An investigation on the fatigue behavior of DCB specimen bonded with aluminum foam at Mode III

被引:1
|
作者
Lee, J. H. [1 ]
Cho, J. U. [2 ]
Zhao, G. [3 ]
Cho, C. [4 ]
机构
[1] Kongju Univ, Grad Sch, Dept Mech Engn, Cheonan, South Korea
[2] Kongju Univ, Div Mech & Automot Engn, Cheonan, South Korea
[3] Xi An Jiao Tong Univ, Sch Aerosp, Xian, Peoples R China
[4] Inha Univ, Dept Mech Engn, Inchon, South Korea
基金
新加坡国家研究基金会;
关键词
Mode III; Aluminum foam; Adhesive; DCB specimen; Specimen thickness; Single-butt method; Fatigue; CANTILEVER BEAM; JOINTS;
D O I
10.1007/s12206-016-0915-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Aluminum foam with its excellent physical and mechanical characteristics is a lightweight metallic material used with good quality in vehicle bumpers, internal shock absorbers on planes, as materials for vessel joints etc. On the contrary, when aluminum foam is used without sufficient investigation, there is the likelihood of damage or destruction of the machine or mechanical structure, and in extreme case it may cause to human casualties. This study aims to analyze the characteristics of adhesive structures with aluminum foam for the closed-type aluminum foam used primarily as shock absorbers. The fatigue analyses of the DCB test specimens at mode III with aluminum foam are verified through a fatigue experiment. As the analysis results, test specimen models with the thicknesses (t) of 35 mm, 45 mm and 55 mm showed the peak load occurrence approximately after the progress from 0 to 50 cycles. And afterwards the load gradually decreased as the cycles increased. The peak loads for each DCB test specimens were +/- 0.80 kN for the specimen thickness(t) of 35 mm, +/- 0.98 kN for the specimen thickness(t) of 45 mm and +/- 1.18 kN for the specimen thickness(t) of 55 mm. It is also shown that the peak load occurring on the specimen increased as specimen thickness increased. These study results are compared with the specimen thickness of 35 mm model as the basis. When the specimen thickness is increased as much as 10 mm, the peak load is increased approximately 1.25 times. When the specimen thickness is also increased as much as 20 mm, the peak load is increased 1.5 times. The analysis data and the real experiment data showed similar results each other. Therefore, it can be thought that the analysis data is applicable in real field. And it is estimated that the mechanical characteristics of the DCB test specimen at mode III during the fatigue load conditions can be systematically and efficiently analyzed.
引用
收藏
页码:4475 / 4478
页数:4
相关论文
共 50 条
  • [1] An investigation on the fatigue behavior of DCB specimen bonded with aluminum foam at Mode III
    J. H. Lee
    J. U. Cho
    G. Zhao
    C. Cho
    Journal of Mechanical Science and Technology, 2016, 30 : 4475 - 4478
  • [2] A Fracture Study on the Bonded DCB Specimen of the Mode III Type with Aluminum Foam
    Lee, Jung-Ho
    Cho, Jae-Ung
    Cheon, Seong-Sik
    COMPOSITES RESEARCH, 2015, 28 (04): : 191 - 196
  • [3] Experimental Study on the Fatigue Crack Propagation Behavior of DCB Specimen with Aluminum Foam
    Han, Moon-Sik
    Choi, Hae-Kyu
    Choz, Jae-Ung
    Cho, Chong-Du
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (08) : 1395 - 1399
  • [4] Experimental study on the fatigue crack propagation behavior of DCB specimen with aluminum foam
    Moon-Sik Han
    Hae-Kyu Choi
    Jae-Ung Cho
    Chong-Du Cho
    International Journal of Precision Engineering and Manufacturing, 2013, 14 : 1395 - 1399
  • [5] A FATIGUE FRACTURE STUDY ON TDCB ALUMINUM FOAM SPECIMEN OF TYPE MODE III BONDED WITH ADHESIVE
    Lee, J. H.
    Cho, J. U.
    ARCHIVES OF METALLURGY AND MATERIALS, 2017, 62 (02) : 1359 - 1362
  • [6] Study on the fatigue experiment of TDCB aluminum foam specimen bonded with adhesive
    Sung-Soo Kim
    Moon-Sik Han
    Jae-Ung Cho
    Chong-Du Cho
    International Journal of Precision Engineering and Manufacturing, 2013, 14 : 1791 - 1795
  • [7] Study on the fatigue experiment of TDCB aluminum foam specimen bonded with adhesive
    Kim, Sung-Soo
    Han, Moon-Sik
    Cho, Jae-Ung
    Cho, Chong-Du
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (10) : 1791 - 1795
  • [8] Fracture behavior on the structures of DCB jointed with aluminum foam in tearing mode
    Lee, Jung Ho
    Cho, Jae Ung
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2016, 17 (07) : 897 - 902
  • [9] Fracture behavior of adhesive interface at TDCB aluminum foam specimen with the type of Mode III
    Jung Ho Lee
    Jae Ung Cho
    International Journal of Precision Engineering and Manufacturing, 2017, 18 : 705 - 710
  • [10] Fracture behavior of adhesive interface at TDCB aluminum foam specimen with the type of Mode III
    Lee, Jung Ho
    Cho, Jae Ung
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2017, 18 (05) : 705 - 710