Application of inductively coupled plasma mass spectrometry to phospholipid analysis

被引:38
作者
Kovacevic, M
Leber, R
Kohlwein, SD
Goessler, W
机构
[1] Karl Franzens Univ Graz, Inst Chem Analyt Chem, A-8010 Graz, Austria
[2] Natl Inst Chem, SI-1000 Ljubljana, Slovenia
[3] Karl Franzens Univ Graz, Inst Mol Biol Biochem & Microbiol, A-8010 Graz, Austria
关键词
D O I
10.1039/b307545a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Phospholipids are the main constituents of membranes in all types of prokaryotic and eukariotic cells. Due to their complexity and heterogeneity in biological samples, qualitative and quantitative analyses of membrane phospholipids in cellular extracts represent major analytical challenges, mainly due to suitable and sensitive detection methods. The inductively coupled plasma mass spectrometer (ICP-MS) is a suitable detector for selective determination of phospholipids as they all contain phosphorus. Phospholipids are extractable with organic solvents, therefore liquid chromatography with an organic mobile phase was used for separation of different lipid species. Solvent load to the plasma was reduced by splitting the mobile phase prior to reaching the nebulizer, by chilling the spray chamber to -5 degreesC and by optimisation of carrier gas flow for maximum condensation of organic vapours. Despite desolvation, oxygen was added to prevent carbon deposition on interface cones. To reduce polyatomic interferences at m/z ratio 31 (e.g. (CH3O+)-C-31) and to improve detection limits, helium was used as a collision gas. The achieved absolute detection limits were between 0.21 and 1.2 ng of phosphorus and were superior to those obtained by an evaporative light scattering detector, which provides an alternative detection system for lipid analysis. The usefulness of the developed method was demonstrated by analysis of lipid extracts from the yeast Saccharomyces cerevisiae.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 25 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHOSPHATIDIC-ACID [J].
ABIDI, SL ;
MOUNTS, TL .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 671 (1-2) :281-297
[2]   The potential of inductively coupled plasma mass spectrometry detection for high-performance liquid chromatography combined with accurate mass measurement of organic pharmaceutical compounds [J].
Axelsson, BO ;
Jörnten-Karlsson, M ;
Michelsen, P ;
Abou-Shakra, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) :375-385
[3]   Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1497-1502
[4]   Quantitative analysis of biological membrane lipids at the low picomole level by nano-electrospray ionization tandem mass spectrometry [J].
Brugger, B ;
Erben, G ;
Sandhoff, R ;
Wieland, FT ;
Lehmann, WD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (06) :2339-2344
[5]  
CEVC G, 1993, PHISPHOLIPIDS HDB, P23
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF WHEAT-FLOUR LIPIDS USING AN EVAPORATIVE LIGHT-SCATTERING DETECTOR [J].
CONFORTI, FD ;
HARRIS, CH ;
RINEHART, JT .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :83-88
[7]   DETERMINATION OF PHOSPHATIDYLCHOLINE, PHOSPHATIDYLGLYCEROL AND THEIR LYSO FORMS FROM LIPOSOME DISPERSIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING HIGH-SENSITIVITY REFRACTIVE-INDEX DETECTION [J].
GRIT, M ;
CROMMELIN, DJA ;
LANG, J .
JOURNAL OF CHROMATOGRAPHY, 1991, 585 (02) :239-246
[8]   Specific detection and quantification of palmitoyl-stearoyl-phosphatidylserine in human blood using normal-phase liquid chromatography coupled with electrospray mass spectrometry [J].
Hvattum, E ;
Larsen, Å ;
Uran, S ;
Michelsen, PM ;
Skotland, T .
JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2) :47-56
[9]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION FOR PHOSPHORUS AND SULFUR-COMPOUNDS SEPARATED BY LIQUID-CHROMATOGRAPHY [J].
JIANG, SJ ;
HOUK, RS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (4-5) :405-411
[10]   APPLICATION OF THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY FOR THE DETERMINATION OF PHOSPHOLIPIDS AND RELATED-COMPOUNDS [J].
KIM, HY ;
SALEM, N .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :722-726