Magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples

被引:65
作者
Ranjbari, Elias [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
机构
[1] Univ Mazandaran, Dept Analyt Chem, Fac Chem, Babol Sar, Iran
关键词
Magnetic stirring-assisted; Dispersive liquid-liquid microextraction; High performance liquid chromatography; Phthalate ester; Drinking water; Environmental water; SOLID-PHASE EXTRACTION; GAS-CHROMATOGRAPHY; EMULSIFICATION-MICROEXTRACTION; MASS-SPECTROMETRY; ACID-ESTERS; HUMAN URINE; HPLC-UV; PRECONCENTRATION; PLASTICIZERS; CHEMICALS;
D O I
10.1016/j.talanta.2012.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast and efficient method for the preconcentration of phthalate esters (PEs) in water samples was developed using magnetic stirring-assisted dispersive liquid-liquid microextraction (MSA-DLLME) followed by high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV). This novel microextraction method is based on the fast injection of extracting solvent into the aqueous solution, which is being stirred by a magnetic stirrer, to form a cloudy binary component solvent (aqueous solution:extracting solvent) system. The extraction parameters such as type and volume of extracting solvent, pH of sample, salt addition, extraction time and stirring rate were optimized. Under the optimal conditions (extracting solvent: 200 mu L dodecane; pH of sample: 6.5; extraction time: 5 min; stirring rate: 1000 rpm), linearity was observed in the range of 2-1000 mu g L-1 for dimethyl phthalate (DMP) and 1-1000 mu g L-1 for diethyl phthalate (DEP), benzyl butyl phthalate (BBP) and di-n-butyl phthalate (DBP) with correlation determination values above 0.99 for them. The limits of detection and quantification were ranged from 0.13 to 0.38 mu g mL(-1) and 0.43 to 1.27 mu g mL(-1), respectively. The ranges of intra-day and inter-day precisions (n=5) at 100 mu g L-1 of PEs were 1.50-2.65% and 2.31-3.35%, respectively. Finally, the MSA-DLLME method was successfully applied for preconcentration of PEs in drinking and environmental water samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 37 条
  • [11] Determination of phthalates in water samples using polystyrene solid-phase extraction and liquid chromatography quantification
    Jara, S
    Lysebo, C
    Greibrokk, T
    Lundanes, E
    [J]. ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) : 165 - 171
  • [12] Determination of phthalate esters from food-contacted materials by on-line microdialysis and liquid chromatography
    Jen, Jen-Fon
    Liu, Tzu-Chi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (01) : 28 - 33
  • [13] A VARIETY OF ENVIRONMENTALLY PERSISTENT CHEMICALS, INCLUDING SOME PHTHALATE PLASTICIZERS, ARE WEAKLY ESTROGENIC
    JOBLING, S
    REYNOLDS, T
    WHITE, R
    PARKER, MG
    SUMPTER, JP
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1995, 103 (06) : 582 - 587
  • [14] Optimization of ultrasound-assisted emulsification microextraction with solidification of floating organic droplet followed by high performance liquid chromatography for the analysis of phthalate esters in cosmetic and environmental water samples
    Kamarei, Fahimeh
    Ebrahimzadeh, Homeira
    Yamini, Yadollah
    [J]. MICROCHEMICAL JOURNAL, 2011, 99 (01) : 26 - 33
  • [15] Determination of three phthalate metabolites in human urine using on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Kato, K
    Shoda, S
    Takahashi, M
    Doi, N
    Yoshimura, Y
    Nakazawa, H
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 407 - 411
  • [16] PHTHALATE-ESTERS AND OTHER INDUSTRIAL ORGANIC-CHEMICALS IN THE NORTH AND IRISH SEAS
    LAW, RJ
    FILEMAN, TW
    MATTHIESSEN, P
    [J]. WATER SCIENCE AND TECHNOLOGY, 1991, 24 (10) : 127 - 134
  • [17] Analysis of phthalates via HPLC-UV in environmental water samples after concentration by solid-phase extraction using ionic liquid mixed hemimicelles
    Li, Jidong
    Cai, Yaqi
    Shi, Yali
    Mou, Shifen
    Jiang, Guibin
    [J]. TALANTA, 2008, 74 (04) : 498 - 504
  • [18] Determination of phthalate acid esters plasticizers in plastic by ultrasonic solvent extraction combined with solid-phase microextraction using calix[4]arene fiber
    Li, XJ
    Zeng, ZR
    Chen, Y
    Xu, Y
    [J]. TALANTA, 2004, 63 (04) : 1013 - 1019
  • [19] Application of dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of three phthalate esters in water samples
    Liang, Pei
    Xu, Jing
    Li, Qian
    [J]. ANALYTICA CHIMICA ACTA, 2008, 609 (01) : 53 - 58
  • [20] Analysis of trace contamination of phthalate esters in ultrapure water using a modified solid-phase extraction procedure and automated thermal desorption-gas chromatography/mass spectrometry
    Liu, Hsu-Chuan
    Den, Walter
    Chan, Shu-Fei
    Kin, Kuan Tzu
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 286 - 294