Quartz crystal microbalance humidity sensors integrated with hydrophilic polyethyleneimine-grafted polyacrylonitrile nanofibers

被引:59
|
作者
Rianjanu, Aditya [1 ,7 ]
Julian, Trisna [1 ,7 ]
Hidayat, Shidiq Nur [1 ,7 ]
Yulianto, Nursidik [2 ,3 ,4 ]
Majid, Nurhalis [4 ,5 ]
Syamsu, Iqbal [2 ,3 ,6 ]
Wasisto, Hutomo Suryo [2 ,3 ,7 ]
Triyana, Kuwat [1 ,7 ,8 ]
机构
[1] Univ Gadjah Mada, Fac Math & Nat Sci, Dept Phys, POB BLS 21, Yogyakarta 55281, Indonesia
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Semicond Technol IHT, Hans Sommer Str 66, D-38106 Braunschweig, Germany
[3] Tech Univ Carolo Wilhelmina Braunschweig, Lab Emerging Nanometrol LENA, Langer Kamp 6, D-38106 Braunschweig, Germany
[4] Indonesian Inst Sci LIPI, Res Ctr Phys, Jl Kawasan Puspiptek 441-442, Tangerang Selatan 15314, Indonesia
[5] Tech Univ Clausthal, Inst Energy Res & Phys Technol, Leibnizstr 4, D-38678 Clausthal Zellerfeld, Germany
[6] Indonesian Inst Sci LIPI, Res Ctr Elect & Telecommun, Jl Sangkuriang,Komplek LIPI Gedung 20, Bandung 40135, Indonesia
[7] PT NanoSense Instrument Indonesia, Umbulharjo 55167, Yogyakarta, Indonesia
[8] Univ Gadjah Mada, Inst Halal Ind & Syst IHIS, Sekip Utara 55281, Yogyakarta, Indonesia
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2020年 / 319卷
关键词
SENSING PROPERTIES; INFRARED-SPECTROSCOPY; PERFORMANCE; WATER; RESONATORS; MEMBRANES; POLYMERIZATION; FABRICATION; FILMS;
D O I
10.1016/j.snb.2020.128286
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we devised hybrid humidity sensors by integrating quartz crystal microbalance (QCM) platforms with polyethyleneimine (PEI)-grafted polyacrylonitrile (PAN) nanofibrous mats (i.e., PAN/PEI nanofibers) as active layers. The produced devices were characterized using a scanning electron microscope (SEM), an atomic force microscope (AFM), and a Fourier transform infrared (FTIR) spectrometer to investigate their morphologies, roughness, and molecular compositions, respectively. To understand the humidity sensing mechanism, an exponential kinetic model was developed for the adsorption and desorption processes of water molecules on nanofibers. The viscoelasticity of the active layer started to increase when the sensor was exposed to relative humidity (RH) of > 60 %rH. The PAN/PEI nanofiber-functionalized QCM sensors exhibited a sensitivity of up to 164 Hz/%rH with the response and recovery times of 13 and 7 s, respectively, during humidity exposure assessments performed at room temperature of (30 ± 1) °C. Moreover, they also provided high selectivity, long-term stability, and excellent repeatability with low error rates. Among the other existing QCM-based humidity sensors that were coated with various materials (e.g., metal oxides, carbon, and polymers), our unique electrospun PAN/PEI nanofibrous mat-functionalized QCM sensing devices have demonstrated the most superior performances in terms of their sensitivity and responsivity, which could then offer an alternative for high-sensing-performance yet low-cost humidity sensors. © 2020 Elsevier B.V.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Fabrication of quartz crystal microbalance humidity sensors based on super-hydrophilic cellulose nanocrystals
    Chen, Weixiang
    Chen, Bo
    Lv, Rixin
    Wu, Milian
    Zhou, Jie
    Lu, Beili
    Huang, Biao
    Lu, Qilin
    Tang, Lirong
    CELLULOSE, 2021, 28 (06) : 3409 - 3421
  • [2] Fabrication of quartz crystal microbalance humidity sensors based on super-hydrophilic cellulose nanocrystals
    Weixiang Chen
    Bo Chen
    Rixin Lv
    Milian Wu
    Jie Zhou
    Beili Lu
    Biao Huang
    Qilin Lu
    Lirong Tang
    Cellulose, 2021, 28 : 3409 - 3421
  • [3] Advances in quartz crystal microbalance relative humidity sensors: A review
    Chen, Qiao
    Yao, Yao
    Ao, Jin
    Yu, Xingling
    Wu, Decheng
    Shou, Mengjie
    Li, Rui
    Yang, Pingan
    MEASUREMENT, 2025, 243
  • [4] Electrospun Nanofibers for Quartz Crystal Microbalance Gas Sensors: A Review
    Rianjanu, Aditya
    Fauzi, Fika
    Triyana, Kuwat
    Wasisto, Hutomo Suryo
    ACS APPLIED NANO MATERIALS, 2021, 4 (10) : 9957 - 9975
  • [5] Self-assembled graphene oxide/polyethyleneimine films as high-performance quartz crystal microbalance humidity sensors
    Zhen Yuan
    Hui-Ling Tai
    Yuan-Jie Su
    Guang-Zhong Xie
    Xiao-Song Du
    Ya-Dong Jiang
    Rare Metals, 2021, 40 : 1597 - 1603
  • [6] Self-assembled graphene oxide/polyethyleneimine films as high-performance quartz crystal microbalance humidity sensors
    Zhen Yuan
    Hui-Ling Tai
    Yuan-Jie Su
    Guang-Zhong Xie
    Xiao-Song Du
    Ya-Dong Jiang
    Rare Metals, 2021, 40 (06) : 1597 - 1603
  • [7] Self-assembled graphene oxide/polyethyleneimine films as high-performance quartz crystal microbalance humidity sensors
    Yuan, Zhen
    Tai, Hui-Ling
    Su, Yuan-Jie
    Xie, Guang-Zhong
    Du, Xiao-Song
    Jiang, Ya-Dong
    RARE METALS, 2021, 40 (06) : 1597 - 1603
  • [8] Quartz Crystal Microbalance Humidity Sensors Based on Nanodiamond Sensing Films
    Yao, Yao
    Chen, Xiangdong
    Ma, Wenying
    Ling, Weiwei
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2014, 13 (02) : 386 - 393
  • [9] Quartz Crystal Microbalance Coated by PAN Nanofibers and PEDOT:PSS for Humidity Sensor
    Hidayat, Shidiq Nur
    Julian, Trisna
    Rianjanu, Aditya
    Kusumaatmadja, Ahmad
    Triyana, Kuwat
    Roto
    2017 INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM), 2017, : 119 - 123
  • [10] Cheap Quartz Crystal Microbalance humidity sensors based on Nafion® as sensing component
    Adamski, G.
    Godula, B.
    Kaluzynski, P.
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2018, 2018, 10808