Virtual cystoscopy by intravesical instillation of dilute contrast medium: Preliminary experience

被引:12
作者
Kishore, TA
George, GK
Bhat, S
机构
[1] Govt Med Coll, Dept Urol, Kottayam, Kerala, India
[2] Gigos Scan Clin, Kottayam, Kerala, India
关键词
bladder; carcinoma; bladder neoplasms; cystoscopy; tomography; emission-computed;
D O I
10.1016/S0022-5347(05)00345-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We determined whether virtual cystoscopy based on helical data sets can yield urinary capabilities similar to those achieved by fiber-optic cystoscopy. Materials and Methods: A total of 11 patients with ultrasound detected bladder tumors underwent pelvic CT as a single volumetric scan after preliminary bladder distention with saline mixed with contrast medium using a 6Fr infant feeding tube. Cystoscopy was simulated based on a 3-dimensional helical CT data set in real time. Source raw CT data for virtual cystoscopy were reconstructed and navigation was done in real time using surface rendering navigation software. These images and findings were then compared with conventional cystoscopy findings. Results: An attenuation gradient of 350 HU between the vesical mucosa and urine was noted. Two of the 14 tumors (11 patients) were missed and each was 0.7 cm. All tumors greater than 0.9 cm were detected. Overall sensitivity was 85.7%. There were no false-positive findings. There was good correlation with tumor location and size. The ureteral orifices and their relationship to the tumor were also well appreciated. Subtle mucosal changes on conventional cystoscopy were not delineated by virtual cystoscopy. Conclusions: Our method of instilling dilute contrast medium in the bladder offers an excellent attenuation gradient. The overall sensitivity of tumor detection is better than that reported for intravenous contrast medium and pneumocystoscopy.
引用
收藏
页码:870 / 874
页数:5
相关论文
共 19 条
[1]   CT cystography and virtual cystoscopy in the assessment of new and recurrent bladder neoplasms [J].
Browne, RFJ ;
Murphy, SM ;
Grainger, R ;
Hamilton, S .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 53 (01) :147-153
[2]   Three-dimensional volume rendering of spiral CT data: Theory and method [J].
Calhoun, PS ;
Kuszyk, BS ;
Heath, DG ;
Carley, JC ;
Fishman, EK .
RADIOGRAPHICS, 1999, 19 (03) :745-764
[3]  
DACHMAN AH, 1996, AM J ROENTGENOL S, V166, P84
[4]   Virtual cystoscopy: Early clinical experience [J].
Fenlon, HM ;
Bell, TV ;
Ahari, HK ;
Hussain, S .
RADIOLOGY, 1997, 205 (01) :272-275
[5]  
FERETTI G, 1995, RADIOLOGY S, V197, P201
[6]  
Gualdi G F, 1999, Radiol Med, V97, P506
[7]   Intravenous urography-virtual cystoscopy is a better preliminary examination that air virtual cystoscopy [J].
Kawai, N ;
Mimura, T ;
Nagata, D ;
Tozawa, K ;
Kohri, K .
BJU INTERNATIONAL, 2004, 94 (06) :832-836
[8]   Virtual cystoscopy of the contrast material-filled bladder in patients with gross hematuria [J].
Kim, JK ;
Ahn, JH ;
Park, T ;
Ahn, HJ ;
Kim, CS ;
Cho, KS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (03) :763-768
[9]  
Lämmle M, 2002, AM J ROENTGENOL, V178
[10]   Virtual cystoscopy based on helical CT scan datasets:: perspectives and limitations [J].
Merkle, EM ;
Wunderlich, A ;
Aschoff, AJ ;
Rilinger, N ;
Görich, J ;
Bachor, R ;
Gottfried, HW ;
Sokiranski, R ;
Fleiter, TR ;
Brambs, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (843) :262-267