Punching shear of RC flat slabs - Review of analytical models for new and strengthening of existing slabs

被引:41
作者
Koppitz, Robert [1 ]
Kenel, Albin [2 ]
Keller, Thomas [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Composite Construct Lab, Stn 16, CH-1015 Lausanne, Switzerland
[2] HSR Rapperswil Univ Appl Sci, Construct & Environm Inst, CH-8640 Rapperswil, Switzerland
关键词
Reinforced concrete; Flat slab; Punching shear; Strengthening; Pre-damage; Anchorage; Pretensioning; REINFORCED-CONCRETE SLABS; EQUIVALENT BEAM MODEL; COLUMN CONNECTIONS; BUILDINGS; OPENINGS; FAILURE; EDGE;
D O I
10.1016/j.engstruct.2013.02.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The conversion of existing buildings, development of standards, material deterioration and detailing deficiencies have led to a need for strengthening an increasing number of concrete flat slabs against brittle punching shear failure. However, existing analytical and design models do not yet take into account the specific aspects of strengthening slabs against punching shear. More than 40 models exist for predicting the punching shear strength of new slabs. A three-level classification is proposed to provide a consistent overview of the wide range of approaches adopted for resistance calculation. Based on this classification, models are evaluated with regard to their applicability for problems specific to the strengthening of existing slabs, such as pre-damage of existing slabs, insufficient anchorage lengths of tensile reinforcement outside the punching zone, new openings in slabs within the punching zone, and the prestressing of post-installed shear reinforcement. The efficiency of current strengthening solutions is evaluated, suggesting local prestressing as a promising method. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 77 条
[1]  
ALEXANDER SDB, 1992, ACI STRUCT J, V89, P325
[2]  
Andersson JL, 1963, T ROYAL I TECHNOLOGY, V212
[3]  
Andra H-P, 1982, THESIS U STUTTGART G
[4]  
[Anonymous], 1938, DAFSTB HEFT
[5]  
[Anonymous], P ACI J
[6]  
[Anonymous], 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary
[7]  
[Anonymous], 1960, T ROYAL I TECHNOLOGY
[8]  
Aschwanden. RINO Durchstanzverstarkung, 2012, RINO DURCHST PROD LI
[9]  
BAZANT ZP, 1987, ACI STRUCT J, V84, P44
[10]  
Beutel RRK, 2003, THESIS RWTH AACHEN U