Validation of the Willems badge diffusive sampler for nitrogen dioxide determinations in occupational environments

被引:13
作者
Hagenbjörk-Gustafsson, A
Lindahl, R
Levin, JO
Karlsson, D
机构
[1] Natl Inst Working Life, Programme Chem Exposure Assessment, S-90713 Umea, Sweden
[2] Umea Univ, Dept Environm Hlth, S-90187 Umea, Sweden
关键词
D O I
10.1039/b107844e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Willems badge, a diffusive sampler for nitrogen dioxide, has previously been validated for ambient air measurements. This paper describes the laboratory and field validation of the Willems badge for personal sampling under working environment conditions. The mean sampling rate in the laboratory tests was 46 ml min(-1) with an RSD of 12%. No statistically significant effects on sampling rate of the sampling time, concentration of NO2 or relative humidity were found. A slightly decreased sampling rate was observed at low wind velocity. This was also confirmed during static sampling, which makes the sampler less appropriate for static sampling indoors. No back diffusion was observed. Storage of the samplers for two weeks before or after exposure did not affect the sampling rate. Our analysis is based on a modified colorimetric method, performed by FIA (flow injection analysis). This technique was compared to ion chromatography analysis. The use of ion chromatography lowered the detection limit from 11 to 2 mug m(-3) for an 8 h sample. and furthermore enabled the detection of other anions. In conclusion, the diffusive sampler was found to per-form well for personal measurements in industrial environments.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 15 条
[1]   INHALATIONAL INJURIES PRODUCED BY SMOKE AND NITROGEN-DIOXIDE [J].
AINSLIE, G .
RESPIRATORY MEDICINE, 1993, 87 (03) :169-174
[2]   INDOOR AIR-POLLUTION - NO, NO2, CO, AND CO2 [J].
ALBERTS, WM .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (02) :289-295
[3]   Monitoring the ambient environment with diffusive samplers: theory and practical considerations [J].
Brown, RH .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (01) :1-9
[4]  
CARLSON R, 1992, DESIGN OPTIMIZATION, V8
[5]  
*CEN EUR COMM STAN, 1995, 838 CEN EN EUR COMM
[6]   TOXICITY OF NITROGEN-DIOXIDE - AN INTRODUCTION [J].
ELSAYED, NM .
TOXICOLOGY, 1994, 89 (03) :161-174
[7]   THE EFFECTS OF WIND-SPEED AND TURBULENCE ON THE PERFORMANCE OF DIFFUSION TUBE SAMPLERS [J].
GAIR, AJ ;
PENKETT, SA .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (18) :2529-2533
[8]   Validation of a diffusive sampler for NO2 [J].
Hagenbjörk-Gustafsson, A ;
Lindahl, R ;
Levin, JO ;
Karlsson, D .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (04) :349-352
[9]   Measurements of indoor and outdoor nitrogen dioxide concentrations using a diffusive sampler [J].
HagenbjorkGustafsson, A ;
Forsberg, B ;
Hestvik, G ;
Karlsson, D ;
Wahlberg, S ;
Sandstrom, T .
ANALYST, 1996, 121 (09) :1261-1264
[10]  
HELLEDAY R, 1995, THESIS UMEA U