A method for the geometric standardization of intraoral radiographs for long-term follow up of replanted teeth: a case report

被引:5
作者
Hamanaka, Elizane Ferreira [1 ]
Poi, Wilson Roberto [1 ]
Pescinini Salzedas, Leda Maria [1 ]
Alves, Lucieni Campoli [1 ]
Panzarini, Sonia Regina [1 ]
Sonoda, Celso Koogi [1 ]
Martins, Christine Men [1 ]
机构
[1] Sao Paulo State Univ UNESP, Dept Surg & Integrated Clin, Sch Dent Aracatuba, Aracatuba, SP, Brazil
关键词
radiographic standardization; dentoalveolar trauma; tooth avulsion; tooth replantation; TRAUMATIC DENTAL INJURIES; SUBTRACTION; GUIDELINES; MANAGEMENT; ALIGNMENT; ACCURACY; IMAGES;
D O I
10.1111/j.1600-9657.2012.01145.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4h in saline storage. Endodontic treatment started 7days after the trauma with changes of a calcium hydroxide intracanal medication every 15days in the first 2months and thereafter at 30-day intervals for 8months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10months after replantation up to 76months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 33 条
[1]   An ex vivo comparison of conventional and digital radiography for perceived image quality of root fillings [J].
Akdeniz, BG ;
Sogur, E .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (06) :397-401
[2]  
ANDREASEN FM, 1988, ENDOD DENT TRAUMATOL, V4, P170
[3]  
[Anonymous], 2007, TXB COLOR ATLAS TRAU
[4]  
Bridgman JB, 1995, NZ DENT J, V91, P6
[5]  
Caldeira EJ, 2004, REV GAUCH ODONTOL, V2, P124
[6]   Clinical indications for digital imaging in dento-alveolar trauma. Part 1: traumatic injuries [J].
Cohenca, Nestor ;
Simon, James H. ;
Roges, Ramon ;
Morag, Yoav ;
Malfaz, Jose Maria .
DENTAL TRAUMATOLOGY, 2007, 23 (02) :95-104
[7]   Oral cancer staging established by magnetic resonance imaging [J].
de Paiva, Rogerio Ribeiro ;
de Souza Figueiredo, Paulo Tadeu ;
Leite, Andre Ferreira ;
Garcia Silva, Maria Alves ;
Silva Guerra, Eliete Neves .
BRAZILIAN ORAL RESEARCH, 2011, 25 (06) :512-518
[8]   An overview of radiographic film holders [J].
Dixon, DA ;
Hildebolt, CF .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (02) :67-73
[9]   Geometric alignment and chromatic calibration of serial radiographic images [J].
Dornier, C ;
Dorsaz-Brossa, L ;
Thévenaz, P ;
Casagni, F ;
Brochut, P ;
Mombelli, A ;
Vallée, J .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (04) :220-225
[10]  
Dove SB, 2000, ORAL SURG ORAL MED O, V89, P771