A new sequence for single-shot diffusion-weighted NMR spectroscopy by the trace of the diffusion tensor

被引:30
作者
Valette, Julien [1 ,2 ,3 ]
Giraudeau, Celine [3 ]
Marchadour, Charlotte [1 ,2 ]
Djemai, Boucif [3 ]
Geffroy, Francoise [3 ]
Ghaly, Mohamed Ahmed [3 ]
Le Bihan, Denis [3 ]
Hantraye, Philippe [1 ,2 ]
Lebon, Vincent [1 ,2 ]
Lethimonnier, Franck [3 ]
机构
[1] CEA Fontenay Aux Roses, Inst Imagerie Biomed I2BM, Mol Imaging Res Ctr MIRCen, F-92265 Fontenay Aux Roses, France
[2] CNRS, Unite Rech Associee CEA CNRS 2210, F-92265 Fontenay Aux Roses, France
[3] CEA Saclay, NeuroSpin, CEA, Inst Imagerie Biomed I2BM, F-91191 Gif Sur Yvette, France
关键词
diffusion; spectroscopy; cross-terms; anisotropy; MAGNETIC-RESONANCE-SPECTROSCOPY; RAT-BRAIN; IN-VIVO; INTRACELLULAR METABOLITES; H-1-NMR SPECTROSCOPY; MR SPECTROSCOPY; SELF-DIFFUSION; LIPID DROPLETS; VISIBLE LIPIDS; SPIN-ECHO;
D O I
10.1002/mrm.24193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-weighted spectroscopy is a unique tool for exploring the intracellular microenvironment in vivo. In living systems, diffusion may be anisotropic, when biological membranes exhibit particular orientation patterns. In this work, a volume selective diffusion-weighted sequence is proposed, allowing single-shot measurement of the trace of the diffusion tensor, which does not depend on tissue anisotropy. With this sequence, the minimal echo time is only three times the diffusion time. In addition, cross-terms between diffusion gradients and other gradients are cancelled out. An adiabatic version, similar to localization by adiabatic selective refocusing sequence, is then derived, providing partial immunity against cross-terms. Proof of concept is performed ex vivo on chicken skeletal muscle by varying tissue orientation and intra-voxel shim. In vivo performance of the sequence is finally illustrated in a U87 glioblastoma mouse model, allowing the measurement of the trace apparent diffusion coefficient for six metabolites, including J-modulated metabolites. Although measurement performed along three separate orthogonal directions would bring similar accuracy on trace apparent diffusion coefficient under ideal conditions, the method described here should be useful for probing intimate properties of the cells with minimal experimental bias. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1705 / 1712
页数:8
相关论文
共 29 条
[1]  
Barba I, 1999, CANCER RES, V59, P1861
[2]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[3]   Single-shot diffusion trace 1H NMR spectroscopy [J].
de Graaf, RA ;
Braun, KPJ ;
Nicolay, K .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :741-748
[4]   Changes in the diffusion of water and intracellular metabolites after excitotoxic injury and global ischemia in neonatal rat brain [J].
Dijkhuizen, RM ;
de Graaf, RA ;
Tulleken, KAF ;
Nicolay, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (03) :341-349
[5]  
Dreher W, 2001, MAGN RESON MED, V45, P383, DOI 10.1002/1522-2594(200103)45:3<383::AID-MRM1050>3.0.CO
[6]  
2-G
[7]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[8]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811
[9]  
Hakumäki JM, 1998, CANCER RES, V58, P3791
[10]   1H NMR visible lipids in the life and death of cells [J].
Hakumäki, JM ;
Kauppinen, RA .
TRENDS IN BIOCHEMICAL SCIENCES, 2000, 25 (08) :357-362