Evaluation of medium voltage groundwall insulation exposed to high frequency pulse voltages

被引:3
|
作者
Ul Haq, S [1 ]
Jayaram, SH [1 ]
Cherney, EA [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
来源
PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE | 2005年
关键词
groundwall insulation; armour tape; fast rise time pulses; partial discharge; dissipation factor; adjustable speed drives;
D O I
10.1109/EEIC.2005.1566289
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Class-F 4.0 kV coils designed for medium voltage induction motors are aged under combined thermal and electrical stresses of 500h at a constant temperature of 120 degrees C and 200h at a constant temperature of 150 degrees C and stressed electrically at 60 Hz and with steep-front unipolar pulses of 40 ns rise time. The changes in the partial discharge activity and the dissipation factor as a function of time are reported. During ageing, the temperature profiles are recorded with an infrared camera as a means for determining the highest stressed regions. The experimental results show that pulse ageing is very severe when compared to 60 Hz ageing, despite using a lower pulse voltage, although the location where damage occurs on the groundwall insulation is different.
引用
收藏
页码:194 / 197
页数:4
相关论文
共 50 条
  • [1] Evaluation of medium voltage stator bar groundwall insulation under inverter-fed pulses
    Haq, Saeed Ul
    Jayaram, Shesha H.
    Cherney, Edward A.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 465 - 468
  • [2] Aging characterization of medium voltage groundwall insulation intended for PWM applications
    Haq, Saeed Ul
    Jayaram, Shesha H.
    Cherney, Edward A.
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 143 - +
  • [3] Thermal conductivity of high voltage stator coil groundwall insulation
    Miller, ML
    Emery, FT
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 619 - 622
  • [4] Improved groundwall insulation for VPI'ed high voltage stator coils
    Emery, FT
    Smith, JDB
    Schoch, KF
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 589 - 592
  • [5] Endurance of polymeric insulation foil exposed to DC-biased medium-frequency rectangular pulse voltage stress
    Färber R.
    Guillod T.
    Krismer F.
    Kolar J.W.
    Franck C.M.
    Energies, 2019, 1
  • [6] Endurance of Polymeric Insulation Foil Exposed to DC-Biased Medium-Frequency Rectangular Pulse Voltage Stress
    Faerber, Raphael
    Guillod, Thomas
    Krismer, Florian
    Kolar, Johann W.
    Franck, Christian M.
    ENERGIES, 2020, 13 (01)
  • [7] Development of a Test Bench for the Investigation of the Breakdown Voltage of Insulation Materials at Medium Frequency Rectangular Voltages
    Moller, Robert
    Vocke, Jan
    Muhlbeier, Artur
    Puffer, Ralf
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 2621 - 2628
  • [8] Effectiveness of stress grading coatings on form wound stator coil groundwall insulation under fast rise time pulse voltages
    Espino-Cortes, FP
    Cherney, EA
    Jayaram, S
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) : 844 - 851
  • [9] High-Voltage High-Frequency Testing for Medium-Voltage Motor Insulation Degradation
    Mirza, Arshiah
    Chen, Weiqiang
    Hiep Nguyen
    Cao, Yang
    Bazzi, Ali M.
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 2444 - 2447
  • [10] Analysis of Thermal Stresses in Medium-voltage Motor Coils under Repetitive Fast Pulse and High-frequency Voltages
    Sharifi, Emad
    Jayaram, Shesha H.
    Cherney, Edward A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1378 - 1384