Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: A prospective case control study

被引:75
作者
Haldar, Shouvik [1 ,2 ]
Jarman, Julian W. E. [1 ,2 ]
Panikker, Sandeep [1 ,2 ]
Jones, David G. [1 ,2 ]
Salukhe, Tushar [1 ,2 ]
Gupta, Dhiraj [3 ]
Wynn, Gareth [3 ]
Hussain, Wajid [1 ,2 ]
Markides, Vias [1 ,2 ]
Wong, Tom [1 ,2 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, London SW3 6NP, England
[2] Univ London Imperial Coll Sci Technol & Med, Inst Cardiovasc Med & Sci, London SW7 2AZ, England
[3] Liverpool Heart & Chest Hosp NHS Fdn Trust, Inst Cardiovasc Med & Sci, Liverpool, Merseyside, England
关键词
Atrial fibrillation; Catheter ablation; Contact force; Pulmonary vein isolation; PAROXYSMAL ATRIAL-FIBRILLATION; CATHETER ABLATION; RECURRENCE; CONDUCTION; INITIATION; LESSONS; RHYTHM;
D O I
10.1016/j.ijcard.2012.11.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Contact force (CF) sensing technology allows real time CF measurement during catheter ablation. We hypothesised that the use of CF technology during pulmonary vein isolation (PVI) for atrial fibrillation (AF) would translate into lower acute pulmonary vein (PV) reconnection rates. Methods and results: Symptomatic AF patients were treated in two groups, 'unblinded' and 'blinded', each containing 20 patients undergoing first time PVI. An irrigated radiofrequency CF sensing catheter was used in both groups. In the 'unblinded' group, the operator could view the CF value during mapping and ablation in real time. In the 'blinded group', the operator was 'blinded' to this information during the procedure, although the data were recorded. All 80 PVs were successfully isolated with exit and entrance block re-tested after 1 h with adenosine. There was a significant association between blinding and the rate of acute PV reconnection. 17/80 (21%) of the PVs in the blinded subjects had a reconnection while 3/80 (4%) of the PVs in the unblinded subjects had a reconnection (p=0.001). Blinding the operator resulted in lower mean CF overall (11.6 g (10.5, 12.9 g) vs. 14.4 g (13.3, 15.7 g); p=0.002). Sites where applied CF was significantly lower than others were usually the sites where reconnection occurred: these were the ridge between the left upper PV and appendage, and the right carina. Conclusions: CF data identified key areas where CF was poor. These were the areas of acute reconnection. Availability of real time CF information during PVI was associated with a significantly lower acute pulmonary vein reconnection rate. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1160 / 1166
页数:7
相关论文
共 26 条
[1]   Long-term results and the predictors of outcome of catheter ablation of atrial fibrillation using steerable sheath catheter navigation after single procedure in 674 patients [J].
Arya, Arash ;
Hindricks, Gerhard ;
Sommer, Philipp ;
Huo, Yan ;
Bollmann, Andreas ;
Gaspar, Thomas ;
Bode, Kerstin ;
Husser, Daniela ;
Kottkamp, Hans ;
Piorkowski, Christopher .
EUROPACE, 2010, 12 (02) :173-180
[2]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[3]   Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation [J].
Callans, DJ ;
Gerstenfeld, EP ;
Dixit, S ;
Zado, E ;
Vanderhoff, M ;
Ren, JF ;
Marchlinski, FE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) :1050-1055
[4]   Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation [J].
Cappato, R ;
Negroni, S ;
Pecora, D ;
Bentivegna, S ;
Lupo, PP ;
Carolei, A ;
Esposito, C ;
Furlanello, F ;
De Ambroggi, L .
CIRCULATION, 2003, 108 (13) :1599-1604
[5]   Incidence and time course of early recovery of pulmonary vein conduction after catheter ablation of atrial fibrillation [J].
Cheema, Aamir ;
Dong, Jun ;
Dalal, Darshan ;
Marine, Joseph E. ;
Henrikson, Charles A. ;
Spragg, David ;
Cheng, Alan ;
Nazarian, Saman ;
Bilchick, Kenneth ;
Sinha, Sunil ;
Scherr, Daniel ;
Almasry, Ibrahim ;
Halperin, Henry ;
Berger, Ronald ;
Calkins, Hugh .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (04) :387-391
[6]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[7]   Improved Electrogram Attenuation during Ablation of Paroxysmal Atrial Fibrillation with the Hansen Robotic System [J].
Duncan, Edward R. ;
Finlay, Malcolm ;
Page, Stephen P. ;
Hunter, Ross ;
Goromonzi, Farai ;
Richmond, Laura ;
Baker, Victoria ;
Ginks, Matthew ;
Ezzat, Vivienne ;
Dhinoja, Mehul ;
Earley, Mark J. ;
Sporton, Simon ;
Schilling, Richard J. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (06) :730-738
[8]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[9]   Contact Sensing Provides a Highly Accurate Means to Titrate Radiofrequency Ablation Lesion Depth [J].
Holmes, Douglas ;
Fish, Jeffrey M. ;
Byrd, Israel A. ;
Dando, Jeremy D. ;
Fowler, Steven J. ;
Cao, Hong ;
Jensen, James A. ;
Puryear, Harry A. ;
Chinitz, Larry A. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (06) :684-690
[10]   Dissociated pulmonary vein rhythm may predict the acute pulmonary vein reconnection post-isolation in patients with paroxysmal atrial fibrillation [J].
Jiang, Chen-yang ;
Fu, Jian-wei ;
Matsuo, Seiichiro ;
Nault, Isabelle ;
He, Hong ;
Jiang, Ru-hong ;
Liu, Qiang ;
Fan, You-qi ;
Sheng, Xia ;
Zhang, Zhu-wen ;
Fu, Guo-sheng .
EUROPACE, 2011, 13 (07) :949-954