Atlas-based segmentation of bone structures to support the virtual planning of hip operations

被引:35
作者
Ehrhardt, J
Handels, H
Malina, T
Strathmann, B
Plötz, W
Pöppl, SJ
机构
[1] Med Univ Lubeck, Inst Med Informat, D-23538 Lubeck, Germany
[2] Med Univ Lubeck, Dept Orthopaed Surg, D-23538 Lubeck, Germany
关键词
anatomical atlas; virtual operation planning; atlas based segmentation; registration;
D O I
10.1016/S1386-5056(01)00212-X
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Two 3-D digitised atlases of a female and a male pelvis were generated to support the virtual 3-D planning of hip operations. The anatomical atlases were designed to replace the interactive, time-consuming pre-processing steps for the virtual operation planning. Each atlas consists of a labelled reference CT data set and a set of anatomical point landmarks. The paper, presents methods for the automatic transfer of these anatomical labels to an individual patient data set. The labelled patient data are used to generate 3-D models of the patient's bone structures. Besides the anatomical labelling, the determination of measures, like angles, distances or sizes of contact areas, is important for the planning of hip operations. Thus, algorithms for the automatic computation, of orthopaedic parameters were implemented. A first evaluation of the presented atlas-based segmentation method shows a correct labelling of 98.5% of the bony voxels. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:439 / 447
页数:9
相关论文
共 24 条
  • [1] ACKERMANN MJ, 1998, 9 WORLD C MED INF ME, P1030
  • [2] [Anonymous], 1998, J COMPUT ASSIST TOMO
  • [3] MULTIRESOLUTION ELASTIC MATCHING
    BAJCSY, R
    KOVACIC, S
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 46 (01): : 1 - 21
  • [4] Barrett W A, 1997, Med Image Anal, V1, P331, DOI 10.1016/S1361-8415(97)85005-0
  • [5] BroNielsen M, 1996, LECT NOTES COMPUT SC, V1131, P267
  • [6] 3D BRAIN MAPPING USING A DEFORMABLE NEUROANATOMY
    CHRISTENSEN, GE
    RABBITT, RD
    MILLER, MI
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 609 - 618
  • [7] AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE
    COLLINS, DL
    NEELIN, P
    PETERS, TM
    EVANS, AC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 192 - 205
  • [8] COLLINS DL, 1992, P SOC PHOTO-OPT INS, V1808, P10, DOI 10.1117/12.131063
  • [9] Automatic 3D segmentation of internal structures of the head in MR images using a combination of similarity and free form transformations.
    Dawant, BM
    Thirion, JP
    Maes, F
    Vandermeulen, D
    Demaerel, P
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 545 - 554
  • [10] ELASTICALLY DEFORMING 3D ATLAS TO MATCH ANATOMICAL BRAIN IMAGES
    GEE, JC
    REIVICH, M
    BAJCSY, R
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) : 225 - 236