Camara, C. G. ;
Putterman, S. J. .
APPLIED PHYSICS LETTERS, 2011, 98 (13)
[5]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[6]   THIN-SECTION 3-DIMENSIONAL SPIRAL CT - IS ISOTROPIC IMAGING POSSIBLE [J].
KALENDER, WA .
RADIOLOGY, 1995, 197 (03) :578-580
[7]   Electron emission from silicon tips coated with sol-gel (Ba0.67Sr0.33)TiO3 ferroelectric thin film [J].
Kang, WP ;
Wisitsora-at, A ;
Davidson, JL ;
Tan, OK ;
Zhu, WG ;
Li, Q ;
Xu, JF .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (03) :1073-1076
[8]   An improved exact filtered backprojection algorithm for spiral computed tomography [J].
Katsevich, A .
ADVANCES IN APPLIED MATHEMATICS, 2004, 32 (04) :681-697
[9]   Theoretically exact filtered backprojection-type inversion algorithm for spiral CT [J].
Katsevich, A .
SIAM JOURNAL ON APPLIED MATHEMATICS, 2002, 62 (06) :2012-2026
[10]  
KATSEVICH A., 2003, International journal of mathematics and mathematical sciences, V2003, P1305, DOI DOI 10.1155/S0161171203209315