Performance of Spin-Echo and Gradient-Echo T1-Weighted Sequences for Evaluation of Dural Venous Sinus Thrombosis and Stenosis

被引:22
|
作者
Saindane, Amit M. [1 ,2 ]
Mitchell, Bradford C. [1 ,2 ]
Kang, Jian [1 ,2 ,3 ]
Desai, Nilesh K. [1 ,2 ]
Dehkharghani, Seena [1 ,2 ]
机构
[1] Emory Univ Hosp, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Biostat & Bioinformat, Atlanta, GA 30322 USA
关键词
idiopathic intracranial hypertension; MR venography; sensitivity and specificity; venous sinus thrombosis; IDIOPATHIC INTRACRANIAL HYPERTENSION; TIME-OF-FLIGHT; 3-DIMENSIONAL MR VENOGRAPHY; ENHANCED MR; MAGNETIC-RESONANCE; CEREBRAL VEINS; SYSTEM; OBSTRUCTION; DIAGNOSIS; UPDATE;
D O I
10.2214/AJR.12.9095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Dural venous sinus abnormalities are clinically important but can potentially be overlooked using various MRI techniques. This study evaluates the diagnostic accuracy of spin-echo (SE) T1-weighted imaging, 3D gradient-recalled echo (GRE) T1-weighted imaging, and contrast-enhanced MR venography (MRV) for the detection of dural venous sinus thrombosis and transverse sinus (TS) stenosis. MATERIALS AND METHODS. Seventy-three patients underwent MRI evaluation with unenhanced and contrast-enhanced axial SE T1-weighted imaging, contrast-enhanced sagittal 3D GRE T1-weighted imaging, and contrast-enhanced MRV sequences. Three neuroradiologists each evaluated these 219 total datasets in a randomized blinded fashion for the presence or absence of TS stenosis and for dural venous sinus thrombosis in each of 10 venous sinus segments (730 total segments). Diagnostic performance characteristics and kappa statistics were calculated for each technique. RESULTS. Thirteen patients (37 segments) had suspected dural venous sinus thrombosis by one or more readers; of those 13 patients, nine (23 segments) were thought to have definite thrombosis on contrast-enhanced MRV. Compared with contrast-enhanced MRV, the positive predictive value (PPV) and negative predictive value (NPV) for thrombosis were 60% and 97%, respectively, for both unenhanced and contrast-enhanced SE T1-weighted imaging and 100% and 98% for 3D GRE T1-weighted imaging. Kappa values calculated per venous segment were as follows: 0.41 for SE T1-weighted imaging, 0.72 for 3D GRE T1-weighted imaging, and 0.95 for contrast-enhanced MRV. Thirty patients (58 segments) had TS stenosis suspected by one or more readers; of those 30 patients, TS stenosis was deemed to be definite on contrast-enhanced MRV in 25 patients (50 segments). Compared with contrast-enhanced MRV, the PPV and NPV were 75% and 80%, respectively, for SE T1-weighted imaging and 91% and 92% for 3D GRE T1-weighted imaging for the detection of stenosis. Kappa values calculated per patient were -0.038 for SE T1-weighted imaging, 0.58 for 3D GRE T1-weighted imaging, and 0.98 for contrast-enhanced MRV. CONCLUSION. Contrast-enhanced 3D GRE T1-weighted imaging is superior to SE T1-weighted imaging for the detection of dural venous sinus thrombosis and TS stenosis but does not substitute for dedicated MRV. Hyperintensity on unenhanced SE T1-weighted imaging is unreliable for the detection of dural venous sinus thrombosis.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 50 条
  • [1] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29
  • [2] Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images
    Maeder, Yael
    Dunet, Vincent
    Richard, Raphael
    Becce, Fabio
    Omoumi, Patrick
    RADIOLOGY, 2018, 286 (03) : 853 - 864
  • [3] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    Aymerich, F. X.
    Auger, C.
    Alcaide-Leon, P.
    Pareto, D.
    Huerga, E.
    Corral, J. F.
    Mitjana, R.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1361 - 1368
  • [4] LEFT-VENTRICULAR THROMBI - EVALUATION WITH SPIN-ECHO AND GRADIENT-ECHO MR IMAGING
    JUNGEHULSING, M
    SECHTEM, U
    THEISSEN, P
    HILGER, HH
    SCHICHA, H
    RADIOLOGY, 1992, 182 (01) : 225 - 229
  • [5] DETECTION OF HEMORRHAGE IN ACUTE CEREBRAL INFARCTION EVALUATION WITH SPIN-ECHO AND GRADIENT-ECHO MRI
    WEINGARTEN, K
    FILIPPI, C
    ZIMMERMAN, RD
    DECK, MDF
    CLINICAL IMAGING, 1994, 18 (01) : 43 - 55
  • [6] Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer
    Aprile, I
    Lavaroni, A
    Scott, CA
    Budai, R
    Beltrami, CA
    Fabris, G
    RIVISTA DI NEURORADIOLOGIA, 2001, 14 (03): : 259 - 265
  • [7] Comparison of Spin-Echo T1-and T2-Weighted and Gradient-Echo T1-Weighted Images at 3T in Evaluating Very Preterm Neonates at Term-Equivalent Age
    Sarikaya, B.
    McKinney, A. M.
    Spilseth, B.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1098 - 1103
  • [8] Stomach diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences
    Marcos, HB
    Semelka, RC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (06): : 950 - 960
  • [9] Comparison of susceptibility-weighted angiography (SWAN) and T2 gradient-echo sequences for the detection of acute cerebral venous thrombosis
    Boukobza, Monique
    Guinebert, Sylvain
    Laissy, Jean-Pierre
    NEURORADIOLOGY JOURNAL, 2023, 36 (02) : 148 - 157
  • [10] Dependence of gradient-echo and spin-echo BOLD fMRI at 4T on diffusion weighting
    Michelich, Charles R.
    Song, Allen W.
    MacFall, James R.
    NMR IN BIOMEDICINE, 2006, 19 (05) : 566 - 572