AC losses of prototype HTS transmission cables

被引:11
作者
Lue, JW [1 ]
Demko, JA
Dresner, L
Hughey, RL
Sinha, U
Tolbert, JC
Olsen, SK
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[2] Southwire Co, Carrollton, GA USA
[3] Tech Univ Denmark, Dept Elect Power Engn, DK-2800 Lyngby, Denmark
关键词
D O I
10.1109/77.783323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Since 1995 Southwire Company and Oak Ridge National Laboratory (ORNL) have jointly designed, built, and tested nine, 1-m long, high temperature superconducting (HTS) transmission cable prototypes. This paper summarizes the AC loss measurements of five of the cables not reported elsewhere, and compares the losses with each other and with theory developed by Dresner, Losses were measured with both a calorimetric and an electrical technique. Because of the broad resistive transition of the HTS tapes, the cables can be operated stably beyond their critical currents. The AC losses were measured in this region as well as below critical currents. Dresner's theory takes into account the broad resistive transition of the HTS tapes and calculates the AC losses both below and above the critical current. The two sets of AC loss data agree with each other and with the theory quite well. In particular, at low currents of incomplete penetration, the loss data agree with the theoretical prediction of hysteresis loss based on only the outer two layers carrying the total current.
引用
收藏
页码:416 / 419
页数:4
相关论文
共 5 条
[1]  
DEMKO JA, IN PRESS ADV CRYOGEN, V43
[2]   Hysteresis losses in power-law cryoconductors .2. [J].
Dresner, L .
APPLIED SUPERCONDUCTIVITY, 1996, 4 (7-8) :337-341
[3]  
DRESNER L, 1998, ICMC98 U TWENTE NETH
[4]  
LUE JW, 1997, IEEE T APPL SUPERCON, V7, P303
[5]   CALORIMETRIC AC LOSS MEASUREMENT IN THE MICROWATT RANGE - A NEW SIMPLIFIED MEASURING TECHNIQUE [J].
SCHMIDT, C .
CRYOGENICS, 1994, 34 (01) :3-8