Syndesmosis reduction by computer-assisted orthopaedic surgery with navigation: Feasibility and accuracy in a cadaveric study

被引:7
作者
Dubois-Ferriere, Victor [1 ]
Gamulin, Axel [1 ]
Chowdhary, Ashwin [2 ]
Fasel, Jean [3 ]
Stern, Richard [2 ]
Assal, Mathieu [2 ,4 ]
机构
[1] Univ Hosp Geneva, Div Orthopaed & Trauma Surg, Geneva, Switzerland
[2] Clin La Colline, Ctr Surg Foot & Ankle, Geneva, Switzerland
[3] Ctr Med Univ Geneva, Div Anat, Geneva, Switzerland
[4] Ctr Med Univ Geneva, Fac Med, Geneva, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2016年 / 47卷 / 12期
关键词
Syndesmosis; Computer-assisted; Reduction; Navigation; Cadaver; ANKLE FRACTURES; TIBIOFIBULAR SYNDESMOSIS; SCREW FIXATION; MALREDUCTION; INJURIES; CT; STABILIZATION; PREDICTORS; ISO-C-3D;
D O I
10.1016/j.injury.2016.10.009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Syndesmotic disruption may be difficult to reduce and fix, and malreduction is associated with inferior outcomes. Intraoperative computed tomography (CT) can provide accurate assessment of syndesmotic reduction. We hypothesized that three-dimensional (3-D) computer-assisted orthopaedic surgery (CAOS) with navigation of syndesmotic reduction could avoid malreduction. Our goal was to assess feasibility and accuracy of such a technic in a cadaveric study. Method: Eleven through-the-knee cadaveric specimens were used. Ankle CT as control was obtained prior to intervention. The syndesmosis was destabilized by sectioning the tibiofibular ligaments, producing a malreduction temporarily fixed with a Kirschner wire (K-wire). With reference base fixed to the tibia an acquisition scan was made. A K-wire was fixed to the fibula. The K-wire holding the syndesmosis malreduced was removed. The fibula was reduced within the syndesmosis under 3-D CAOS using a navigated K-wire. Once optimal position was obtained by referencing control images, the syndesmosis was fixed with a 3.5 mm screw. A CT scan was performed to assess quality of reduction. Results: Position of the fibula in control and post-reduction CT scans showed a mean anterior-posterior displacement of 0.74 (+/- 0.62) mm. The medial-lateral position measured a mean displacement of 0.68 (+/- 0.76) mm. Rotation of the fibula revealed a mean difference of 0.99 degrees (+/- 0.73). Conclusion: In this cadaveric study, CAOS with navigation allowed for very accurate syndesmosis reduction. This appears to be a promising technique to be confirmed by clinical study. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2694 / 2699
页数:6
相关论文
共 25 条
[1]   The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures [J].
Atesok, K. ;
Finkelstein, J. ;
Khoury, A. ;
Peyser, A. ;
Weil, Y. ;
Liebergall, M. ;
Mosheiff, R. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (10) :1163-1169
[2]   Computer-assisted Trauma Surgery [J].
Atesok, Kivanc ;
Schemitsch, Emil H. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (05) :247-258
[3]   Radiographic measurement of the distal tibiofibular syndesmosis has limited use [J].
Beamer, A ;
van Hemert, WLW ;
Niesing, R ;
Entius, CAC ;
Ginai, AZ ;
Mulder, PGH ;
Swierstra, BA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :227-234
[4]  
CHISSELL HR, 1995, J BONE JOINT SURG BR, V77B, P435
[5]   Normal Tibiofibular Relationships at the Syndesmosis on Axial CT Imaging [J].
Dikos, Gregory D. ;
Heisler, Jason ;
Choplin, Robert H. ;
Weber, Timothy G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (07) :433-438
[6]  
Dubois-Ferriere V, 2014, Rev Med Suisse, V10, P562
[7]   Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation [J].
Eckardt, Henrik ;
Lind, Marianne .
FOOT & ANKLE INTERNATIONAL, 2015, 36 (07) :764-773
[8]   Outcome after Unstable Ankle Fracture: Effect of Syndesmotic Stabilization [J].
Egol, Kenneth A. ;
Pahk, Brian ;
Walsh, Michael ;
Tejwani, Nirmal C. ;
Davidovitch, Roy I. ;
Koval, Kenneth J. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (01) :7-11
[9]   Predictors of a Persistent Dislocation After Reduction of Syndesmotic Injuries Detected With Intraoperative Three-Dimensional Imaging [J].
Franke, Jochen ;
von Recum, Jan ;
Suda, Arnold J. ;
Vetter, Sven ;
Gruetzner, Paul Alfred ;
Wendl, Klaus .
FOOT & ANKLE INTERNATIONAL, 2014, 35 (12) :1323-1328
[10]   Intraoperative Three-Dimensional Imaging in the Treatment of Acute Unstable Syndesmotic Injuries [J].
Franke, Jochen ;
von Recum, Jan ;
Suda, Arnold J. ;
Gruetzner, Paul Alfred ;
Wendl, Klaus .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (15) :1386-1390