Contribution of blood viscosity in the assessment of flow-mediated dilation and arterial stiffness

被引:23
|
作者
Parkhurst, Kristin L. [1 ]
Lin, Hsin-Fu [1 ]
DeVan, Allison E. [1 ]
Barnes, Jill N. [1 ]
Tarumi, Takashi [1 ]
Tanaka, Hirofumi [1 ]
机构
[1] Univ Texas Austin, Dept Kinesiol & Hlth Educ, Cardiovasc Aging Res Lab, Austin, TX 78712 USA
关键词
carotid artery compliance; pulse wave velocity; shear rate; shear stress; CARDIOVASCULAR RISK-FACTORS; PLASMA VISCOSITY; CIGARETTE-SMOKING; BRACHIAL-ARTERY; PRESSURE; HYPERVISCOSITY; VASODILATION; HYPERTENSION; ASSOCIATION; POPULATION;
D O I
10.1177/1358863X12450095
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Flow-mediated dilation (FMD) is a non-invasive index of endothelial function. In an attempt to standardize FMD for shear stimulus, shear rate (velocity/diameter), rather than shear stress (viscosity*velocity/diameter), is commonly used as a surrogate measure, although it is limited by individual differences in blood viscosity. The purpose of this study was to determine the contribution of whole blood viscosity to FMD and other key measures of vascular function. Blood viscosity, FMD, carotid artery compliance, and carotid-femoral pulse wave velocity (cfPWV) were measured in 98 apparently healthy adults varying widely in age (18-63 years). Whole blood viscosity was not significantly correlated with FMD, cfPWV, or carotid artery compliance. Shear rate was a stronger correlate with FMD than shear stress that takes blood viscosity into account (r = 0.43 vs 0.28). No significant differences were observed between whole blood viscosity and traditional risk factors for cardiovascular disease. Age was positively correlated with cfPWV (r = 0.65, p < 0.001) and negatively correlated with FMD (r = -0.24, p < 0.05) and carotid artery compliance (r = -0.45, p < 0.01). Controlling for viscosity did not reduce the strength of these relations. These results indicate that whole blood viscosity does not significantly impact measures of vascular function and suggests that the common practice to use shear rate, rather than shear stress, in the adjustment of FMD is valid.
引用
收藏
页码:231 / 234
页数:4
相关论文
共 50 条
  • [1] Changes of Arterial Stiffness during Flow-mediated Dilation Procedure
    Hashuro, Muhammad Shiddiq Sayyid
    Zakaria, Hasballah
    Mengko, Tati L. R.
    2015 4TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, COMMUNICATIONS, INFORMATION TECHNOLOGY, AND BIOMEDICAL ENGINEERING (ICICI-BME), 2015, : 32 - 35
  • [2] Evaluation of Arterial Stiffness During the Flow-Mediated Dilation Test
    Hirano, Harutoyo
    Kihara, Daisuke
    Hirano, Hiroki
    Kurita, Yuichi
    Ukawa, Teiji
    Takayanagi, Tsuneo
    Morimoto, Haruka
    Nakamura, Ryuji
    Saeki, Noboru
    Higashi, Yukihito
    Kawamoto, Masashi
    Yoshizumi, Masao
    Tsuji, Toshio
    2013 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2013), 2013, : 3756 - 3759
  • [3] Blood viscosity but not shear stress associates with delayed flow-mediated dilation
    Irace, Concetta
    Tripolino, Cesare
    Scavelli, Faustina
    Messiniti, Valentina
    Tassone, Bruno
    Della Valle, Elisabetta
    Carallo, Claudio
    Gnasso, Agostino
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2015, 115 (04) : 747 - 753
  • [4] Blood viscosity but not shear stress associates with delayed flow-mediated dilation
    Concetta Irace
    Cesare Tripolino
    Faustina Scavelli
    Valentina Messiniti
    Bruno Tassone
    Elisabetta Della Valle
    Claudio Carallo
    Agostino Gnasso
    European Journal of Applied Physiology, 2015, 115 : 747 - 753
  • [5] Ultrasound Assessment of Flow-Mediated Dilation
    Harris, Ryan A.
    Nishiyama, Steven K.
    Wray, D. Walter
    Richardson, Russell S.
    HYPERTENSION, 2010, 55 (05) : 1075 - 1085
  • [6] Blood flow simulation during flow-mediated dilation
    Asami, Naoya
    Yamazaki, Yoichi
    Kamiyama, Yoshimi
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2018, 101 (08) : 19 - 26
  • [7] Blood flow simulation during flow-mediated dilation
    Asami N.
    Yamazaki Y.
    Kamiyama Y.
    IEEJ Transactions on Electronics, Information and Systems, 2018, 138 (03) : 221 - 227
  • [8] Blood Flow Patterns during Flow-Mediated Dilation
    Morales-Acuna, Francisco
    Valencia, Carolina
    Gurovich, Alvaro N.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 489 - 489
  • [9] Flow-Mediated Arterial Dilation in Primary Antiphospholipid Syndrome
    Bilora, Franca
    Sartori, Maria Teresa
    Zanon, Ezio
    Campagnolo, Enrico
    Arzenton, Marianna
    Rossato, Alberto
    ANGIOLOGY, 2009, 60 (01) : 104 - 107
  • [10] The association of arterial shear and flow-mediated dilation in diabetes
    Gibbs, Bethany Barone
    Dobrosielski, Devon A.
    Lima, Michael
    Bonekamp, Susanne
    Stewart, Kerry J.
    Clark, Jeanne M.
    VASCULAR MEDICINE, 2011, 16 (04) : 267 - 274