Use of combined PET/CT images for radiotherapy planning: initial experiences in lung cancer

被引:10
作者
Jarritt, PH
Hounsell, AR
Carson, KJ
Visvikis, D
Cosgrove, VP
Clarke, JC
Stewart, DP
Fleming, VAL
Eakin, RL
Zatari, A
机构
[1] No Ireland Reg Med Phys Agcy, Belfast BT12 6BA, Antrim, North Ireland
[2] Belvoir Pk Hosp, Belfast BT8 8JR, Antrim, North Ireland
[3] No Ireland Reg Med Phys Agcy, Belfast BT8 8JR, Antrim, North Ireland
[4] INSERM, U650, LaTIM, Brest, France
[5] Royal Grp Hosp, Dept Radiol, Belfast BT12 6BA, Antrim, North Ireland
关键词
D O I
10.1259/bjr/14526714
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential role of positron emission tomography (PET) in radiotherapy still requires careful evaluation as it becomes increasingly integrated into the radiotherapy planning process. Diagnosis and subsequent radiotherapy planning based solely upon X-ray CT are known to be less sensitive and specific for disease than PET imaging in non-small cell lung cancer. The CT images may not demonstrate the true extent of intrathoracic disease. To overcome this limitation, the direct use of combined PET/CT image data in the treatment planning process has been investigated. A small pilot study of five patients was carried out at the Royal Victoria Hospital, Belfast, following the installation of a GE Discovery LS PET/CT scanner. The initial aims were to investigate the system and to make preliminary clinical evaluations. The key issues that were addressed included: verification of PET/CT alignment, patient position and reproducibility for imaging and treatment; verification of CT numbers on the PET/CT systems for dose calculation, integrity of data transfer; radiation protection of staff, protocols for target volume delineation, and the implications for physiologically-gated PET and CT acquisitions. This paper reviews our practical experience, and technical problems are described.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 29 条
[1]  
Beyer T, 2004, J NUCL MED, V45, p25S
[2]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[3]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[4]  
Bradley JD, 2004, J NUCL MED, V45, p96S
[5]  
CARSON KJ, 2003, EUR J NUCL MED, V30, pS210
[6]   Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250
[7]   Improved survival in stage III non-small-cell lung cancer: Seven-year follow-up of cancer and leukemia group B (CALGB) 8433 trial [J].
Dillman, RO ;
Herndon, J ;
Seagren, SL ;
Eaton, WL ;
Green, MR .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (17) :1210-1215
[8]  
Erdi YE, 2004, J NUCL MED, V45, P1287
[9]  
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.3.CO
[10]  
2-B