Quantitative Analysis of Tear Film Fluorescence and Discomfort During Tear Film Instability and Thinning

被引:44
|
作者
Begley, Carolyn [1 ]
Simpson, Trefford [2 ]
Liu, Haixia [3 ]
Salvo, Eliza [1 ]
Wu, Ziwei [1 ]
Bradley, Arthur [1 ]
Situ, Ping [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON N2L 3G1, Canada
[3] Allergan Pharmaceut Inc, Irvine, CA 92715 USA
关键词
tear film instability; tear film break-up; tear film thinning; evaporation; fluorescein concentration quenching; corneal sensory nerves; nociception; DRY EYE DISEASE; OCULAR SURFACE; HYPEROSMOLAR STRESS; EPITHELIAL-CELLS; WORKSHOP; 2007; BREAK-UP; CORNEAL; EVAPORATION; PREVALENCE; SYMPTOMS;
D O I
10.1167/iovs.12-11299
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. METHODS. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. RESULTS. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r >= 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. CONCLUSIONS. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.
引用
收藏
页码:2645 / 2653
页数:9
相关论文
共 50 条
  • [21] Efficacy of carbomer sodium hyaluronate trehalose vs hyaluronic acid to improve tear film instability and ocular surface discomfort after cataract surgery
    Caretti, L.
    Valerio, A. La Gloria
    Piermarocchi, R.
    Badin, G.
    Verzola, G.
    Masara, F.
    Scalora, T.
    Monterosso, C.
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1157 - 1163
  • [22] Mechanisms, imaging and structure of tear film breakup
    King-Smith, P. Ewen
    Begley, Carolyn G.
    Braun, Richard J.
    OCULAR SURFACE, 2018, 16 (01) : 4 - 30
  • [23] Assessment of tear secretion and tear film instability in cases with pterygium and normal subjects
    Roka, N.
    Shrestha, S. P.
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2013, 5 (01) : 16 - 23
  • [24] Effectiveness of Combined Tear Film Therapy in Patients with Evaporative Dry Eye with Short Tear Film Breakup Time
    Kim, Yung Hui
    Kang, Yeon Soo
    Lee, Hyo Seok
    Choi, Won
    You, In Cheon
    Yoon, Kyung Chul
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2017, 33 (08) : 635 - 643
  • [25] Analysis of tear film spatial instability for pediatric myopia under treatment
    Cho, Wan-Hua
    Fang, Po-Chiung
    Yu, Hun-Ju
    Lin, Pei-Wen
    Huang, Hsiu-Mei
    Kuo, Ming-Tse
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [26] Development of a rabbit model of tear film instability and evaluation of viscosity of artificial tear preparations
    Nakamura, S
    Okada, S
    Umeda, Y
    Saito, F
    CORNEA, 2004, 23 (04) : 390 - 397
  • [27] Assessment of Tear Film Quality among Smokers Using Tear Ferning Patterns
    Masmali, Ali M.
    Al-Shehri, Adil
    Alanazi, Saud A.
    Abusharaha, Ali
    Fagehi, Raied
    El-Hiti, Gamal A.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [28] Examining Tear Film Dynamics Using the Novel Tear Film Imager
    Mangwani-Mordani, Simran
    Baeza, Drew
    Acuna, Kelly
    Antman, Gal
    Harris, Alon
    Galor, Anat
    CORNEA, 2024, 43 (12) : 1547 - 1554
  • [29] On the Effect of Liquid Crystal Orientation in the Lipid Layer on Tear Film Thinning and Breakup
    M. J. Taranchuk
    R. J. Braun
    La Matematica, 2025, 4 (1): : 1 - 39
  • [30] Osmolality and tear film dynamics
    Stahl, Ulrike
    Willcox, Mark
    Stapleton, Fiona
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (01) : 3 - 11