A simple, rapid and low cost reversed-phase dispersive liquid-liquid microextraction for the determination of Na, K, Ca and Mg in biodiesel

被引:38
作者
Lourenco, Emilene C. [1 ]
Eyng, Eduardo [1 ]
Bittencourt, Paulo R. S. [1 ]
Duarte, Fabio A. [2 ]
Picoloto, Rochele S. [2 ]
Flores, Eder L. M. [1 ]
机构
[1] Univ Tecnol Fed Parana, Dept Quim, Campus Medianeira, Medianeira, PR, Brazil
[2] Univ Fed Santa Maria, Dept Quim, Santa Maria, RS, Brazil
关键词
Biodiesel; Metals; Microextraction; RP-DLLME; Flame atomic absorption spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; EDIBLE OILS; F AAS; FLAME; EXTRACTION; PRECONCENTRATION; CADMIUM;
D O I
10.1016/j.talanta.2019.02.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work a method based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) as sample preparation for the extraction and preconcentration of Na, K, Ca and Mg in biodiesel samples was developed. The analytes determination was performed by flame atomic absorption spectrometry (FAAS), operating in emission mode for Na and K and in absorption mode for Ca and Mg. The extraction/preconcentration step of the analytes was performed by using a mixture of dispersant and extractant solvents (isopropanol and HNO3, respectively) and the aqueous phase containing the analytes was separated by centrifugation. Some parameters such as sample mass, type and volume of dispersant and extractant solutions, HNO3 concentration (extraction solution), use of ultrasound, centrifugation time and temperature were evaluated. During the optimization of RP-DLLME, biodiesel samples were spiked with a multi-element biodiesel B100 (Conostan(center dot)) with final concentration of 1.0 mu g g(-1) of the analytes. Analytes determination was performed by FAAS using external calibration with aqueous reference solutions. The limits of quantification (LOQ) for Na, K, Ca and Mg were 0.04; 0.02; 0.05 and 0.08 mu g kg respectively. The accuracy was evaluated by recovery tests, which ranged from 93.9% to 108.1%, with relative standard deviation lower than 3% for all analytes. Then, the proposed method was applied for analytes determination in five biodiesel samples produced from different raw materials. Comparing to conventional methods for elements determination in biodiesel (e.g., dilution with organic solvent, sample digestion, etc.), RP-DLLME combined to FAAS is simple, low cost, low reagents consumption and provides LOQs values significantly below compared to the limits established in the legislation for these elements in biodiesel.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 27 条
  • [1] [Anonymous], 2010, D675110 ASTM
  • [2] Bart JCJ, 2010, WOODHEAD PUBL SER EN, P1, DOI 10.1533/9781845697761
  • [3] Biodiesel as an alternative motor fuel: Production and policies in the European Union
    Bozbas, Kahraman
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (02) : 542 - 552
  • [4] Capote F. P., 2007, TECHNIQUES INSTRUMEN, V26
  • [5] Monitoring oxidative stability and phenolic compounds composition of myrtle-enriched extra virgin olive during heating treatment by flame, oven and microwave using reversed phase dispersive liquid-liquid microextraction (RP-DLLME)-HPLC-DAD-FLD method
    Dairi, S.
    Galeano-Diaz, T.
    Acedo-Valenzuela, M. I.
    Godoy-Caballero, M. P.
    Dahmoune, F.
    Remini, H.
    Madani, K.
    [J]. INDUSTRIAL CROPS AND PRODUCTS, 2015, 65 : 303 - 314
  • [6] Determination of Na, K, Mg and Ca in Biodiesel by LS F AAS and HR-CS F AAS: Studies that Supported the Proposal of the ABNT NBR 15556 Norm
    de Oliveira, Ligia C. C.
    Vieira, Mariana A.
    Ribeiro, Anderson S.
    Baptista, Paula M.
    Goncalves, Rodrigo A.
    de Campos, Reinaldo C.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (07) : 1400 - +
  • [7] Dispersive liquid-liquid microextraction for chemical speciation and determination of ultra-trace concentrations of metal ions
    El-Shahawi, M. S.
    Al-Saidi, H. M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 44 : 12 - 24
  • [8] A practical guide to analytical method validation, including measurement uncertainty and accuracy profiles
    Gustavo Gonzalez, A.
    Angeles Herrador, M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) : 227 - 238
  • [9] Reversed-phase dispersive liquid-liquid microextraction with central composite design optimization for preconcentration and HPLC determination of oleuropein
    Hashemi, Payman
    Raeisi, Fatemeh
    Ghiasvand, Ali Reza
    Rahimi, Akram
    [J]. TALANTA, 2010, 80 (05) : 1926 - 1931
  • [10] Iqbal J., 2010, The Open Analytical Chemistry J, V4, P18, DOI [10.2174/1874065001004010018, DOI 10.2174/1874065001004010018]