Magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples

被引:65
|
作者
Ranjbari, Elias [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
机构
[1] Univ Mazandaran, Dept Analyt Chem, Fac Chem, Babol Sar, Iran
关键词
Magnetic stirring-assisted; Dispersive liquid-liquid microextraction; High performance liquid chromatography; Phthalate ester; Drinking water; Environmental water; SOLID-PHASE EXTRACTION; GAS-CHROMATOGRAPHY; EMULSIFICATION-MICROEXTRACTION; MASS-SPECTROMETRY; ACID-ESTERS; HUMAN URINE; HPLC-UV; PRECONCENTRATION; PLASTICIZERS; CHEMICALS;
D O I
10.1016/j.talanta.2012.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast and efficient method for the preconcentration of phthalate esters (PEs) in water samples was developed using magnetic stirring-assisted dispersive liquid-liquid microextraction (MSA-DLLME) followed by high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV). This novel microextraction method is based on the fast injection of extracting solvent into the aqueous solution, which is being stirred by a magnetic stirrer, to form a cloudy binary component solvent (aqueous solution:extracting solvent) system. The extraction parameters such as type and volume of extracting solvent, pH of sample, salt addition, extraction time and stirring rate were optimized. Under the optimal conditions (extracting solvent: 200 mu L dodecane; pH of sample: 6.5; extraction time: 5 min; stirring rate: 1000 rpm), linearity was observed in the range of 2-1000 mu g L-1 for dimethyl phthalate (DMP) and 1-1000 mu g L-1 for diethyl phthalate (DEP), benzyl butyl phthalate (BBP) and di-n-butyl phthalate (DBP) with correlation determination values above 0.99 for them. The limits of detection and quantification were ranged from 0.13 to 0.38 mu g mL(-1) and 0.43 to 1.27 mu g mL(-1), respectively. The ranges of intra-day and inter-day precisions (n=5) at 100 mu g L-1 of PEs were 1.50-2.65% and 2.31-3.35%, respectively. Finally, the MSA-DLLME method was successfully applied for preconcentration of PEs in drinking and environmental water samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 50 条
  • [1] Dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples
    Xue, Linke
    Zhang, Dongxia
    Wang, Tiane
    Wang, Xue-Mei
    Du, Xinzhen
    ANALYTICAL METHODS, 2014, 6 (04) : 1121 - 1127
  • [2] Determination of selective serotonin reuptake inhibitors in biological samples via magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography
    Golbabanezhadazizi, A.
    Ranjbari, E.
    Hadjmohammadi, M. R.
    Daneshinejad, H.
    RSC ADVANCES, 2016, 6 (56) : 50710 - 50720
  • [3] A new device for magnetic stirring-assisted dispersive liquid-liquid microextraction of UV filters in environmental water samples
    Zhang, Ping-Ping
    Shi, Zhi-Guo
    Yu, Qiong-Wei
    Feng, Yu-Qi
    TALANTA, 2011, 83 (05) : 1711 - 1715
  • [4] Application of dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of three phthalate esters in water samples
    Liang, Pei
    Xu, Jing
    Li, Qian
    ANALYTICA CHIMICA ACTA, 2008, 609 (01) : 53 - 58
  • [5] Determination of herbicides in environmental water samples by simultaneous in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation followed by GC-MS
    Suarez, Ruth
    Clavijo, Sabrina
    Gonzalez, Alba
    Cerda, Victor
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (05) : 1096 - 1103
  • [6] Determination of polybrominated biphenyls in environmental water samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography
    Wang, Xuemei
    Du, Tongtong
    Wang, Juan
    Kou, Haixia
    Du, Xinzhen
    MICROCHEMICAL JOURNAL, 2019, 148 : 85 - 91
  • [7] In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid-liquid microextraction
    Horstkotte, Burkhard
    Suarez, Ruth
    Solich, Petr
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2013, 788 : 52 - 60
  • [8] Determination of Atrazine and Simazine in Environmental Water Samples by Dispersive Liquid-Liquid Microextraction with High Performance Liquid Chromatography
    Zhou, Qingxiang
    Pang, Long
    Xie, Guohong
    Xiao, Junping
    Bai, Huahua
    ANALYTICAL SCIENCES, 2009, 25 (01) : 73 - 76
  • [9] Determination of Atrazine and Simazine in Environmental Water Samples by Dispersive Liquid-Liquid Microextraction with High Performance Liquid Chromatography
    School of Chemistry and Environmental Sciences, Henan Normal University, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow River and, Huaihe River Water Environment and Pollution Control, Ministry of Education, Xinxiang 453007, China
    不详
    不详
    Anal. Sci., 1 (73-76):
  • [10] Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography for the Determination of Nonylphenol in Environmental Water Samples
    Yang, Yingchun
    Mo, Li
    Wang, Jinmei
    Wang, Mingwei
    Zhou, Shiyu
    CONFERENCE ON ENVIRONMENTAL POLLUTION AND PUBLIC HEALTH, VOL 1-2, 2010, : 875 - 878