Novel Square-Wave Signal Injection Method Using Zero-Sequence Voltage for Sensorless Control of PMSM Drives

被引:87
作者
Xu, P. L. [1 ]
Zhu, Z. Q. [1 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
Permanent-magnet synchronous machines (PMSMs); sensorless control; square-wave injection; zero-sequence voltage; ROTOR POSITION ESTIMATION; SELF-SENSING EVALUATION; AC MACHINES; CROSS-SATURATION; INDUCTION; MOTOR; RELUCTANCE; BANDWIDTH; OBSERVER; SALIENCY;
D O I
10.1109/TIE.2016.2593657
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a novel square-wave-type carrier signal injection method using zero-sequence voltage is proposed for sensorless control of permanent-magnet (PM) synchronous machine drives. Different from the conventional square-wave-type injection methods employed in the stationary reference frame and estimated synchronous reference frame, the proposed square-wave injection is performed on the estimated reference frame, which rotates anticlockwise at twice estimated rotor electrical angular speed. Compared to the conventional square-wave methods with carrier current sensing, the proposed strategy using zero-sequence voltage has two main advantages, 1) the amplitude of the resultant carrier response is not related to the injection frequency, and 2) the carrier response does not require differentiation calculation for rotor position estimation. Therefore, the proposed method is more robust and also much simpler for signal demodulation, which can combine the synergies of zero-sequence method and squarewave injection (i.e., increased accuracy, bandwidths, and stability, etc.). Finally, all the theoretical analyses are validated by experiments on a laboratory PM machine.
引用
收藏
页码:7444 / 7454
页数:11
相关论文
共 37 条
  • [1] Convergence Analysis of Extended Kalman Filter for Sensorless Control of Induction Motor
    Alonge, Francesco
    Cangemi, Tommaso
    D'Ippolito, Filippo
    Fagiolini, Adriano
    Sferlazza, Antonino
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (04) : 2341 - 2352
  • [2] Rotor position estimation of AC machines using the zero-sequence carrier-signal voltage
    Briz, F
    Degner, MW
    García, P
    Guerrero, JM
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (06) : 1637 - 1646
  • [3] Briz F, 2004, IEEE T IND APPL, V40, P1107, DOI [10.1109/TIA.2004.830768, 10.1109/tia.2004.830768]
  • [4] Briz F, 2001, IEEE IND APPLIC SOC, P2645, DOI 10.1109/IAS.2001.955992
  • [5] Harmonic analysis of voltage zero-sequence-based encoderless techniques
    Consoli, Alfio
    Scarcella, Giuseppe
    Bottiglieri, Giovanni
    Testa, Antonio
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (06) : 1548 - 1557
  • [6] Anisotropy Comparison of Reluctance and PM Synchronous Machines for Position Sensorless Control Using HF Carrier Injection
    De Kock, Hugo W.
    Kamper, Maarten J.
    Kennel, Ralph M.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) : 1905 - 1913
  • [7] Accuracy, bandwidth, and stability limits of carrier-signal-injection-based sensorless control methods
    Garcia, Pablo
    Briz, Fernando
    Degner, Michael W.
    Diaz-Reigosa, David
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (04) : 990 - 1000
  • [8] Robust Initial Rotor Position Estimation of Permanent-Magnet Brushless AC Machines With Carrier-Signal-Injection-Based Sensorless Control
    Gong, L. M.
    Zhu, Z. Q.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (06) : 2602 - 2609
  • [9] Impact of cross-saturation in sensorless control of transverse-laminated synchronous reluctance motors
    Guglielmi, P
    Pastorelli, M
    Vagati, A
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (02) : 429 - 439
  • [10] Hammel Wolfgang, 2010, 2010 First Symposium on Sensorless Control for Electrical Drives (SLED 2010), P56, DOI 10.1109/SLED.2010.5542801