Aortic coarctation reconstructed by resection and homograft replacement in the 1950s:: Long-term outcome 40 years after operation

被引:3
作者
Hüttl, T
Balázs, G
Entz, L
Hüttl, K
Bodor, E
Szabolcs, Z
机构
[1] Semmelweis Univ, Dept Cardiovasc Surg, H-1122 Budapest, Hungary
[2] Heim Pal Childrens Hosp, Dept Radiol, Budapest, Hungary
关键词
D O I
10.1016/S0003-4975(01)03628-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since the first successful repair of aortic coarctation by Dr Clarence Crafoord in 1945, there are few data regarding late follow-up of homografts in this position. Between 1957 and 1959, 7 patients underwent surgical correction of aortic coarctation by Professor József Kudász at the Department of Cardiovascular Surgery, Semmelweis University, using freeze-dried aortic homograft. We were able to locate 4 of these patients and found no significant complications due to the operation. We report on this 40-year follow-up of implanted aortic homograft. © 2002 by The Society of Thoracic Surgeons.
引用
收藏
页码:1678 / 1680
页数:3
相关论文
共 4 条
[1]   ANEURYSMATIC DILATATION OF AN AORTIC HOMOGRAFT MORE THAN 30 YEARS AFTER IMPLANTATION INTO THE THORACIC AORTA [J].
CORNELISSEN, PHJ ;
HAMERLIJNCK, RP ;
VERMEULEN, FE .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (08) :447-448
[2]  
CRAFOORD C, 1945, J THORAC SURG, V14, P347
[3]   PRELIMINARY OBSERVATIONS ON THE USE OF HUMAN ARTERIAL GRAFTS IN THE TREATMENT OF CERTAIN CARDIOVASCULAR DEFECTS [J].
GROSS, RE ;
HURWITT, ES ;
BILL, AH ;
PEIRCE, EC .
NEW ENGLAND JOURNAL OF MEDICINE, 1948, 239 (16) :578-579
[4]  
vonSegesser LK, 1997, J CARDIAC SURG, V12, P256