Image-guided and -monitored renal artery stenting using only MRI

被引:34
作者
Elgort, DR
Hillenbrand, CM
Zhang, SX
Wong, EY
Rafie, S
Lewin, JS
Duerk, JL
机构
[1] Univ Hosp Cleveland, Dept Radiol, MRI, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
关键词
interventional MRI; active catheter tracking; renal artery disease; real-time imaging; fibrotic stenosis;
D O I
10.1002/jmri.20554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the ability of a unique interventional MR system to be used safely and effectively as the only imaging modality for all phases of MR-guided Stent-supported angioplasty. Materials and Methods: An experimental disease model of renal stenosis was created in six pigs. An interventional MR system, which employed previously reported tools for real-time catheter tracking with automated scan-plane positioning, adaptive image parameters, and radial true-FISP imaging with steady-state precession (True-FISP) imaging coupled with a high-speed reconstruction technique, was then used to guide all phases of the intervention, including: guidewire and catheter insertion. stent deployment, and confirmation of therapeutic success. Pre- and postprocedural X-ray imaging was used as a gold standard to validate the experimental results. Results: All of the stent-supported angioplasty interventions were a technical success and were performed without complications. The average postoperative residual stenosis was 14.9%. The image guidance enabled the stents to be deployed with an accuracy of 0.98 +/- 0.69 mm. Additionally, using this interventional MRI system to guide renal artery stenting significantly reduces the procedure time, as compared to using X-ray fluoroscopy. Conclusion: This study has clearly demonstrated the first successful treatment of renal artery stenting in an experimental animal model solely under MRI guidance and monitoring.
引用
收藏
页码:619 / 627
页数:9
相关论文
共 42 条
[1]  
Aoki S, 1999, Radiat Med, V17, P251
[2]   High resolution intravascular MRI and MRS by using a catheter receiver coil [J].
Atalar, E ;
Bottomley, PA ;
Ocali, O ;
Correia, LCL ;
Kelemen, MD ;
Lima, JAC ;
Zerhouni, EA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :596-605
[3]   Endovascular interventional magnetic resonance imaging [J].
Bartels, LW ;
Bakker, CJG .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14) :R37-R64
[4]   Can MR measurement of renal artery flow and renal volume predict the outcome of percutaneous transluminal renal angioplasty? [J].
Binkert, CA ;
Debatin, JF ;
Schneider, E ;
Hodler, J ;
Ruehm, SG ;
Schmidt, M ;
Hoffmann, U .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 24 (04) :233-239
[5]   RENAL TOLERANCE OF GADOLINIUM-DOTA AND GADOLINIUM-DTPA IN RATS [J].
BRILLET, G ;
DUBOIS, M ;
BEAUFILS, H ;
BOURBOUZE, R ;
DERAY, G .
INVESTIGATIVE RADIOLOGY, 1994, 29 (03) :352-354
[6]   Simultaneous real-time visualization of the catheter tip and vascular anatomy for MR-guided PTA of iliac arteries in an animal model [J].
Buecker, A ;
Adam, GB ;
Neuerburg, JM ;
Kinzel, S ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Guenther, RW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :201-208
[7]   Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition [J].
Correia, LCL ;
Atalar, E ;
Kelemen, MD ;
Ocali, O ;
Hutchins, GM ;
Fleg, JL ;
Gerstenblith, G ;
Zerhouni, EA ;
Lima, JAC .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) :3626-3632
[8]   A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories [J].
Dale, B ;
Wendt, M ;
Duerk, JL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (03) :207-217
[9]  
DORROS G, 2000, CIRCULATION, V102, P1671
[10]   A brief review of hardware for catheter tracking in magnetic resonance imaging [J].
Duerk, JL ;
Wong, EY ;
Lewin, JS .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03) :199-208