Assessment of Fetal Congenital Heart Diseases by 4-Dimensional Ultrasound Using Spatiotemporal Image Correlation: Pictorial Review

被引:16
作者
Araujo Junior, Edward [1 ]
Tonni, Gabriele [2 ]
Bravo-Valenzuela, Nathalie Jeanne [1 ]
Costa, Fabricio Da Silva [3 ]
Meagher, Simon [3 ]
机构
[1] Fed Univ Sao Paulo EPM UNIFESP, Dept Obstet, Paulista Sch Med, Sao Paulo, Brazil
[2] AUSL Reggio Emilia, Guastalla Civil Hosp, Dept Obstet & Gynecol, Reggio Emilia, Italy
[3] Monash Ultrasound Women, Clayton, Vic, Australia
关键词
3D/4D ultrasound; fetal echocardiogram; inversion mode; spatiotemporal image correlation; VENTRICULAR SEPTAL-DEFECT; PRENATAL-DIAGNOSIS; INVERSION MODE; B-FLOW; CORRELATION TECHNOLOGY; PULMONARY-ATRESIA; WEEKS GESTATION; INTERNET LINK; ECHOCARDIOGRAPHY; ULTRASONOGRAPHY;
D O I
10.1097/RUQ.0000000000000328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this pictorial review is to describe the technical advances achieved through the application of 4-dimensional (4D) ultrasound using spatiotemporal image correlation (STIC) over conventional 2-dimensional ultrasound in the prenatal detection of congenital heart disease (CHD). Spatiotemporal image correlation is a volume imaging technique that simplifies fetal heart studies while providing more diagnostic information than is typically available from traditional 2-dimensional studies. Four-dimensional software allows the study of cardiac anatomy and function during a single cardiac cycle and has greatly contributed to diagnostic enhancement of CHD. Color flow and power Doppler can be added to STIC in the study of vessel anatomy and to increase the detection of ventricular septal defects. Anatomical details of the fetus can be displayed in multiple images such as using computed tomography or magnetic resonance imaging. In addition, cardiac anatomy can be sectioned freely and reconstructed using different reformatting applications. Realistic views of the fetal heart, with particular emphasis on myocardium and endocardium cushion, can be reached using novel lightening techniques. Moreover, using 4D ultrasound, echolucent structures can be converted into solid voxels generating digital casts of the fetal heart that enhances the understanding of the great vessel relationships in the ventricular inflow and outflow tracts. Recently, sillhouette mode has shown to improve depth perception and resolution compared with conventional 3D power Doppler in the study of inflow and outflow tracts. Here, a gallery of prenatally detected CHD using 4D ultrasound with STIC and different applications is described.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 41 条
[1]   Four-Dimensional Power Doppler Sonography With the HDlive Silhouette Mode in Antenatal Diagnosis of a Right Aortic Arch With an Aberrant Left Subclavian Artery [J].
AboEllail, Mohamed Ahmed Mostafa ;
Kanenishi, Kenji ;
Tenkumo, Chiaki ;
Mori, Nobuhiro ;
Katayama, Tomihiro ;
Koyano, Kosuke ;
Kusaka, Takashi ;
Hata, Toshiyuki .
JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (03) :661-U663
[2]   Accuracy of four-dimensional spatiotemporal image correlation echocardiography in the prenatal diagnosis of congenital heart defects [J].
Bennasar, M. ;
Martinez, J. M. ;
Gomez, O. ;
Bartrons, J. ;
Olivella, A. ;
Puerto, B. ;
Gratacos, E. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) :458-464
[3]   Feasibility and accuracy of fetal echocardiography using four-dimensional spatiotemporal image correlation technology before 16 weeks' gestation [J].
Bennasar, M. ;
Martinez, J. M. ;
Olivella, A. ;
Del Rio, M. ;
Gomez, O. ;
Figueras, F. ;
Puerto, B. ;
Gratacos, E. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (06) :645-651
[4]   Accuracy of prenatal diagnosis of congenital heart defects [J].
Berghella, V ;
Pagotto, L ;
Kaufman, M ;
Huhta, JC ;
Wapner, RJ .
FETAL DIAGNOSIS AND THERAPY, 2001, 16 (06) :407-412
[5]   Three- and four-dimensional volume-rendered imaging of fetal double-outlet right ventricle using inversion mode [J].
Dai, S. -Y. ;
Inubashiri, E. ;
Hanaoka, U. ;
Kanenishi, K. ;
Yamashiro, C. ;
Tanaka, H. ;
Yanagihara, T. ;
Hata, T. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (03) :347-349
[6]   Extended field-of-view and B-flow ultrasound: fashion or future? [J].
Deane, C .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 15 (02) :96-97
[7]   Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart [J].
DeVore, GR ;
Falkensammer, P ;
Sklansky, MS ;
Platt, LD .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (04) :380-387
[8]   Evaluation of normal fetal pulmonary veins from the early second trimester by enhanced-flow (e-flow) echocardiography [J].
Dong, F. -Q. ;
Zhang, Y. -H. ;
Li, Z. -A. ;
Hou, Z. -Z. ;
He, X. -J. ;
Guo, Y. -Z. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (06) :652-657
[9]   A novel method to improve prenatal diagnosis of abnormal systemic venous connections using three- and four-dimensional ultrasonography and 'inversion mode" [J].
Epsinoza, J ;
Gonçalves, LF ;
Lee, W ;
Mazor, M ;
Romero, R .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (05) :428-434
[10]   Accuracy of Fetal Echocardiography in the Differential Diagnosis between Truncus Arteriosus and Pulmonary Atresia with Ventricular Septal Defect [J].
Gomez, Olga ;
Soveral, Iris ;
Bennasar, Mar ;
Crispi, Fatima ;
Masoller, Narcis ;
Marimon, Edda ;
Bartrons, Joaquim ;
Gratacos, Eduard ;
Martinez, Josep M. .
FETAL DIAGNOSIS AND THERAPY, 2016, 39 (02) :90-99