Tests and prediction model for time-dependent internal relative humidity of recycled aggregate concrete due to self-desiccation

被引:6
作者
Chen, Xuepeng [1 ,2 ]
Zhang, Huan [1 ,2 ]
Geng, Yue [1 ,2 ,3 ]
Wang, Yu-Yin [1 ,2 ]
机构
[1] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
[3] Guangdong Prov Key Lab Modern Civil Engn Technol, Guangzhou 510641, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Relative humidity; Recycled aggregate concrete; Self-desiccation; Internal curing effect; Hydration model; Relative humidity prediction model; HIGH-PERFORMANCE CONCRETE; SUPER ABSORBENT POLYMERS; HIGH-STRENGTH CONCRETE; EARLY-AGE CONCRETE; LIGHTWEIGHT AGGREGATE; CEMENT HYDRATION; MOISTURE; FINE; SHRINKAGE; COARSE;
D O I
10.1016/j.conbuildmat.2022.129024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concrete internal relative humidity (RH) is the direct evidence of internal curing effect, controlling concrete shrinkage deformation and also affecting the strength development, creep and cracking risk of concrete structures. However, no studies have been conducted on the internal RH development due to self-desiccation and its model for recycled aggregate concrete (RAC). Therefore, this study aims to quantify the coarse recycled aggregate and fine recycled aggregate (CRA and FRA) influence on the internal RH and establish a prediction model. RAC specimens were designed considering the replacement ratios of CRA and FRA of 0, 50 % and 100 %, and their internal RH was monitored for 185 days. Based on the Ba.zant hydration model for natural aggregate concrete (NAC), the model for RAC was theoretically proposed considering the influence of CRA and FRA on the initial water-to-cement ratio and the dynamic water release process. Results showed that (1) Both CRA and FRA have a significant internal curing effect, decreasing the RH loss by 61.4 % when both CRA and FRA are fully used; (2) The influence of CRA on the internal curing effect is more pronounced than that of FRA, and a coupling effect exists between the influences of CRA and FRA; (3) The proposed model can accurately predict the timedependent internal RH of RAC, with the maximum difference of 0.5 %.
引用
收藏
页数:12
相关论文
共 59 条
[21]   Structural Behaviour of Composite Members with Recycled Aggregate Concrete - an Overview [J].
Li, Wengui ;
Xiao, Jianzhuang ;
Shi, Caijun ;
Poon, Chi Sun .
ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (06) :919-938
[22]   Internal curing effect of saturated recycled fine aggregates in early-age mortar [J].
Li, Zhen ;
Liu, Jiaping ;
Xiao, Jianzhuang ;
Zhong, Peihua .
CEMENT & CONCRETE COMPOSITES, 2020, 108
[23]   Microstructure-based modelling of drying shrinkage and microcracking of cement paste at high relative humidity [J].
Liu, Lin ;
Wang, Xuecheng ;
Chen, Huisu ;
Wan, Chaojun .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 :410-425
[24]  
LNEC (National Laboratory of Civil Engineering), 2009, LNECE471
[25]   Internal curing with lightweight aggregate produced from biomass-derived waste [J].
Lura, Pietro ;
Wyrzykowski, Mateusz ;
Tang, Clarence ;
Lehmann, Eberhard .
CEMENT AND CONCRETE RESEARCH, 2014, 59 :24-33
[26]  
Meng L.Y., 2011, ADV MATER RES-KR, P725
[27]  
Ministry of Housing and Urban-Rural Development of the People's Republic of China, 2006, JGJ 52-2006
[28]  
Ministry of Housing and Urban-Rural Development of the People's Republic of China, 2011, TECHNICAL SPECIFICAT
[29]   Hydration and microstructure of ultra high performance concrete incorporating rice husk ash [J].
Nguyen Van Tuan ;
Ye, Guang ;
van Breugel, Klaas ;
Copuroglu, Oguzhan .
CEMENT AND CONCRETE RESEARCH, 2011, 41 (11) :1104-1111
[30]   Long-term moisture transport in high performance concrete [J].
Nilsson, L.-O. .
Materials and Structures/Materiaux et Constructions, 2002, 35 (254) :641-649