An experimental study on the dehumidification performance of a low-flow falling-film liquid desiccant air-conditioner

被引:15
|
作者
Bouzenada, S. [1 ]
McNevin, C. [2 ]
Harrison, S. [2 ]
Kaabi, A. N. [1 ]
机构
[1] Univ 3 Constantine, Dept Architecture, Lab Energy & Environm, Ali Mendjeli 25000, Algeria
[2] Queens Univ, Dept Mech & Mat Engn, Solar Calorimetry Lab, Kingston, ON, Canada
来源
6TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2015), THE 5TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2015) | 2015年 / 52卷
关键词
liquid desiccant; air-conditioning; dehumidification effectiveness; lithium chloride; falling film; low flow; HVAC;
D O I
10.1016/j.procs.2015.05.135
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The dehumidifier is one of the main components in open-cycle liquid desiccant air-conditioning systems. An experimental study was carried out to evaluate the performance of a solar thermally driven, low-flow, falling-film, internally-cooled parallelplate liquid desiccant air-conditioner in Kingston, Ontario at Queen's University. A solution of LiC1 and water was used as the desiccant. Unlike high-flow devices, the low-flow of desiccant solution flowing across the unit's dehumidifier and regenerator sections produces large variations in solution concentration. In this study, a series of tests were undertaken to evaluate the performance of the dehumidifier section of the unit. Results presented are based on mass flow and energy transport measurements that allowed the moisture transport rate between the air and liquid desiccant solution to be determined. Based on these results, a relationship between the desiccant concentration and the rate of dehumidification rate was found and the effect of inlet-air humidity on the dehumidification effectiveness identified. The moisture removal rate of the system was found to range from 1.1 g/s to 3.5 g/s under the conditions evaluated. These result corresponded to an average dehumidification effectiveness of 0.55. (C) 2015 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creavativecommons.org/licesses/by-nc-nd/4.0/). Peer-review under responsibility of the Conference Program Chairs
引用
收藏
页码:796 / 803
页数:8
相关论文
共 50 条
  • [1] Falling film liquid desiccant air dehumidification
    Dong, Chuanshuai
    Hibiki, Takashi
    Zhang, Lizhi
    Lu, Lin
    EXPERIMENTAL AND COMPUTATIONAL MULTIPHASE FLOW, 2020, 2 (04) : 187 - 198
  • [2] Falling film liquid desiccant air dehumidification
    Chuanshuai Dong
    Takashi Hibiki
    Lizhi Zhang
    Lin Lu
    Experimental and Computational Multiphase Flow, 2020, 2 : 187 - 198
  • [3] Experimental investigation and model validation for liquid desiccant dehumidification and regeneration in falling-film plate
    Qian, Junfei
    Yin, Yonggao
    Pan, Xiongwei
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2014, 65 (06): : 2070 - 2077
  • [4] Correlation of dehumidification by a falling film desiccant with air in cross flow
    Park, MoonSoo
    Howell, John R.
    Vliet, Gary C.
    Winter Annual Meeting of the American Society of Mechanical Engineers, 1994, : 1 - 9
  • [5] Performance characterisation of liquid desiccant columns for a hybrid air-conditioner
    Mohan, B. Shaji
    Maiya, M. Prakash
    Tiwari, Shaligram
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1342 - 1355
  • [6] Analysis of a cross-flow liquid-desiccant falling-film
    Emhofer, J.
    Beladi, B.
    Dudzinski, P.
    Fleck, T.
    Kuhlmann, H. C.
    APPLIED THERMAL ENGINEERING, 2017, 124 : 91 - 102
  • [7] Multi-stage liquid-desiccant air-conditioner: Experimental performance and model development
    McNevin, Christopher
    Harrison, Stephen J.
    BUILDING AND ENVIRONMENT, 2017, 114 : 45 - 55
  • [8] Experimental analysis on dehumidification performance of an indoor passive falling film liquid desiccant moisture receptacle
    Chen Jianbo
    Xue Xue
    Qu Minglu
    Han Xing
    Kang Youli
    ENERGY AND BUILDINGS, 2016, 125 : 161 - 170
  • [9] An experimental study on the dehumidification performance of a counter flow liquid desiccant dehumidifier
    Wang, Lingshi
    Xiao, Fu
    Zhang, Xuejun
    Kumar, Ritunesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 289 - 301
  • [10] Experimental study of the flow characteristics in a falling film liquid desiccant dehumidifier
    Luo, Yimo
    Chen, Yi
    Zhong, Dan
    Wang, Yuanhao
    Yang, Hongxing
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 157 - 165