ELECTROMAGNETIC AND HYDRODYNAMIC CHARACTERISTICS OF THE EXTRACORPOREAL MAGNETIC DRIVING SYSTEM FOR AN AXIAL FLOW BLOOD PUMP

被引:0
作者
Tan Wei [1 ]
Tan Jianping [1 ]
Liu Yunlong [1 ]
Tan Zhuo [1 ]
机构
[1] Cent S Univ, Sch Mech & Elect Engn, Changsha 410083, Peoples R China
来源
MAGNETOHYDRODYNAMICS | 2012年 / 48卷 / 03期
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
DRIVEN; DESIGN; FIELD; FLUX;
D O I
暂无
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Extracorporeal magnetic driving approach is a potential alternative to replace conventional intra-driving methods for the axial flow blood pump, which can minimize external infection brought by through-skin wires and simplify the internal structure. The investigation has been undertaken to study electromagnetic and hydrodynamic characteristics of four novel large gap extracorporeal in magnetic driving systems varying in connection of structure, inclination angular and magnet pole number. Using finite element analysis based simulation and empirical verification, comparison upon performance of four different extracorporeal magnetic schemes was conducted. Using ANSYS, numerical solutions have been obtained consisting of vector plots of 3D magnetic field density and flux plots of 2D mean torque data. W-shape as a preferred scheme has 71.52% and 148.32% increments of the magnetic field density and mean torque on the axial flow blood pump, respectively, over D-T-shape. Experiment has verified the simulation results by direct measurement of magnetic field density, flow rate and pressure head, which has the magnetic field density and torque increased by 38.70% and 145.56%, respectively. Both simulation and experiment indicate that the addition of connection, inclination and magnet pole number would boost the performance; thus, the W-shape is the preferred system.
引用
收藏
页码:543 / 556
页数:14
相关论文
共 21 条
[1]  
Bucenieks I, 2011, MAGNETOHYDRODYNAMICS, V47, P97
[2]   Miniaturization of a Magnetically Levitated Axial Flow Blood Pump [J].
Cheng, Shanbao ;
Olles, Mark W. ;
Olsen, Don B. ;
Joyce, Lyle D. ;
Day, Steven W. .
ARTIFICIAL ORGANS, 2010, 34 (10) :807-815
[3]   Effect of Variation of B-H Properties on Loss and Flux Inside Silicon Steel Lamination [J].
Cheng, Z. ;
Takahashi, N. ;
Forghani, B. ;
Du, Y. ;
Fan, Y. ;
Liu, L. ;
Zhao, Z. ;
Wang, H. .
IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (05) :1346-1349
[4]   Numerical simulation of an axial blood pump [J].
Chua, Leok Poh ;
Su, Boyang ;
Lim, Tau Meng ;
Zhou, Tongming .
ARTIFICIAL ORGANS, 2007, 31 (07) :560-570
[5]   Systemic consequences of ventricular assist devices: Alterations of coagulation, immune function, inflammation, and the neuroendocrine system [J].
Hampton, CR ;
Verrier, ED .
ARTIFICIAL ORGANS, 2002, 26 (11) :902-908
[6]   Magnetic Drive System for a New Centrifugal Rotary Blood Pump [J].
Hilton, Andrew ;
Tansley, Geoff .
ARTIFICIAL ORGANS, 2008, 32 (10) :772-777
[7]   Third-generation blood pumps with mechanical noncontact magnetic bearings [J].
Hoshi, H ;
Shinshi, T ;
Takatani, S .
ARTIFICIAL ORGANS, 2006, 30 (05) :324-338
[8]   Determination of the carrier frequencies of selected GJB2 mutations in the Korean population [J].
Kim, Shin Young ;
Lee, Bom Yi ;
Lim, Ji Hyae ;
Ryu, Hyun Mee ;
Yang, Jae Hyug ;
Chung, Jin Hoon ;
Han, Ho Won ;
Park, So Yeon .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (10) :694-698
[9]   Preliminary in vivo study of an intra-aortic impeller pump driven by an extracorporeal whirling magnet [J].
Li, GR ;
Zhao, H ;
Zhu, XD ;
Ren, B .
ARTIFICIAL ORGANS, 2002, 26 (10) :890-893
[10]  
[刘志坚 Liu Zhijian], 2010, [机械设计, Journal of Machine Design], V27, P56