Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer

被引:0
|
作者
de Carvalho Froufe Andrade, Alberto Cesar Pereira
Caserotti, Paolo [2 ]
Pereira de Carvalho, Carlos Manuel
de Azevedo Abade, Eduardo Andre [1 ]
da Eira Sampaio, Antonio Jaime [1 ]
机构
[1] Univ Tras Os Montes & Alto Douro UTAD, Vila Real, Portugal
[2] Univ Southern Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
关键词
reproducibility; quadriceps; hamstring; peak torque; imbalance ratios; isokinetics; TEST-RETEST RELIABILITY; CON-TREX MJ; LEG STRENGTH; CYBEX NORM; REPRODUCIBILITY; PERFORMANCE; INTRAMACHINE; STABILITY; VELOCITY; FLEXORS;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23 +/- 3 years) underwent three testing sessions, two on the same day and a third, 7 days later. All sessions proceeded in the same order: five concentric contractions at 60 degrees s-1 followed by an isometric contraction (5 seconds) and five eccentric contractions (60 degrees s-1). The results of this study showed a high reproducibility in eccentric (0.95-0.97), concentric (0.95-0.96) and isometric (0.93-0.96), isokinetic strength for knee extensor and flexor muscles, thus indicating that the REV9000 isokinetic dynamometer can be used in future sports performance studies. A low-to-moderate reliability was found in the isokinetic strength bilateral ratios while the Hamstring:Quadricep concentric ratio showed moderate reliability. The highest reliability (>0.90) was observed in the dynamic control ratio (Hamstring eccentric:Quadricep concentric) which consequently confirms that it is a more valid indicator for imbalanced reciprocal parameters and can be used in rehabilitation and sports medicine.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [31] Test-Retest Reliability of Concentric and Eccentric Muscle Strength in Knee Flexion-Extension Controlled by Functional Electromechanical Dynamometry in female Soccer
    Andrades-Ramirez, Oscar
    Ulloa-Diaz, David
    Rodriguez-Perea, Angela
    Araya-Sierralta, Sergio
    Guede-Rojas, Francisco
    Munoz-Bustos, Gustavo
    Chirosa-Rios, Luis-Javier
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [32] Reliability assessment of isometric knee extension measurements with a computer-assisted hand-held dynamometer
    Roebroeck, ME
    Harlaar, J
    Lankhorst, GJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (04): : 442 - 448
  • [33] Reciprocal Versus Nonreciprocal Assessment of Knee Flexors and Extensors in Concentric Actions Using the CON-TREX Multijoint Isokinetic Dynamometer: A Reliability Study
    Bliss, Alex
    Dekerle, Jeanne
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2019, 23 (02) : 118 - 123
  • [34] Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
    Roth, Ralf
    Donath, Lars
    Kurz, Eduard
    Zahner, Lukas
    Faude, Oliver
    PHYSICAL THERAPY IN SPORT, 2017, 24 : 26 - 31
  • [35] RELIABILITY OF 1RM KNEE EXTENSION TEST STARTING FROM ECCENTRIC AND CONCENTRIC PHASES
    Cosenza, P. I. C.
    Carpenter, C. S.
    Gomes, P. S. C.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S301 - S301
  • [36] Intrarater Reliability of Muscle Strength and Hamstring to Quadriceps Strength Imbalance Ratios During Concentric, Isometric, and Eccentric Maximal Voluntary Contractions Using the Isoforce Dynamometer
    Mau-Moeller, Anett
    Gube, Martin
    Felser, Sabine
    Feldhege, Frank
    Weippert, Matthias
    Husmann, Florian
    Tischer, Thomas
    Bader, Rainer
    Bruhn, Sven
    Behrens, Martin
    CLINICAL JOURNAL OF SPORT MEDICINE, 2019, 29 (01): : 69 - 77
  • [37] TEST-RETEST RELIABILITY OF ISOKINETIC KNEE EXTENSION AND FLEXION TORQUE MEASUREMENTS IN PERSONS WITH SPASTIC HEMIPARESIS
    TRIPP, EJ
    HARRIS, SR
    PHYSICAL THERAPY, 1991, 71 (05): : 390 - 396
  • [38] Reliability of a Clinical Test for Measuring Eccentric Knee Flexor Strength Using a Handheld Dynamometer
    Oliveira, Gabriel dos Santos
    Ribeiro-Alvares, Joao Breno de Araujo
    de Lima-e-Silva, Felipe Xavier
    Rodrigues, Rodrigo
    Vaz, Marco Aurelio
    Baroni, Bruno Manfredini
    JOURNAL OF SPORT REHABILITATION, 2022, 31 (01) : 115 - 119
  • [39] Routine monitoring of isometric knee extension strength in patients with muscle impairments using a new portable device: cross-validation against a standard isokinetic dynamometer
    Hogrel, Jean-Yves
    Benveniste, Olivier
    Bachasson, Damien
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (01)
  • [40] INTERSESSION RELIABILITY OF THE INTERPOLATED TWITCH TECHNIQUE APPLIED DURING ISOMETRIC, CONCENTRIC, AND ECCENTRIC ACTIONS OF THE HUMAN KNEE EXTENSOR MUSCLES
    Behrens, Martin
    Husmann, Florian
    Gube, Martin
    Felser, Sabine
    Weippert, Matthias
    Bruhn, Sven
    Zschorlich, Volker
    Mau-Moeller, Anett
    MUSCLE & NERVE, 2017, 56 (02) : 324 - 327