Correlating the characteristics of the CN tower lightning return-stroke current with those of its generated electromagnetic pulse

被引:22
作者
Hussein, Ali M. [1 ,2 ]
Milewski, Mariusz [1 ]
Janischewskyj, Wasyl [2 ]
机构
[1] Ryerson Univ, Elect & Comp Engn Dept, Toronto, ON M5B 2K3, Canada
[2] Univ Toronto, Elect & Comp Engn Dept, Toronto, ON M5S 3G4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
lightning detection; lightning electromagnetic pulse (LEMP); return-stroke current; tall-structure lightning;
D O I
10.1109/TEMC.2008.924398
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Simultaneous measurements of the lightning return-stroke current derivative at the Canadian National (CN) Tower and the corresponding lightning electromagnetic pulse (LEMP) 2 km north of the tower have been performed since 1991 using broadband, high-resolution measurement systems. The recent installation of global positioning systems for time synchronization of CN Tower lightning measurement stations has enabled the correlation of the wavefront characteristics (peak, maximum derivative, and 10-90% rise time) of the return-stroke current with those of its LEMP. The characteristics of the tower's lightning electric and magnetic fields have also been correlated with each other. The current and field correlation analysis is based on August 19, 2005, CN Tower lightning return-stroke data. In addition to the strong linear correlations of the wavefront characteristics of the electric and magnetic field waveforms, an excellent linear correlation has been established between the magnetic field and current wavefront peaks. Also, a good linear correlation has been found between the magnetic field wavefront maximum derivative and that of the current. These findings are of interest in lightning detection methodology. For example, the current wavefront maximum derivative can be estimated from the detected magnetic field after taking into consideration the propagation effect on its derivative. Although weakly correlated, a general trend of increase in the magnetic field peak and maximum rate of rise has been observed as the current maximum rate of rise and peak increase, respectively. It is hoped that the field-current relationships developed in this paper, using the recent CN Tower lightning return-stroke data, will contribute to solving the inverse-source problem, one of the challenging problems in lightning research, where lightning current characteristics are estimated based on the characteristics of the measured LEMP.
引用
收藏
页码:642 / 650
页数:9
相关论文
共 23 条
[1]   On the use of lumped sources in lightning return stroke models [J].
Baba, Y ;
Rakov, VA .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2005, 110 (D3) :1-10
[2]   Lightning electromagnetic environment in the presence of a tall grounded strike object [J].
Baba, Y ;
Rakov, VA .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2005, 110 (D9) :1-18
[3]   Electromagnetic fields at the top of a tall building associated with nearby lightning return strokes [J].
Baba, Yoshihiro ;
Rakov, Vladimir A. .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2007, 49 (03) :632-643
[4]   Determination of lightning currents from far electromagnetic fields: Effect of a strike object [J].
Bermudez, J. L. ;
Rachidi, F. ;
Janischewskyj, W. ;
Shostak, V. ;
Rubinstein, M. ;
Pavanello, D. ;
Hussein, A. M. ;
Chang, J. S. ;
Paolone, M. .
JOURNAL OF ELECTROSTATICS, 2007, 65 (5-6) :289-295
[5]  
Bitner K., 2006, P 28 INT C LIGHTN PR, P261
[6]   Lightning current and magnetic field parameters caused by lightning strikes to tall structures relating to interference of electronic systems [J].
Fuchs, F ;
Landers, EU ;
Schmid, R ;
Wiesinger, J .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1998, 40 (04) :444-451
[7]  
HEIDLER F, 2001, 14 INT S TECH EXH EL
[8]   Characteristics of lightning flashes striking the CN Tower below its tip [J].
Hussein, A. M. ;
Milewski, M. ;
Janischewskyj, W. ;
Noor, F. ;
Jabbar, F. .
JOURNAL OF ELECTROSTATICS, 2007, 65 (5-6) :307-315
[9]  
Hussein A.M., 2006, P 28 INT C LIGHTN PR, P89
[10]  
Hussein A. M., 2006, P 18 INT WROCL S EXH, P296