Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer

被引:0
|
作者
de Carvalho Froufe Andrade, Alberto Cesar Pereira
Caserotti, Paolo [2 ]
Pereira de Carvalho, Carlos Manuel
de Azevedo Abade, Eduardo Andre [1 ]
da Eira Sampaio, Antonio Jaime [1 ]
机构
[1] Univ Tras Os Montes & Alto Douro UTAD, Vila Real, Portugal
[2] Univ Southern Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
关键词
reproducibility; quadriceps; hamstring; peak torque; imbalance ratios; isokinetics; TEST-RETEST RELIABILITY; CON-TREX MJ; LEG STRENGTH; CYBEX NORM; REPRODUCIBILITY; PERFORMANCE; INTRAMACHINE; STABILITY; VELOCITY; FLEXORS;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23 +/- 3 years) underwent three testing sessions, two on the same day and a third, 7 days later. All sessions proceeded in the same order: five concentric contractions at 60 degrees s-1 followed by an isometric contraction (5 seconds) and five eccentric contractions (60 degrees s-1). The results of this study showed a high reproducibility in eccentric (0.95-0.97), concentric (0.95-0.96) and isometric (0.93-0.96), isokinetic strength for knee extensor and flexor muscles, thus indicating that the REV9000 isokinetic dynamometer can be used in future sports performance studies. A low-to-moderate reliability was found in the isokinetic strength bilateral ratios while the Hamstring:Quadricep concentric ratio showed moderate reliability. The highest reliability (>0.90) was observed in the dynamic control ratio (Hamstring eccentric:Quadricep concentric) which consequently confirms that it is a more valid indicator for imbalanced reciprocal parameters and can be used in rehabilitation and sports medicine.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [41] Intra-session reliability of knee flexion-extension muscle strength monitored using a functional electromechanical dynamometer in female soccer players
    Andrades-Ramirez, Oscar
    Ulloa-Diaz, David
    Castillo, Bryan Alfaro
    Saavedra-Ibaca, Vanessa
    Munoz-Bustos, Gustavo
    Chirosa-Rios, Luis-Javier
    FRONTIERS IN PHYSIOLOGY, 2025, 16
  • [42] Reliability and measurement precision of concentric-to-isometric and eccentric-to-isometric knee active joint position sense tests in uninjured physically active adults
    Clark, Nicholas C.
    Akins, Jonathan S.
    Heebner, Nicholas R.
    Sell, Timothy C.
    Abt, John P.
    Lovalekar, Mita
    Lephart, Scott M.
    PHYSICAL THERAPY IN SPORT, 2016, 18 : 38 - 45
  • [43] Reliability of Isometric Knee Extension Muscle Strength Measurement Using a Hand-held Dynamometer with a Belt: A Study of Test-retest Reliability in Healthy Elderly Subjects
    Katoh, Munenori
    Isozaki, Koji
    Sakanoue, Noboru
    Miyahara, Takuya
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2010, 22 (04) : 359 - 363
  • [44] Inter- and Intratester Reliability of Strength Measurement of Knee Extension and Flexion with a Modified Hand-Held Dynamometer in Healthy Subjects
    Schaefer, A.
    Dressel, M.
    Kaemmerer, S.
    Peschke, L.
    Braun, M. Ramos
    Schoettker-Koeniger, T.
    MANUELLE THERAPIE, 2015, 19 (01) : 38 - 44
  • [45] Reliability of Isometric Knee Extension Muscle Strength Measurements of Healthy Elderly Subjects Made with a Hand-held Dynamometer and a Belt
    Katoh, Munenori
    Isozaki, Koji
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (12) : 1855 - 1859
  • [46] Reliability and Validity of a Portable Traction Dynamometer in Knee-Strength Extension Tests: An Isometric Strength Assessment in Recreationally Active Men
    Garcia, Danielle
    Neto, Ivo Vieira de Sousa
    Monteiro, Yuri de Souza
    Magalhaes, Denis Pinheiro
    Ferreira, Gleison Miguel Lissemerki
    Grisa, Roberto
    Prestes, Jonato
    Rosa, Bruno Viana
    Abrahin, Odilon
    Martins, Tatiane Meire
    Vidal, Samuel Estevam
    Andrade, Rosimeire de Moura
    Celes, Rodrigo Souza
    Rolnick, Nicholas
    Nascimento, Dahan da Cunha
    HEALTHCARE, 2023, 11 (10)
  • [47] Test-retest Reliability of Isometric Knee Extension Muscle Strength Measurement using a Hand-held Dynamometer and a Belt: Study of Hemiplegic Patients
    Katoh, Munenori
    Asuma, Hitomi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 25 - 28
  • [48] Reproducibility of concentric and eccentric isokinetic multi-joint leg extension measurements using the IsoMed 2000-system
    Dirnberger, Johannes
    Huber, Christoph
    Hoop, Dennis
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2013, 21 (03) : 195 - 202
  • [49] TEST-RETEST RELIABILITY OF ECCENTRIC PEAK TORQUE VALUES FOR SHOULDER MEDIAL AND LATERAL ROTATION USING THE BIODEX ISOKINETIC DYNAMOMETER
    FRISIELLO, S
    GAZAILLE, A
    OHALLORAN, J
    PALMER, ML
    WAUGH, D
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 19 (06): : 341 - 344
  • [50] Intra- and Inter-Rater Reliability of a Well-Used and a Less-Used IsoMed 2000 Dynamometer for Knee Flexion and Extension Peak Torque Measurements in a Concentric Test in Athletes
    Kocahan, Tugba
    Akinoglu, Bihter
    Yilmaz, Ayfer Ezgi
    Rosemann, Thomas
    Knechtle, Beat
    APPLIED SCIENCES-BASEL, 2021, 11 (11):