Quantitative Analysis of Tear Film Fluorescence and Discomfort During Tear Film Instability and Thinning

被引:44
|
作者
Begley, Carolyn [1 ]
Simpson, Trefford [2 ]
Liu, Haixia [3 ]
Salvo, Eliza [1 ]
Wu, Ziwei [1 ]
Bradley, Arthur [1 ]
Situ, Ping [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON N2L 3G1, Canada
[3] Allergan Pharmaceut Inc, Irvine, CA 92715 USA
关键词
tear film instability; tear film break-up; tear film thinning; evaporation; fluorescein concentration quenching; corneal sensory nerves; nociception; DRY EYE DISEASE; OCULAR SURFACE; HYPEROSMOLAR STRESS; EPITHELIAL-CELLS; WORKSHOP; 2007; BREAK-UP; CORNEAL; EVAPORATION; PREVALENCE; SYMPTOMS;
D O I
10.1167/iovs.12-11299
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. METHODS. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. RESULTS. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r >= 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. CONCLUSIONS. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.
引用
收藏
页码:2645 / 2653
页数:9
相关论文
共 50 条
  • [31] Tear film, contact lenses and tear biomarkers
    Willcox, Mark D. P.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (04) : 350 - 363
  • [32] Effect of facemasks on the tear film during the COVID-19 pandemic
    Shalaby, Hisham Samy
    Eldesouky, Marwa Ebrahim ElSebaay
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 145 - 151
  • [33] In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain optical coherence tomography
    dos Santos, Valentin Aranha
    Schmetterer, Leopold
    Groeschl, Martin
    Garhofer, Gerhard
    Schmidl, Doreen
    Kucera, Martin
    Unterhuber, Angelika
    Hermand, Jean-Pierre
    Werkmeister, Rene M.
    OPTICS EXPRESS, 2015, 23 (16): : 21043 - 21063
  • [34] Effect of Glaucoma Medication in Tear Film Osmolarity of Patients Without Symptoms of Ocular Discomfort
    Halkiadakis, Ioannis
    Kontadakis, Georgios A.
    Tsiakou, Dimitra
    Patsea, Eleni
    Mitropoulos, Panagiotis
    Kandarakis, Artemios S.
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2015, 31 (06) : 330 - 334
  • [35] On tear film breakup (TBU): dynamics and imaging
    Braun, Richard J.
    Driscoll, Tobin. A.
    Begley, Carolyn G.
    King-Smith, P. Ewen
    Siddique, Javed I.
    MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA, 2018, 35 (02): : 145 - 180
  • [36] Assessment of Tear Film Anomalies in Childhood Obesity
    Bayat, Alper Halil
    Aydemir, Emre
    Aydemir, Gozde Aksoy
    Gencer, Hasim
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2022, 239 (03) : 331 - 337
  • [37] Assessment of Tear Film Optical Quality Dynamics
    Yu, A-Yong
    Lu, Ting
    Pan, An-Peng
    Lin, Duo-Ru
    Xu, Chen-Chen
    Huang, Jin-Hai
    Bao, Fang-Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (08) : 3821 - 3827
  • [38] The Effect of Low Humidity on the Human Tear Film
    Abusharha, Ali A.
    Pearce, E. Ian
    CORNEA, 2013, 32 (04) : 429 - 434
  • [39] Impact of environmental adaptation on tear film assessments
    Fagehi, R.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (03): : 231 - 237
  • [40] Knowledge and Use of Tear Film Evaluation Tests by Spanish Practitioners
    Cardona, Genis
    Seres, Carme
    Quevedo, Lluisa
    Auge, Montserrat
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (09) : 1106 - 1111