The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging

被引:87
作者
Apostolakis, Dimitrios [1 ]
Brown, Jackie E. [2 ,3 ]
机构
[1] Maxillofacial Radiol & Diag Ctr, Khania, Crete, Greece
[2] Kings Coll London Inst, Dept Dent Radiol, London, England
[3] Guys Kings & St Thomas Hosp, London, England
关键词
anterior loop; cone beam computed tomography; inferior alveolar nerve; symphysis; INSTALLING ENDOSSEOUS IMPLANTS; COMPUTED-TOMOGRAPHY; MENTAL NERVE; PANORAMIC RADIOGRAPHS; MAXILLOFACIAL-RADIOLOGY; APPEARANCE; ACCURACY; REGION; RELIABILITY; DOSIMETRY;
D O I
10.1111/j.1600-0501.2011.02261.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Interforaminal implant surgery requires anatomical knowledge of the area and adequate information on the location of the various landmarks of significance such as the mental foramen, the anterior loop of the inferior alveolar nerve and the mandibular incisive canal. Cone beam computed tomography (CBCT) is a relatively new imaging modality that provides a multi-dimensional view of the facial skeleton with, in most instances, lower radiation dose to the patient compared to medical CT. The present study aims to use CBCT to identify and measure variation in the presence and extent of the anterior loop of the inferior alveolar nerve. This information may be used to provide recommendations to the surgeon without access to a 3D scan of the dento-alveolar region. Material and methods Ninety-three patients scanned with a Newtom VG device for a variety of clinical indications were included in this retrospective study. Using the multiplanar capabilities of the device's software the prevalence and length of the anterior loop was assessed. Results The results show that an anterior loop could be identified in 48% of the cases with a mean length (range) of 0.89 similar to mm (05.7). Conclusions In almost half of the surveyed cases an anterior loop was present. Even though in 95% of the study cases the loop was <3 similar to mm, a 100% safety margin in the placement of anterior mandibular implants, in the absence of a CBCT scan, would only be achieved with a distance of 6 similar to mm between the anterior border of the mental foramen and the most distal interforaminal implant fixture.
引用
收藏
页码:1022 / 1030
页数:9
相关论文
共 37 条
  • [1] Arzouman M J, 1993, Int J Oral Maxillofac Implants, V8, P295
  • [2] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [3] Bavitz J B, 1993, Int J Oral Maxillofac Implants, V8, P563
  • [4] The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: A literature review
    Greenstein, Gary
    Tarnow, Dennis
    [J]. JOURNAL OF PERIODONTOLOGY, 2006, 77 (12) : 1933 - 1943
  • [5] Branching patterns and intraosseous course of the mental nerve
    Hu, Kyung-Seok
    Yun, Hee-Sun
    Hur, Mi-Sun
    Kwon, Hyuk-Jae
    Abe, Shinichi
    Kim, Hee-Jin
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) : 2288 - 2294
  • [6] Hunt DR, 1999, INT J PERIODONT REST, V19, P165
  • [7] Ikeda K, 1996, AM J NEURORADIOL, V17, P579
  • [8] Appearance of the mandibular incisive canal on panoramic radiographs
    Jacobs, R
    Mraiwa, N
    van Steenberghe, D
    Sanderink, G
    Quirynen, M
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2004, 26 (04) : 329 - 333
  • [9] Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan
    Jacobs, R
    Mraiwa, N
    vanSteenberghe, D
    Gijbels, F
    Quirynen, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (05) : 322 - 327
  • [10] Kaya Y, 2008, INT J ORAL MAX IMPL, V23, P919