Instrumental isotope fractionation in multiple-collector icp-ms

被引:39
作者
Albarede, Francis [1 ]
Albalat, Emmanuelle
Telouk, Philippe
机构
[1] Ecole Normale Super Lyon, F-69007 Lyon, France
关键词
PLASMA-MASS-SPECTROMETRY; ATOMIC-WEIGHT; RATIO MEASUREMENTS; ABUNDANCE RATIOS; SPACE-CHARGE; PRECISION; DISCRIMINATION; INTERFERENCES; ACCURACY; SAMPLES;
D O I
10.1039/c5ja00188a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work addresses the issue of how isotope mass biases in modern Multiple-Collector Inductively Coupled Plasma Mass Spectrometers (MC-ICP-MS) changes with increasing efficiency of ion transfer through the instrument, which is known as transmission (tau). For any element, when all the ions introduced into the source are accounted for at the collector, the instrumental mass bias must vanish. With the latest cone designs, such as Thermo Finnigan jet cones, transmissions in excess of 2 percent are now obtained for heavy elements and coincide with smaller values of instrumental isotope fractionation factors. Transmission of ions across the entire mass range has been measured on a Thermo Neptune Plus equipped with standard and jet cones. It was found that transmission tau of elements above mass 40 increases linearly with the atomic weight. Comparing this relationship with the well-established linear dependence of ion energy with atomic mass indicates that high transmission is intimately related to the thermodynamic reversibility of the gas flow in the interface. Instrumental isotope fractionation obeys an exponential law with beta as a coefficient. Instrumental isotopic fractionation is due to the transverse spread of the beam inherited from Ar thermal movements at the high temperatures of the plasma. It was found that, for tau > 0.002, the exponential law coefficient beta approximate to -0.24 +/- 0.02 ln tau in contrast to beta approximate to 2 at lower transmission. The exponential mass fractionation coefficient can be approximated by the following law: beta = beta(0) (1 - tau(gamma)).
引用
收藏
页码:1736 / 1742
页数:7
相关论文
共 39 条
[1]   Precise and accurate isotopic measurements using multiple-collector ICPMS [J].
Albarède, F ;
Telouk, P ;
Blichert-Toft, J ;
Boyet, M ;
Agranier, A ;
Nelson, B .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (12) :2725-2744
[2]   Separation of Hf and Lu for high-precision isotope analysis of rock samples by magnetic sector multiple collector ICP-MS [J].
BlichertToft, J ;
Chauvel, C ;
Albarede, F .
CONTRIBUTIONS TO MINERALOGY AND PETROLOGY, 1997, 127 (03) :248-260
[3]  
Brewer G. R., 1967, FOCUSING CHARGED PAR, P23
[4]   ABSOLUTE ISOTOPIC ABUNDANCE RATIOS AND ATOMIC WEIGHT OF MAGNESIUM [J].
CATANZAR.EJ ;
MURPHY, TJ ;
GARNER, EL ;
SHIELDS, WR .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1966, A 70 (06) :453-+
[5]   FUNDAMENTAL-STUDIES OF THE SAMPLING PROCESS IN AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER .2. ION KINETIC-ENERGY MEASUREMENTS [J].
CHAMBERS, DM ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :761-784
[6]   LITHIUM ISOTOPIC COMPOSITION OF SUBMARINE BASALTS - IMPLICATIONS FOR THE LITHIUM CYCLE IN THE OCEANS [J].
CHAN, LH ;
EDMOND, JM ;
THOMPSON, G ;
GILLIS, K .
EARTH AND PLANETARY SCIENCE LETTERS, 1992, 108 (1-3) :151-160
[7]   Absolute isotopic composition and atomic weight of dysprosium [J].
Chang, TL ;
Li, WJ ;
Zhao, MT ;
Wang, J ;
Qian, QY .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 207 (1-2) :13-17
[8]  
Cutler C. C., 1955, P IRE, V43, P307
[9]   GAS-DYNAMICS OF THE INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY INTERFACE [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :743-747
[10]   ABSOLUTE ISOTOPIC ABUNDANCE AND THE ATOMIC WEIGHT OF A REFERENCE SAMPLE OF THALLIUM [J].
DUNSTAN, LP ;
GRAMLICH, JW ;
BARNES, IL ;
PURDY, WC .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1980, 85 (01) :1-10