Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer

被引:0
|
作者
de Carvalho Froufe Andrade, Alberto Cesar Pereira
Caserotti, Paolo [2 ]
Pereira de Carvalho, Carlos Manuel
de Azevedo Abade, Eduardo Andre [1 ]
da Eira Sampaio, Antonio Jaime [1 ]
机构
[1] Univ Tras Os Montes & Alto Douro UTAD, Vila Real, Portugal
[2] Univ Southern Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
关键词
reproducibility; quadriceps; hamstring; peak torque; imbalance ratios; isokinetics; TEST-RETEST RELIABILITY; CON-TREX MJ; LEG STRENGTH; CYBEX NORM; REPRODUCIBILITY; PERFORMANCE; INTRAMACHINE; STABILITY; VELOCITY; FLEXORS;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23 +/- 3 years) underwent three testing sessions, two on the same day and a third, 7 days later. All sessions proceeded in the same order: five concentric contractions at 60 degrees s-1 followed by an isometric contraction (5 seconds) and five eccentric contractions (60 degrees s-1). The results of this study showed a high reproducibility in eccentric (0.95-0.97), concentric (0.95-0.96) and isometric (0.93-0.96), isokinetic strength for knee extensor and flexor muscles, thus indicating that the REV9000 isokinetic dynamometer can be used in future sports performance studies. A low-to-moderate reliability was found in the isokinetic strength bilateral ratios while the Hamstring:Quadricep concentric ratio showed moderate reliability. The highest reliability (>0.90) was observed in the dynamic control ratio (Hamstring eccentric:Quadricep concentric) which consequently confirms that it is a more valid indicator for imbalanced reciprocal parameters and can be used in rehabilitation and sports medicine.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [1] Eccentric and concentric isokinetic knee flexion and extension: A reliability study using the Cybex 6000 dynamometer
    Li, RCT
    Wu, Y
    Maffulli, N
    Chan, KM
    Chan, JLC
    BRITISH JOURNAL OF SPORTS MEDICINE, 1996, 30 (02) : 156 - 160
  • [2] RELIABILITY OF ECCENTRIC ISOKINETIC KNEE FLEXION AND EXTENSION MEASUREMENTS
    STEINER, LA
    HARRIS, BA
    KREBS, DE
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1993, 74 (12): : 1327 - 1335
  • [3] Concentric and eccentric isokinetic knee extension: A reproducibility study using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (01) : 31 - 35
  • [4] Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer
    Maffiuletti, Nicola A.
    Bizzini, Mario
    Desbrosses, Kevin
    Babault, Nicolas
    Munzinger, Urs
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2007, 27 (06) : 346 - 353
  • [5] Reliability of isokinetic concentric and eccentric knee and elbow extension and flexion in 9/10 year old boys
    Deighan, MA
    Croix, MBAD
    Armstrong, N
    ISOKINETICS AND EXERCISE SCIENCE, 2003, 11 (02) : 109 - 115
  • [6] Reproducibility for isometric and isokinetic maximum knee flexion and extension measurements using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Wiesinger, Hans-Peter
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (03) : 149 - 153
  • [7] RELIABILITY OF ISOKINETIC ECCENTRIC AND CONCENTRIC KNEE EXTENSIONS
    CARTER, CL
    BEKENDAM, JT
    CASSIDY, ML
    ROGOUSKI, MA
    PHYSICAL THERAPY, 1987, 67 (05): : 752 - 753
  • [8] The effects of normalization method on antagonistic activity patterns during eccentric and concentric isokinetic knee extension and flexion
    Kellis, E
    Baltzopoulos, V
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (04) : 235 - 245
  • [9] Electrical manifestations of muscle fatigue during concentric and eccentric isokinetic knee flexion-extension movements
    Molinari, Filippo
    Knaflitz, Marco
    Bonato, Paolo
    Actis, Maria Vittoria
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1309 - 1316
  • [10] Reliability of concentric and eccentric torque during isokinetic knee extension in post-stroke hemiparesis
    Clark, DJ
    Condliffe, EG
    Patten, C
    CLINICAL BIOMECHANICS, 2006, 21 (04) : 395 - 404