New redox and conducting polymer modified electrodes for cholesterol biosensing

被引:22
作者
Kakhki, Somayeh [1 ,2 ]
Barsan, Madalina M. [1 ]
Shams, Esmaeil [2 ]
Brett, Christopher M. A. [1 ]
机构
[1] Univ Coimbra, Dept Quim, Fac Ciencias & Tecnol, P-3004535 Coimbra, Portugal
[2] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
WALLED CARBON NANOTUBES; METHYLENE-BLUE; ELECTROCHEMICAL BIOSENSOR; GOLD NANOPARTICLES; COMPOSITE FILM; ASCORBIC-ACID; OXIDASE; PERFORMANCE; PLATINUM; IMMOBILIZATION;
D O I
10.1039/c3ay26409b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New enzyme biosensors for cholesterol detection based on a recently developed transduction platform constituted of a GCE modified with polymer redox mediator poly(methylene blue) (PMB) and conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) were for the first time prepared and evaluated. The enzyme cholesterol oxidase (ChOx) was immobilized by simple adsorption, the ChOx/PEDOT/PMB/GCE biosensor being applied for amperometric determination of cholesterol by monitoring the peroxide reduction produced by the enzymatic reaction at -0.4 V vs. SCE. Amperometric studies at fixed potential reveal that almost interference-free cholesterol determination can be achieved at the newly developed biosensor in a range between 10 and 220 mu M with a sensitivity of 79.0 mu A cm(-2) mM(-1) and a detection limit of 1.6 mu M. The recovery and storage stability of the biosensor were evaluated and the biosensor was applied to cholesterol detection in whole cow milk and chicken egg yolk.
引用
收藏
页码:1199 / 1204
页数:6
相关论文
共 51 条
[1]   High-performance electrochemical biosensor for the detection of total cholesterol [J].
Ahmadalinezhad, Asieh ;
Chen, Aicheng .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) :4508-4513
[2]   Cholesterol oxidase senses subtle changes in lipid bilayer structure [J].
Ahn, KW ;
Sampson, NS .
BIOCHEMISTRY, 2004, 43 (03) :827-836
[3]  
[Anonymous], 1987, ANALYST, V112, P199
[4]   Sensitive estimation of total cholesterol in blood using Au nanowires based micro-fluidic platform [J].
Aravamudhan, Shyam ;
Kumar, Arun ;
Mohapatra, Shyam ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2289-2294
[5]   Electrochemical biosensor for targeted detection in blood using aligned Au nanowires [J].
Aravamudhan, Shyarn ;
Ramgir, Niranjan S. ;
Bhansah, Shekhar .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :29-35
[6]   Simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid by methylene blue adsorbed on a phosphorylated zirconia-silica composite electrode [J].
Arguello, Jacqueline ;
Leidens, Victor L. ;
Magosso, Herica A. ;
Ramos, Rodrigo R. ;
Gushikem, Yoshitaka .
ELECTROCHIMICA ACTA, 2008, 54 (02) :560-565
[7]   Electrochemical study of methylene blue incorporated into mordenite type zeolite and its application for amperometric determination of ascorbic acid in real samples [J].
Arvand, M ;
Sohrabnezhad, S ;
Mousavi, MF ;
Shamsipur, M ;
Zanjanchi, MA .
ANALYTICA CHIMICA ACTA, 2003, 491 (02) :193-201
[8]   Biosensor for total cholesterol estimation using N-(2-aminoethyl)-3-aminopropyltrimethoxysilane self-assembled monolayer [J].
Arya, Sunil K. ;
Datta, Monika ;
Singh, S. P. ;
Malhotra, Bansi D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (7-8) :2235-2242
[9]  
Barhadillo M., 2009, TALANTA, V80, P797
[10]   Electrosynthesis and electrochemical characterisation of phenazine polymers for application in biosensors [J].
Barsan, Madalina M. ;
Pinto, Edilson M. ;
Brett, Christopher M. A. .
ELECTROCHIMICA ACTA, 2008, 53 (11) :3973-3982