Individualized Estimation of the Central Aortic Blood Pressure Waveform: A Comparative Study

被引:15
作者
Hahn, Jin-Oh [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Central aortic blood pressure; generalized transfer function; individualized transfer function; VALIDATION; DERIVATION; PULSE;
D O I
10.1109/JBHI.2013.2262945
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a comparative study on the relative performance of alternative strategies for estimating an individualized central aortic blood pressure (BP) waveform. Based on the transmission line representation of the central aortic-radial arterial line, a fully individualized (ITF1), two partially individualized (ITF2 and ITF3), and a fully nonindividualized (NITF) transfer functions (i.e., frequency-dependent central aortic-radial BP relationships) were constructed using experimental data collected from nine swine subjects. The central aortic BP waveforms estimated by these transfer functions were compared against their measured gold standards, with the root-mean-squared waveform error and the absolute errors associated with systolic and pulse pressures as performance measures. Overall, the advantage of the individualized over the nonindividualized approach was modest but significant. The superiority of the individualized approach to its nonindividualized counterpart was increasingly pronounced under nonnominal or extreme physiologic conditions, as the subject's pulse transit time deviated from the averaged nominal value. The results suggest that the use of a fully individualized transfer function (ITF1) is strongly recommended for nonnominal physiologic conditions, whereas a partially (ITF2 and ITF3) or even fully nonindividualized transfer function (NITF) may also yield acceptable performance under nominal physiologic conditions.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 21 条
[1]   Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry [J].
Fetics, B ;
Nevo, E ;
Chen, CH ;
Kass, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :698-706
[2]  
Franklin G., 1998, Digital Control of Dynamic Systems, V3
[3]   Validation of the transfer function technique for generating central from peripheral upper limb pressure waveform [J].
Gallagher, D ;
Adji, A ;
O'Rourke, MF .
AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (11) :1059-1067
[4]  
Hahn J. O., 2008, THESIS MIT CAMBRIDGE
[5]   Subject-Specific Estimation of Central Aortic Blood Pressure Using an Individualized Transfer Function: A Preliminary Feasibility Study [J].
Hahn, Jin-Oh ;
Reisner, Andrew T. ;
Jaffer, Farouc A. ;
Asada, H. Harry .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (02) :212-220
[6]   Estimation of pulse transit time using two diametric blood pressure waveform measurements [J].
Hahn, Jin-Oh ;
Reisner, Andrew T. ;
Asada, H. Harry .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) :753-759
[7]   Blind Identification of Two-Channel IIR Systems With Application to Central Cardiovascular Monitoring [J].
Hahn, Jin-Oh ;
Reisner, Andrew T. ;
Asada, H. Harry .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2009, 131 (05) :1-15
[8]   Use of arterial transfer functions for the derivation of aortic waveform characteristics [J].
Hope, SA ;
Tay, DB ;
Meredith, IT ;
Cameron, JD .
JOURNAL OF HYPERTENSION, 2003, 21 (07) :1299-1305
[9]   A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients [J].
Jansen, JRC ;
Schreuder, JJ ;
Mulier, JP ;
Smith, NT ;
Settels, JJ ;
Wesseling, KH .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) :212-222
[10]   COMPARISON OF SIMULTANEOUSLY RECORDED CENTRAL AND PERIPHERAL ARTERIAL PRESSURE PULSES DURING REST, EXERCISE AND TILTED POSITION IN MAN [J].
KROEKER, EJ ;
WOOD, EH .
CIRCULATION RESEARCH, 1955, 3 (06) :623-632