Morphology optimization and assessment of the performance limits of high-porosity nanostructured polymer monolithic capillary columns for proteomics analysis

被引:21
作者
Dores-Sousa, Jose Luis [1 ]
Terryn, Herman [2 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel VUB, Dept Chem Engn, Brussels, Belgium
[2] Vrije Univ Brussel VUB, Dept Mat & Chem, Brussels, Belgium
关键词
Eddy dispersion; Separation impedance; Kinetic plot; UHPLC; Proteins; Peptides; Column technology; LARGE SURFACE-AREA; LIQUID-CHROMATOGRAPHY SEPARATIONS; HIGH-FLOW CHARACTERISTICS; PEAK-CAPACITY; EFFICIENT SEPARATION; KINETIC PERFORMANCE; ORGANIC MONOLITHS; MASS-SPECTROMETRY; STATIONARY PHASES; POROUS PROPERTIES;
D O I
10.1016/j.aca.2020.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study targets the synthesis of high external-porosity poly(styrene-co-divinylbenzene) monolithic support structures with macropore and globule sizes in the sub-micron range, aiming at the realization of high-speed and high-resolution gradient separations of intact proteins and peptides. The thermody-namic and kinetic aspects of the free-radical polymerization synthesis were adjusted by tuning the porogen to monomer ratio, the porogen ratio, the initiator content, and polymerization temperature. Next, column morphology was linked to eddy-dispersion and mobile-phase mass-transfer contributions and the chromatographic performance limits were benchmarked against conventional packed columns and silica monoliths. Polymer monolithic structures yielding a separation impedance as low as 976 were created allowing to generate N > 1,000,000 (for an unretained marker), albeit the expense of very long analysis times. Decreasing the macropore and globule sizes below a certain threshold led to significant increase in eddy dispersion, as globular entities agglomerate, and a small number of large flow-through pores permeate the overall fine interconnected polymer network with small diameter flow-through pores. The potential of monolith chromatography for proteomics application is demonstrated with a ballistic 6 s gradient separation of intact proteins and a high-resolution nanoLC-Orbitrap mass spec-trometric analysis of a tryptic E. coli digest applying a coupled-column system. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 183
页数:8
相关论文
共 46 条
[1]   Review of recent advances in the preparation of organic polymer monoliths for liquid chromatography of large molecules [J].
Arrua, R. Dario ;
Talebi, Mohammad ;
Causon, Tim J. ;
Hilder, Emily F. .
ANALYTICA CHIMICA ACTA, 2012, 738 :1-12
[2]   Understanding and design of existing and future chromatographic support formats [J].
Billen, J. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :73-99
[3]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[4]  
Broeckhoven K, 2018, LC GC N AM, V36, P9
[5]   Polymeric monolithic materials: Syntheses, properties, functionalization and applications [J].
Buchmeiser, Michael R. .
POLYMER, 2007, 48 (08) :2187-2198
[6]   Differences in porous characteristics of styrenic monoliths prepared by controlled thermal polymerization in molds of varying dimensions [J].
Bystrom, Emil ;
Viklund, Camilla ;
Irgum, Knut .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (02) :191-199
[7]   Detailed characterization of the kinetic performance of first and second generation silica monolithic columns for reversed-phase chromatography separations [J].
Cabooter, Deirdre ;
Broeckhoven, Ken ;
Sterken, Roman ;
Vanmessen, Alison ;
Vandendael, Isabelle ;
Nakanishi, Kazuki ;
Deridder, Sander ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1325 :72-82
[8]   Critical differences in chromatographic properties of silica- and polymer-based monoliths [J].
Causon, Tim J. ;
Nischang, Ivo .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1358 :165-171
[9]   A study of surface modification and anchoring techniques used in the preparation of monolithic microcolumns in fused silica capillaries [J].
Courtois, J ;
Szumski, M ;
Byström, E ;
Iwasiewicz, A ;
Shchukarev, A ;
Irgum, K .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) :14-24
[10]   FACTORS DETERMINING FLOW-RATE IN CHROMATOGRAPHIC COLUMNS [J].
CRAMERS, CA ;
RIJKS, JA ;
SCHUTJES, CPM .
CHROMATOGRAPHIA, 1981, 14 (07) :439-444