Dual-source parallel RF transmission for diffusion-weighted imaging of the abdomen using different b values: Image quality and apparent diffusion coefficient comparison with conventional single-source transmission

被引:10
作者
Guo, Lijun [1 ]
Liu, Cheng [1 ]
Chen, Weibo [2 ,3 ]
Chan, Queenie
Wang, Guangbin [1 ]
机构
[1] Shandong Univ, Shandong Med Imaging Res Inst, Jinan 250100, Peoples R China
[2] Philips Healthcare, Shanghai, Peoples R China
[3] Philips Healthcare, Hong Kong, Hong Kong, Peoples R China
关键词
diffusion-weighted imaging; image quality; apparent diffusion coefficient; dual-source parallel radiofrequency transmission; single-source radiofrequency transmission; b values; HEPATOCELLULAR-CARCINOMA; LIVER-LESIONS; 1.5; T; MRI; EXCITATION; EXPERIENCE; BREATHHOLD; SPLEEN; BODY;
D O I
10.1002/jmri.23869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively and intraindividually evaluate what effects dual-source parallel radiofrequency (RF) transmission have on image quality and apparent diffusion coefficient (ADC) of abdomen diffusion-weighted imaging (DWI) using different b values, compared with the single-source RF transmission. Materials and Methods: Eighteen healthy male volunteers were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant Institutional Review Board (IRB)-approved study. Abdominal DWI was performed with dual-source and single-source RF transmission at 3.0 T using a series of b-value combinations: 0/100, 0/500, 0/800, and 0/100/800. RF field homogeneity, subjective image quality, and signal to noise ratio (SNR) of each abdominal organ were evaluated. ADC values were calculated for each abdominal organ. Wilcoxon test and repeated-measures analysis of variance was used to calculate statistical significance. Results: The parallel RF transmission significantly improved homogeneity of the RF field (P = 0.00010.008) and subjective image quality (P < 0.0001) at each b value and also increased SNR. At lower and higher b value, the measured ADC of lateral left hepatic lobe and spleen between dual-source and single-source images were significantly different (P = 0.00010.047). At b = 0/500, there was no significant difference in ADC measurements between dual-source and single-source RF transmission for abdominal organs, except a slight statistically significant difference for spleen (P = 0.047). Conclusion: Parallel RF transmission significantly improved the image quality and homogeneity of the RF field. The RF transmission had a significant influence on measured ADC of lateral left hepatic lobe and spleen. At b = 0/500 the influence was minimum for all abdominal organs. J. Magn. Reson. Imaging 2013;37:875885. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:875 / 885
页数:11
相关论文
共 34 条
[1]   Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values [J].
Bilgili, Mirace Yasemin Karadeniz .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) :2066-2068
[2]   Superparamagnetic iron oxide-enhanced liver magnetic resonance imaging - Comparison of 1.5 T and 3.0 T imaging for detection of focal malignant liver lesions [J].
Chang, JM ;
Lee, JM ;
Lee, MW ;
Choi, JY ;
Kim, SH ;
Lee, JY ;
Han, JK ;
Choi, BI .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :168-174
[3]   3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T [J].
Chang, Kevin J. ;
Kamel, Ihab R. ;
Macura, Katarzyna J. ;
Bluemke, David A. .
RADIOGRAPHICS, 2008, 28 (07) :1983-1998
[4]   Early response of hepatocellular carcinoma to transcatheter arterial chemoembolization: Choline levels and MR diffusion constants initial experience [J].
Chen, CY ;
Li, CW ;
Kuo, YT ;
Jaw, TS ;
Wu, DK ;
Jao, JC ;
Hsu, JS ;
Liu, GC .
RADIOLOGY, 2006, 239 (02) :448-456
[5]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[6]   Field Strength and Diffusion Encoding Technique Affect the Apparent Diffusion Coefficient Measurements in Diffusion-Weighted Imaging of the Abdomen [J].
Dale, Brian M. ;
Braithwaite, Adam C. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (02) :104-108
[7]  
Dietrich O, 2001, MAGNET RESON MED, V45, P448, DOI 10.1002/1522-2594(200103)45:3<448::AID-MRM1059>3.0.CO
[8]  
2-W
[9]   Diagnosis of Liver Fibrosis and Cirrhosis With Diffusion-Weighted Imaging: Value of Normalized Apparent Diffusion Coefficient Using the Spleen as Reference Organ [J].
Do, Richard K. G. ;
Chandanara, Hersh ;
Felker, Ely ;
Hajdu, Cristina H. ;
Babb, James S. ;
Kim, Danny ;
Taouli, Bachir .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :671-676
[10]   Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion [J].
Franklin, Kendra M. ;
Dale, Brian M. ;
Merkle, Elmar M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1443-1447