Online trapping and enrichment ultra performance liquid chromatography-tandem mass spectrometry method for sensitive measurement of "arginine-asymmetric dimethylarginine cycle" biomarkers in human exhaled breath condensate

被引:18
作者
Di Gangi, Iole Maria [1 ]
Pirillo, Paola [1 ]
Carraro, Silvia [2 ]
Gucciardi, Antonina [1 ]
Naturale, Mauro [1 ]
Baraldi, Eugenio [2 ]
Giordano, Giuseppe [1 ]
机构
[1] Univ Padua, Dept Womens & Childrens Hlth, Chromatog & Mass Spectrometry Lab, I-35128 Padua, Italy
[2] Univ Padua, Dept Womens & Childrens Hlth, Unit Allergy & Resp Dis, I-35128 Padua, Italy
关键词
ADMA; NOS; Arginine-ADMA cycle; Exhaled breath condensate (EBC); Tandem mass spectrometry; NITRIC-OXIDE; HUMAN PLASMA; SYMMETRIC DIMETHYLARGININE; SYNTHASE INHIBITOR; BIOLOGICAL SAMPLES; LUNG INFLAMMATION; OXIDATIVE STRESS; ASTHMA; ADMA; N-G; N-G-DIMETHYL-L-ARGININE;
D O I
10.1016/j.aca.2012.09.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Exhaled breath condensate (EBC) is a biofluid collected non invasively that, enabling the measurement of several biomarkers, has proven useful in the study of airway inflammatory diseases, including asthma, COPD and cystic fibrosis. To the best of our knowledge, there is no previous report of any analytical method to detect ADMA in EBC. Objectives: Aim of this work was to develop an online sample trapping and enrichment system, coupled with an UPLC-MS/MS method, for simultaneous quantification of seven metabolites related to "Arginine-ADMA cycle", using the isotopic dilution. Methods: Butylated EBC samples were trapped in an online cartridge, washed before and after each injection with cleanup solution to remove matrix components and switched inline into the high pressure analytical column. Multiple reaction monitoring in positive mode was used for analyte quantification by tandem mass spectrometry. Results: Validation studies were performed in EBC to examine accuracy, precision and robustness of the method. For each compound, the calibration curves showed a coefficient of correlation (r(2)) greater than 0.992. Accuracy (%Bias) was <3% except for NMMA and H-Arg (<20%), intra- and inter-assay precision (expressed as CV%) were within +/-20% and recovery ranged from 97.1 to 102.8% for all analytes. Inter-day variability analysis on 20 EBC of adult subjects did not demonstrate any significant variation of quantitative data for each metabolite. ADMA and SDMA mean concentrations (mu mol L-1), measured in EBC samples of asthmatic adolescents are significantly increased (p < 0.0001) than in normal controls (0.0040 +/- 0.0021 vs. 0.0012 +/- 0.0005 and 0.0020 +/- 0.0015 vs. 0.0002 +/- 0.0001, respectively), as well the ADMA/Tyr (0.34 +/- 0.09 vs. 0.12 +/- 0.02, p < 0.0001) and the SDMA/Tyr ratio (0.10 +/- 0.04 vs. 0.015 +/- 0.004, p < 0.0001). Conclusions: The proposed method features simple specimen preparation, maintenance of an excellent peak shape of all metabolites and reduced matrix effects as well mass spectrometer noise. Moreover, the possibility to perform different cycles of enrichment, using large injection volumes, compensated for the low concentration of analytes contained in EBC, leading to a good analytical sensitivity. Preliminary data obtained from asthmatic and healthy adolescents, demonstrated that the analytical method applied to EBC seems suitable not only for research purposes, but also for clinical routinely analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 44 条
[1]   Determination of NG,NG-dimethyl-L-arginine, an endogenous NO synthase inhibitor, by gas chromatography-mass spectrometry [J].
Albsmeier, J ;
Schwedhelm, E ;
Schulze, F ;
Kastner, M ;
Böger, RH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01) :59-65
[2]   Nitric oxide synthases: structure, function and inhibition [J].
Alderton, WK ;
Cooper, CE ;
Knowles, RG .
BIOCHEMICAL JOURNAL, 2001, 357 (03) :593-615
[3]   Stable isotope dilution assay for liquid chromatography-tandem mass spectrometric determination of L-homoarginine in human plasma [J].
Atzler, Dorothee ;
Mieth, Maren ;
Maas, Renke ;
Boeger, Rainer H. ;
Schwedhelm, Edzard .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23) :2294-2298
[4]   Direct analysis of un-derivatized asymmetric dimethylarginine (ADMA) and L-arginine from plasma using mixed-mode ion-exchange liquid chromatography-tandem mass spectrometry [J].
Bishop, Michael J. ;
Crow, Brian ;
Norton, Dean ;
Paliakov, Ekaterina ;
George, Joe ;
Bralley, J. A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (02) :164-169
[5]   The biochemistry, measurement and current clinical significance of asymmetric dimethylarginine [J].
Blackwell, Scott .
ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 :17-28
[6]   INDUCTION OF N-G-MONOMETHYL-L-ARGININE UPTAKE - A MECHANISM FOR DIFFERENTIAL INHIBITION OF NO SYNTHASES [J].
BOGLE, RG ;
MACALLISTER, RJ ;
WHITLEY, GS ;
VALLANCE, P .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1995, 269 (03) :C750-C756
[7]   Analysis of methylarginine metabolism in the cardiovascular system identifies the lung as a major source of ADMA [J].
Bulau, Patrick ;
Zakrzewicz, Dariusz ;
Kitowska, Kamila ;
Leiper, James ;
Gunther, Andreas ;
Grimminger, Friedrich ;
Eickelberg, Oliver .
AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2007, 292 (01) :L18-L24
[8]   Determination of asymmetrical dimethylarginine by capillary electrophoresis-laser-induced fluorescence [J].
Caussé, E ;
Siri, N ;
Arnal, JF ;
Bayle, C ;
Malatray, P ;
Valdiguié, P ;
Salvayre, R ;
Couderc, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 741 (01) :77-83
[9]   Simultaneous determination of 3-nitrotyrosine, tyrosine, hydroxyproline and proline in exhaled breath condensate by hydrophilic interaction liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Conventz, A. ;
Musiol, A. ;
Brodowsky, C. ;
Mueller-Lux, A. ;
Dewes, P. ;
Kraus, T. ;
Schettgen, T. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (01) :78-85
[10]   Development and validation of a fast quantitative method for plasma dimethylarginines analysis using liquid chromatography-tandem mass spectrometry [J].
D'Apolito, Oceania ;
Paglia, Giuseppe ;
Tricarico, Filomena ;
Garofalo, Daniela ;
Pilotti, Alessandra ;
Lamacchia, Olga ;
Cignarelli, Mauro ;
Corso, Gaetano .
CLINICAL BIOCHEMISTRY, 2008, 41 (16-17) :1391-1395