Bismuth-dispersed xerogel-based composite films for trace Pb(II) and Cd(II) voltammetric determination

被引:58
作者
Dimovasilis, Panagiotis A. [1 ]
Prodromidis, Mamas I. [1 ]
机构
[1] Univ Ioannina, Dept Chem, Analyt Chem Lab, GR-45110 Ioannina, Greece
关键词
Bismuth-modified xerogel; Bismuth precursors; Determination of Cd(II) and Pb(II) ions; Stripping voltammetry; SCREEN-PRINTED ELECTRODES; HEAVY-METAL IONS; STRIPPING VOLTAMMETRY; CARBON-PASTE; LEAD DETECTION; SENSORS; ACID; ELECTROANALYSIS; PRECURSOR; OXIDATION;
D O I
10.1016/j.aca.2013.01.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report for the first time the synthesis of bismuth-modified (3-mercaptopropyl) trimethoxysilane (MPTMS) and its application for the determination of lead and cadmium by anodic stripping voltammetry. Xerogels made from bismuth-modified MPTMS and mixtures of it with tetraethoxysilane, under basic conditions (NH3 center dot H2O), were characterized with scanning electron microscopy, energy dispersive spectroscopy, infrared spectroscopy and electrochemical methods. Bismuth-modified xerogels were mixed with 1.5% (v/v) Nafion in ethanol and applied on glassy carbon electrodes. During the electrolytic reductive deposition step, the bismuth compound on the electrode surface was reduced to metallic bismuth. The target metal cations were simultaneously reduced to the respective metals and were preconcentrated on the electrode surface by forming an alloy with bismuth. Then, an anodic voltammetric scan was applied in which the metals were oxidized and stripped back into the solution; the voltammogram was recorded and the stripping peak heights were related to the concentration of Cd(II) and Pb(II) ions in the sample. Various key parameters were investigated in detail and optimized. The effect of potential interferences was also examined. Under optimum conditions and for preconcentration period of 4 min, the 3 sigma limit of detection was 1.3 mu g L-1 for Pb(II) and 0.37 mu g L-1 for Cd(II), while the reproducibility of the method was 4.2% for lead (n=5, 10.36 mu g L-1 Pb(II)) and 3.9% for cadmium (n = 5, 5.62 mu g L-1 Cd(II)). Finally, the sensors were applied to the determination of Cd(II) and Pb(II) ions in water samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 39 条
  • [1] Morphology and Electrochemical Properties of the Bismuth Film Electrode Ex Situ Electrochemically Plated from Perchloric Acid
    Bobrowski, Andrzej
    Krolicka, Agnieszka
    Zarebski, Jerzy
    [J]. ELECTROANALYSIS, 2010, 22 (13) : 1421 - 1427
  • [2] Sensitive stripping voltammetry of heavy metals by using a composite sensor based on a built-in bismuth precursor
    Castañeda, MT
    Pérez, B
    Pumera, M
    del Valle, M
    Merkoçi, A
    Alegret, S
    [J]. ANALYST, 2005, 130 (06) : 971 - 976
  • [3] Characterization and Application of Bismuth-Film Modified Graphite-Polyurethane Composite Electrodes
    Cesarino, Ivana
    Gouveia-Caridade, Carla
    Pauliukaite, Rasa
    Cavalheiro, Eder T. G.
    Brett, Christopher M. A.
    [J]. ELECTROANALYSIS, 2010, 22 (13) : 1437 - 1445
  • [4] An electrochemical sensor for trace uranium determination based on 6-O-palmitoyl-L-ascorbic acid-modified graphite electrodes
    Dimovasilis, Panagiotis A.
    Prodromidis, Mamas I.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02) : 689 - 694
  • [5] Recent developments in the field of screen-printed electrodes and their related applications
    Dominguez Renedo, O.
    Alonso-Lomillo, M. A.
    Arcos Martinez, M. J.
    [J]. TALANTA, 2007, 73 (02) : 202 - 219
  • [6] Bismuth-film electrodes: recent developments and potentialities for electroanalysis
    Economou, A
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) : 334 - 340
  • [7] Synthesis and analytical potential of silica nanotubes
    Garcia-Calzon, J. A.
    Diaz-Garcia, M. E.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 35 : 27 - 38
  • [8] Influence of Nafion coatings and surfactant on the stripping voltammetry of heavy metals at bismuth-film modified carbon film electrodes
    Gouveia-Caridade, Carla
    Pauliukaite, Rasa
    Brett, Christopher M. A.
    [J]. ELECTROANALYSIS, 2006, 18 (09) : 854 - 861
  • [9] Peculiarities of Electrochemical Bismuth Film Formation in the Presence of Bromide and Heavy Metal Ions
    Grinciene, Giedre
    Selskiene, Ausra
    Verbickas, Rolandas
    Norkus, Eugenijus
    Pauliukaite, Rasa
    [J]. ELECTROANALYSIS, 2009, 21 (15) : 1743 - 1749
  • [10] An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmium
    Hwang, Gil-Ho
    Han, Won-Kyu
    Park, Joon-Shik
    Kang, Sung-Goon
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01): : 309 - 316