Maximum power extraction and DC-Bus voltage regulation in grid-connected PV/BES system using modified incremental inductance with a novel inverter control

被引:12
作者
AL-Wesabi, Ibrahim [1 ,2 ,3 ]
Zhijian, Fang [1 ,2 ,3 ]
Farh, Hassan M. Hussein [4 ]
Al-Shammaa, Abdullrahman A. [4 ]
Dong, Hanlin [1 ,2 ,3 ]
Al-Shaalan, Abdullah M. [5 ]
Kandil, Tarek [6 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[2] Hubei Key Lab Adv Control & Intelligent Automat, Wuhan 430074, Peoples R China
[3] Minist Educ, Engn Res Ctr Intelligent Technol Geo Explorat, Wuhan 430074, Peoples R China
[4] Imam Mohammad Ibn Saud Islamic Univ, Coll Engn, Elect Engn Dept, Riyadh, Saudi Arabia
[5] King Saud Univ, Coll Engn, Elect Engn Dept, Riyadh, Saudi Arabia
[6] Western Carolina Univ, Sch Engn & Technol, Cullowhee, NC 28723 USA
关键词
POINT TRACKING; CONDUCTANCE MPPT; CONVERTER; ENERGY; RECTIFIER; ALGORITHM;
D O I
10.1038/s41598-022-22952-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Low ripples and variations in the DC-Bus voltage in single-phase Photovoltaic/Battery Energy Storage (PV/BES) grid-connected systems may cause significant harmonics distortion, instability, and reduction in power factor. The use of short-life electrolytic capacitor on the DC-Bus is considered a standard way for reducing these ripples and variations because of its large capacitance but results in short lifetime of the inverter. Replacing large electrolytic capacitors with small film capacitors can extend the lifetime of a PV/BES grid-connected system because small film capacitors have longer lifetime than large electrolytic capacitors. These film capacitors have low capacitance, which causes severe oscillations in the output current, and voltage drop due to huge ripples on the DC-Bus voltage. In this research, the main goal is to eliminate the output current ripples and voltage fluctuations associated with employing film capacitors. First, a modified incremental conductance (MIC) technique is proposed for tracking the maximum power by controlling the duty ratio of the DC-DC boost converter. Second, for the first time, a simple and novel d-q current regulation technique, which employs flowchart decision logic, is used in the DC-Bus control system for both the PV power system and the state of charge (SOC) of the BES. In this case, the DC-Bus controller is characterized by a cost-effective implementation because of its low sampling frequency. Although the presented approaches are successful in eliminating voltage distortion and fluctuations, they have unacceptable dynamic performance. Therefore, to improve the dynamic performance, BES was used to maintain a reliable and stable harvest from PV modules for varying loads while also increasing the dynamic performance of the overall system. The proposed PV/BES grid-connected systems, which employs a small 10-mu F bus capacitor, is simulated and connected to the grid (230 V, 50 Hz). The DC-Bus voltage overshoot, undershoot and the total harmonics distortion (THD) of the output current for the proposed MIC are (1 V), (2.5 V) and (less than 5%), respectively. The average time response under rising radiation to track the global peak for MIC, traditional incremental conductance and variable step size incremental conductance are 1.403 s, 1.501 s and 1.113 s respectively. The obtained findings demonstrated the efficacy and superiority of the proposed d-q current control and MIC technique.
引用
收藏
页数:21
相关论文
共 40 条
[1]   Direct Sliding Mode Control for Dynamic Instabilities in DC-Link Voltage of Standalone Photovoltaic Systems with a Small Capacitor [J].
Al-Wesabi, Ibrahim ;
Fang, Zhijian ;
Wei, Zhiguo ;
Dong, Hanlin .
ELECTRONICS, 2022, 11 (01)
[2]   Study of the MPP tracking algorithms: Focusing the numerical method techniques [J].
Amir, A. ;
Amir, A. ;
Selvaraj, J. ;
Rahim, N. A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 62 :350-371
[3]  
Bahraini F., 2020 11 POWER ELECT, P1
[4]   Photovoltaic maximum power point tracking under fast varying of solar radiation [J].
Belkaid, A. ;
Colakc, I. ;
Isik, O. .
APPLIED ENERGY, 2016, 179 :523-530
[5]  
Chen BC, 2011, C IND ELECT APPL, P1621, DOI 10.1109/ICIEA.2011.5975850
[6]   An Optimal Control Strategy for DC Bus Voltage Regulation in Photovoltaic System with Battery Energy Storage [J].
Daud, Muhamad Zalani ;
Mohamed, Azah ;
Hannan, M. A. .
SCIENTIFIC WORLD JOURNAL, 2014,
[7]   Grade point average assessment for metaheuristic GMPP techniques of partial shaded PV systems [J].
Eltamaly, Ali M. ;
Farh, Hassan M. H. ;
Al-Saud, Mamdooh S. .
IET RENEWABLE POWER GENERATION, 2019, 13 (08) :1215-1231
[8]   Dynamic global maximum power point tracking of the PV systems under variant partial shading using hybrid GWO-FLC [J].
Eltamaly, Ali M. ;
Farh, Hassan M. H. .
SOLAR ENERGY, 2019, 177 :306-316
[9]   A novel evaluation index for the photovoltaic maximum power point tracker techniques [J].
Eltamaly, Ali M. ;
Farh, Hassan M. H. ;
Othman, Mohd F. .
SOLAR ENERGY, 2018, 174 :940-956
[10]   A novel sizing inherits allocation strategy of renewable distributed generations using crow search combined with particle swarm optimization algorithm [J].
Farh, Hassan M. H. ;
Eltamaly, Ali M. ;
Al-Shaalan, Abdullah M. ;
Al-Shamma'a, Abdullrahman A. .
IET RENEWABLE POWER GENERATION, 2021, 15 (07) :1436-1450