Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-A comparison with intravascular ultrasound

被引:61
|
作者
Fujino, Yusuke [1 ,2 ]
Bezerra, Hiram G. [1 ]
Attizzani, Guilherme F. [1 ]
Wang, Wei [1 ]
Yamamoto, Hirosada [1 ]
Chamie, Daniel [1 ]
Kanaya, Tomoaki [1 ]
Mehanna, Emile [1 ]
Tahara, Satoko [2 ]
Nakamura, Sunao [2 ]
Costa, Marco A. [1 ]
机构
[1] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington Heart & Vasc Inst, Cleveland, OH 44106 USA
[2] New Tokyo Hosp, Dept Cardiol, Chiba, Japan
关键词
optical coherence tomography; intravascular ultrasound; left main coronary artery disease; percutaneous coronary intervention; GUIDE DECISION-MAKING; ELUTING STENTS; INTERVENTION; GUIDANCE; IMPLANTATION; METAANALYSIS; FEASIBILITY; NEPHROPATHY; ANGIOGRAPHY; VALIDATION;
D O I
10.1002/ccd.24843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To investigate safety and feasibility of imaging unprotected left main (ULM) using frequency-domain optical coherence tomography (FD-OCT) compared with intravascular ultrasound (IVUS). Background: IVUS has been used to assess and guide percutaneous coronary intervention (PCI) of ULM disease. FD-OCT offers 10-fold higher axial resolution than IVUS and its high-speed image acquisition obviates the need for proximal balloon occlusion. Methods: We prospectively enrolled 35 consecutive patients with ULM disease. FD-OCT and IVUS assessments were attempted pre- and post-PCI and compared in regards to safety, ability to image the region of interest (ROI), number of pullbacks, volume of contrast and ability to detect malapposition, dissection, and thrombus. Results: Patients were followed for 1 year when FD-OCT imaging was repeated. FD-OCT required more repeated pullbacks to image the ROI compared to IVUS. Mean lumen and stent areas were similar between FD-OCT and IVUS (11.24 +/- 2.66 vs. 10.85 +/- 2.47 mm(2), P=0.13 and 10.44 +/- 2.33 vs. 10.49 +/- 2.32 mm(2), P=0.82, respectively), whereas imaged stent length was shorter with FD-OCT. Malapposition areas and volumes were larger and more edge dissections were detected by FD-OCT. There were no clinical adverse events and no complications associated with FD-OCT at baseline and 1-year follow-up. All dissections were healed, whereas stent malapposition was still detected at follow-up. Conclusions: FD-OCT assessment of ULM is feasible and safe. Direct comparisons with IVUS reveal that FD-OCT achieved imaging completeness less often, whereas it was more sensitive in detecting malapposition and edge dissections, and similar to IVUS in the assessment of lumen and stent dimensions. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:E173 / E183
页数:11
相关论文
共 50 条
  • [1] SAFETY AND FEASIBILITY OF FREQUENCY-DOMAIN OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT OF LEFT MAIN CORONARY ARTERY - A COMPARISON WITH INTRAVASCULAR ULTRASOUND
    Fujino, Yusuke
    Costa, Marco A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1444 - E1444
  • [2] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Aiko Shimokado
    Takashi Kubo
    Yoshiki Matsuo
    Yasushi Ino
    Yasutsugu Shiono
    Kunihiro Shimamura
    Yosuke Katayama
    Akira Taruya
    Tsuyoshi Nishiguchi
    Manabu Kashiwagi
    Hironori Kitabata
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1785 - 1790
  • [3] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Shimokado, Aiko
    Kubo, Takashi
    Matsu, Yoshiki
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Kashiwagi, Manabu
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10): : 1785 - 1790
  • [4] Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery
    Dimitris Karnabatidis
    Konstantinos Katsanos
    Ioannis Paraskevopoulos
    Athanasios Diamantopoulos
    Stavros Spiliopoulos
    Dimitris Siablis
    CardioVascular and Interventional Radiology, 2011, 34 : 1172 - 1181
  • [5] Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery
    Karnabatidis, Dimitris
    Katsanos, Konstantinos
    Paraskevopoulos, Ioannis
    Diamantopoulos, Athanasios
    Spiliopoulos, Stavros
    Siablis, Dimitris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (06) : 1172 - 1181
  • [6] Optical coherence tomography in unprotected left main coronary artery stenting
    Parodi, Guido
    Maehara, Akiko
    Giuliani, Gabriele
    Kubo, Takashi
    Mintz, Gary S.
    Migliorini, Angela
    Valenti, Renato
    Carrabba, Nazario
    Antoniucci, David
    EUROINTERVENTION, 2010, 6 (01) : 94 - 99
  • [7] OPTICAL COHERENCE TOMOGRAPHY IN UNPROTECTED LEFT MAIN CORONARY ARTERY STENTING
    Parodi, Guido
    Maehara, Akiko
    Giuliani, Gabriele
    Kubo, Takashi
    Mintz, Gary
    Vergara, Ruben
    Migliorini, Angela
    Valenti, Renato
    Carrabba, Nazario
    Antoniucci, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [8] Frequency-Domain Optical Coherence Tomography Assessment of Unfavorable Kissing-Balloon Result in Unprotected Left Main Intervention
    Fujino, Yusuke
    Attizzani, Guilherme F.
    Tahara, Satoko
    Takagi, Kensuke
    Bezerra, Hiram G.
    Nakamura, Sunao
    Costa, Marco A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (12) : 1324 - 1325
  • [10] Serial Assessment of Vessel Interactions After Drug-Eluting Stent Implantation in Unprotected Distal Left Main Coronary Artery Disease Using Frequency-Domain Optical Coherence Tomography
    Fujino, Yusuke
    Attizzani, Guilherme F.
    Bezerra, Hiram G.
    Wang, Wei
    Tahara, Satoko
    Yamamoto, Hirosada
    Chamie, Daniel
    Kanaya, Tomoaki
    Mehanna, Emile
    Takagi, Kensuke
    Nakamura, Sunao
    Costa, Marco A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (10) : 1035 - 1045