The radial angular filter array (RAFA) consists of a series of radially-distributed micro-machined channels, where the long axes of the channels converge at a focal point. The high aspect ratio of each channel provides a means to reject photons with trajectories outside the acceptance angle of the channel. The output of the RAFA represents the angular distribution of photons emitted from the focal point. A series of RAFAs were designed, fabricated, and tested to evaluate the impact of device geometry, inter-channel cross talk, achromaticity, and channel leakage on device performance. As an application example, an RAFA was used together with an imaging spectrometer to capture angle-resolved spectra of turbid samples. (C) 2013 Optical Society of America
引用
收藏
页码:2928 / 2941
页数:14
相关论文
共 26 条
  • [21] Determination of particle size by using the angular distribution of backscattered light as measured with low-coherence interferometry
    Wax, A
    Yang, CH
    Backman, V
    Kalashnikov, M
    Dasari, RR
    Feld, MS
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (04): : 737 - 744
  • [22] Weyrich T., Measuring skin reflectance and subsurface scattering
  • [23] Angle-Resolved Spectroscopy: a Tissue-Mimicking Phantom Study
    Zhang, Yan
    Vasefi, Fartash
    Chamson-Reig, Astrid
    Najiminainia, Mohamadreza
    Kaminska, Bozena
    Carson, Jeffrey J. L.
    [J]. OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXIII, 2012, 8221
  • [24] Use of a Radial Angular Filter Array to Estimate the Position of an Optically Attenuating Object within a Turbid Medium
    Zhang, Yan
    Vasefi, Fartash
    Najiminaini, Mohamadreza
    Kaminska, Bozena
    Carson, Jeffrey J. L.
    [J]. BIOMEDICAL APPLICATIONS OF LIGHT SCATTERING VI, 2012, 8230
  • [25] Optimization of Radial Angular Filter Arrays for Detecting the Angular Distribution of Light
    Zhang, Yan
    Vasefi, Fartash
    Najiminaini, Mohamadreza
    Kaminska, Bozena
    Carson, Jeffrey J. L.
    [J]. OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894
  • [26] Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology
    Zhu, Yizheng
    Terry, Neil G.
    Woosley, John T.
    Shaheen, Nicholas J.
    Wax, Adam
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)